Instrument: Equilibrator Inlet Mass Spectrometer

Instrument Short Name: EIMS
Instrument Description:

Cassar N, Barnett BA, Bender ML, Kaiser J, Hamme RC, Tilbrook B., Continuous high-frequency dissolved O2/Ar measurements by equilibrator inlet mass spectrometry. Anal Chem. 2009 Mar 1;81(5):1855-64. doi: 10.1021/ac802300u. 

Source: Department of Geosciences, Princeton University, Princeton, New Jersey 08544, USA. ncassar@princeton.edu

Abstract
The oxygen (O(2)) concentration in the surface ocean is influenced by biological and physical processes. With concurrent measurements of argon (Ar), which has similar solubility properties as oxygen, we can remove the physical contribution to O(2) supersaturation and determine the biological oxygen supersaturation. Biological O(2) supersaturation in the surface ocean reflects the net metabolic balance between photosynthesis and respiration, i.e., the net community productivity (NCP). We present a new method for continuous shipboard measurements of O(2)/Ar by equilibrator inlet mass spectrometry (EIMS). From these measurements and an appropriate gas exchange parametrization, NCP can be estimated at high spatial and temporal resolution. In the EIMS configuration, seawater from the ship's continuous intake flows through a cartridge enclosing a gas-permeable microporous membrane contactor. Gases in the headspace of the cartridge equilibrate with dissolved gases in the flowing seawater. A fused-silica capillary continuously samples headspace gases, and the O(2)/Ar ratio is measured by mass spectrometry. The ion current measurements on the mass spectrometer reflect the partial pressures of dissolved gases in the water flowing through the equilibrator. Calibration of the O(2)/Ar ion current ratio (32/40) is performed automatically every 2 h by sampling ambient air through a second capillary. A conceptual model demonstrates that the ratio of gases reaching the mass spectrometer is dependent on several parameters, such as the differences in molecular diffusivities and solubilities of the gases. Laboratory experiments and field observations performed by EIMS are discussed. We also present preliminary evidence that other gas measurements, such as N(2)/Ar and pCO(2) measurements, may potentially be performed with EIMS. Finally, we compare the characteristics of the EIMS with the previously described membrane inlet mass spectrometry (MIMS) approach.

PMID: 19193192 [PubMed - indexed for MEDLINE]

PI supplied instrument name: Equilibrator Inlet Mass Spectrometer
Dataset-specific description

Continuous analysis of oxygen/argon ratios by equilibrator inlet mass spectrometry (EIMS)

Liquicel equilibrator cartridge - Equilibrator cartridge is Membrana LiquiCel MicroModule G569 with flow-through water but only one air-side inlet/outlet.