| Contributors | Affiliation | Role |
|---|---|---|
| Hatcher, Patrick G. | Old Dominion University (ODU) | Principal Investigator |
| Goranov, Aleksandar I. | Old Dominion University (ODU) | Co-Principal Investigator |
| Pearson, Ann | Harvard University | Co-Principal Investigator |
| Chen, Hongmei | Old Dominion University (ODU) | Scientist |
| Aguilar-Martinez, Scarlet Z. | Old Dominion University (ODU) | Student |
| Mickle, Audrey | Woods Hole Oceanographic Institution (WHOI BCO-DMO) | BCO-DMO Data Manager |
Vanillin (Acros, 99%), a lignin monophenol, was chosen as a representative monomeric unit of lignin, a major component of tDOM (Opsahl and Benner, 1998). A solution of 20 mg-C of vanillin in 1 L ultrapure MilliQ water was prepared to serve as a stock solution in photochemical experiments. This concentration was chosen because it is representative to carbon contents in upstream terrestrial aquatic environments such as rivers and lakes (Gonsior et al., 2009).
Photo-irradiation. Approximately 350 mL of vanillin stock solution was aliquoted into a pre-combusted 500 mL quartz round-bottom flask capped with a pre-combusted glass cap. An aliquot of the stock solution was immediately wrapped with aluminum foil and stored at room temperature as a dark control. Another aliquot of the stock solution was frozen to evaluate the stability of the dark control at room temperature. Up to three 500 mL quartz flasks were placed in a flatbed SUNTEST CPS+ solar simulator equipped with a daylight UV glass filter (ATLAS Cat. No. 56052371, cutoff at ~290 nm) for simulating solar radiation outdoors. Irradiation was performed under controlled chamber air temperature of 35 °C in 24-hour cycles using power of 250 W/m2 yielding ~21,600 kJ/m2 per 24 hours. Flasks were irradiated for 24 hours and then opened for 30 minutes during which they were aerated and gently stirred. During this aeration step, a 20-, 40-, or 50-mL subsample was taken out for analyses. To keep the same total volume throughout the irradiation (350 mL), the same amount of ultrapure water was added back. Multiple irradiation experiments were performed to yield sufficient sample volumes for the different analytical methods employed for the characterization of the photo-products.
Dissolved organic carbon. Dissolved organic matter was quantified as dissolved organic carbon (DOC) equivalents (in mg-C/L) on a Shimadzu TOC-VCPH instrument following standard operating procedures. Briefly, samples were acidified and sparged with air for 3 minutes to remove any inorganic carbon species (dissolved CO, CO2, HCO3-, CO32-) or other dissolved volatile gases (e.g., CH4). Then, samples were injected in a high temperature combustion reactor (720 ˚C) to oxidize the DOM to CO2. Detection of CO2 is achieved using a non-dispersive infrared detector. DOC concentrations were quantified using standard calibration curves made with potassium hydrogen phthalate (Nacalai Tesque, JIS special grade).
Stable carbon isotopic composition (δ13C). Photo-irradiated solutions of vanillin were aliquoted to Falcon® tubes that were pre-aged in 2 % (w/w) NaOH for one month to remove any leachable carbon. Samples were freeze-dried and resuspended in ultrapure water to yield concentrated solutions necessary for analysis on a spooling-wire microcombustion (SWiM) device (Sessions et al. 2005) interfaced with an isotope-ratio mass spectrometer (IRMS) to determine the ratio of 13C to 12C atoms expressed in a delta notation (δ13C) and referenced to Vienna Pee Dee Belemnite (Camin et al. 2025).
The SWiM system used has been employed previously to measure δ¹³C values of aqueous samples (Mohr et al. 2014). The SWiM interface is connected to a ThermoFinnigan DeltaPlus Advantage IRMS via an open split. Reference CO₂ is controlled using a Conflo III, and data are collected and analyzed using Isodat v3.0. Each analytical run begins with three pulses of standard CO₂ reference gas and ends with two pulses of standard CO₂ reference gas. Samples were injected in 1 μL aliquots, separated by 30 sec; 3 to 5 injections are made of each sample. All data are corrected assuming linear drift of the m/z 45/44 ratio over the duration of the run. Each run includes samples (unknowns) and standard dilution series of two laboratory reference materials (dextrose, -11.2‰, and nor-leucine, -27.7‰). Empty tube blanks containing ultrapure water are also measured. Directly measured blank δ¹³C values were smaller than values inferred from the dilution series, determined by the intersection of δ¹³C versus Area-1 for the two dilution series, which intersect at Area-1 and δ¹³C of the blank. All samples were subsequently blank-corrected using the intersection of these two lines.
pH. pH measurements were performed using a Thermo Orion Star Series benchtop conductivity meter on unirradiated and irradiated vanillin solutions. The pH meter was calibrated daily with pH 4.01 buffer solution (YSI 3821), pH 7.00 buffer solution (YSI 3822), and pH 10.00 buffer solution (YSI 3823).
Condensed aromatic carbon (ConAC). Exactly 40 mL of vanillin control and photochemically processed samples were freeze-dried. The obtained residue was redissolved in 2 mL of 1:1 methanol:water and transferred to 2-mL glass ampules. The solvent was evaporated at 60 °C and the residue was mixed with 0.5 mL concentrated nitric acid (65 %). Ampoules were flame-sealing and then samples were digested in an oven at 160°C for 6 hours. After this thermal digestion, the nitric acid was evaporated at 70°C in a sand bath under a stream of ultrapure nitrogen. The residue was redissolved in 0.5 mL of 0.6 mol L⁻¹ H₃PO₄ and filtered through a 0.2 µm syringe filter (Thermo Scientific™ Titan3™ PTFE). Benzenepentacarboxylic acid (B5CA, C₁₁H₆O₁₀) and benzenehexacarboxylic acid (B6CA, C₁₂H₆O₁₂) were quantified using an Agilent 1100 high-performance liquid chromatography system (Wagner et al. 2017). Their concentrations were then converted to carbon concentrations (i.e., B6CAC and B5CAC) and used to estimate the ConAC content of the original sample prior to digestion by multiplying by a scaling factor of 7.04 (Bostick et al., 2018) followed by normalization to organic carbon content. The molar ratio of B6CA to B5CA was also calculated to serve as an indicator of the degree of condensation of ConAC.
Carboxyl-rich alicyclic molecules (CRAM). Carboxyl-rich alicyclic molecules (CRAM) were quantified using liquid-state 1H NMR spectroscopy. Analyses were performed at room temperature (24.9 ± 0.1 °C) on a 400 MHz (9.4 Tesla) Bruker BioSpin AVANCE III spectrometer fitted with a double-resonance broadband inverse (BBI) probe at the College of Sciences Major Instrumentation Cluster (COSMIC) facility of Old Dominion University (Norfolk, VA). Instrument control and data processing were performed using the TopSpin software. Analyses were performed without pre-concentration (e.g., via solid-phase extraction) or filtering on aliquots of samples taken at different time points. Samples were prepared by mixing a 516-µL aliquot of the sample with 60 µL deuterated water (Acros Organics, 99.9% D, CAN RN 7789-20-0) to produce a 90:10 H2O:D2O solution necessary for obtaining a deuterium lock. Additionally, sodium 2,2,3,3-tetradeutero-3-trimethylsilylpropanoate was added (24 µL of 25 µM solution; Acros Organics, 98% D) to serve as an internal standard. Once all aliquots were added to an NMR tube, they were mixed using a vortex mixer. NMR tubes were pre-cleaned by soaking in aqua regia for 2+ weeks. Prior to use, each NMR tube is rinsed with ~250 mL of ultrapure water and dried at 60 °C to ensure no contamination.
One-dimensional (1D) quantitative 1H spectra were acquired using the PEW5shapepr pulse program, which utilizes Perfect Echo - WATERGATE and shaped presaturation techniques for water suppression (Adams et al., 2013, Whitty et al., 2019). The employment of this pulse sequence results in quantitative spectra, with the water resonance at 4.7 ppm being suppressed. The relaxation delay (D1) employed for all quantitative analyses was 13.5 s, which was determined after an inversion-recovery experiment. For each individual sample the 90° excitation pulse width (P1) and transmitter offset (O1) were optimized to ensure quantitativeness of the signals. The obtained free-induction decay of 4096 summed transients was zero-filled to a 16k-sized dataset and apodized using a 10-Hz Lorentzian window function.
Additional Data
Additional spectroscopic and mass spectrometric data is available from the authors upon request.
Data were processed in Microsoft Excel.
NMR spectra were processed using the TopSpin software. First, spectra were calibrated, phased, and baseline-corrected. Then, spectra were integrated in the following regions: CH3 (0.6 – 0.91 ppm), CRAM (0.91 – 3.15 ppm), HC-O-R (3.15 – 4.4 ppm), olefinic (5 – 6.5 ppm), aromatic (6.5 – 8.3 ppm), and CHO (8.3 – 10 ppm). Formate (~8.3 ppm), methanol (3.34 ppm), and acetate (~1.9 ppm) were also independently integrated following manual inspection of each spectrum. They were subtracted from the region they resonate at: for example, acetate (resonating at ~1.9 ppm) is removed from the CRAM region (0.91-3.15 ppm). The CRAM region range has been previously determined by McKee et al. 2024. All integrals were also corrected for minor background signals using blank correction obtained from the analysis of pure vanillin in ultrapure water.
To be able to use 1H NMR data for dissolved organic matter analysis (which is done via DOC, i.e., on a C-basis), the integrals (which are on H-basis as they originate from 1H spectra) were converted into C-basis integrals by multiplication with H/C molar ratios as following: 3 for CH3, 1 for CRAM (McKee et al. 2024), 1.1 for HC-O-R (Decesari et al., 2007), 1 for olefinic, 0.4 for aromatic (Decesari et al. 2007), and 1 for CHO.
This section documents curation actions performed prior to publication review with the submitter, and additional information relevant to understanding and reusing this dataset. It distinguishes changes made to the submitted (meta)data from unresolved issues and/or enhancements that improve future reuse and interoperability.
CURATION ACTIONS PERFORMED ON DATA
- Loaded Data for BCO-DMO repository.xlsx (Sheet1, header row 1), using filename as resource name; set missing value sentinels to "", "nd", "ND", "N.D."
- Renamed columns: "Laboratory time, hours" to laboratory_time, "Measured [DOC], ppm-C" to measured_DOC, "Measured [DOC] Standard Deviation" to measured_DOC_std_dev, "d13C Standard Deviation" to d13C_std_dev, "pH Standard Deviation" to pH_std_dev, "Measured ConAC (ppm-C)" to measured_ConAC, "Measured ConAC Standard Deviation" to measured_ConAC_std_dev, "Measured CRAM (ppm-C)" to measured_CRAM, "Measured CRAM Standard Deviation" to measured_CRAM_std_dev (d13C and pH kept unchanged since names already matched targets)
- Output file as 1009323_v1_doc_degradation_incubation.csv
CURATION ACTIONS PERFORMED ON METADATA
- BCO-DMO's standard metadata entry and text formatting steps were performed. See: https://www.bco-dmo.org/how-to/standard-curation-edits
- Included information from instrument descriptions in the methods section
- Expanded parameter definitions for clarity
ISSUES POTENTIALLY IMPACTING REUSE
- Dataset values seem to be derived values, based on the observations. The complete data is not referenced or provided as part of this submission.
- Metadata does not state whether a dilution correction was applied to reported concentrations to account for the ultrapure water added back after each 30-minute aeration/subsampling step to maintain the 350 mL total volume, nor how such a correction would be calculated; metadata does not clarify whether the reported parameter values represent raw measured concentrations or values adjusted for this dilution effect.
- Metadata does not specify how many independent irradiation experiments (replicates) were conducted.
| Parameter | Description | Units |
| laboratory_time | Time of irradiation; Cumulative duration of sample exposure recorded in 24-hour irradiation cycle increments | hours |
| measured_DOC | Measured Dissolved Organic Carbon | ppm-C |
| measured_DOC_std_dev | Standard Deviation of the Measured [DOC] | ppm-C |
| d13C | Stable carbon isotopic signature | ‰ |
| d13C_std_dev | Standard Deviation of the d13C | ‰ |
| pH | pH | unitless |
| pH_std_dev | Standard Deviation of the pH | unitless |
| measured_ConAC | Condensed aromatic carbon (ConAC) concentration | ppm-C |
| measured_ConAC_std_dev | Standard deviation of replicate ConAC measurements | ppm-C |
| measured_CRAM | Carboxyl-rich alicyclic molecule (CRAM) carbon concentration | ppm-C |
| measured_CRAM_std_dev | Standard deviation of replicate CRAM measurements | ppm-C |
| Dataset-specific Instrument Name | Thermo Orion Star Series benchtop conductivity meter |
| Generic Instrument Name | Benchtop pH Meter |
| Dataset-specific Description | pH measurements were performed using a Thermo Orion Star Series benchtop conductivity meter on unirradiated and irradiated vanillin solutions. The pH meter was calibrated daily with pH 4.01 buffer solution (YSI 3821), pH 7.00 buffer solution (YSI 3822), and pH 10.00 buffer solution (YSI 3823). |
| Generic Instrument Description | An instrument consisting of an electronic voltmeter and pH-responsive electrode that gives a direct conversion of voltage differences to differences of pH at the measurement temperature. (McGraw-Hill Dictionary of Scientific and Technical Terms)
This instrument does not map to the NERC instrument vocabulary term for 'pH Sensor' which measures values in the water column. Benchtop models are typically employed for stationary lab applications. |
| Dataset-specific Instrument Name | oven |
| Generic Instrument Name | Drying Oven |
| Dataset-specific Description | Ampoules were flame-sealing and then samples were digested in an oven at 160°C for 6 hours. |
| Generic Instrument Description | a heated chamber for drying |
| Dataset-specific Instrument Name | Agilent 1100 high-performance liquid chromatography system |
| Generic Instrument Name | High-Performance Liquid Chromatograph |
| Dataset-specific Description | Benzenepentacarboxylic acid (B5CA, C₁₁H₆O₁₀) and benzenehexacarboxylic acid (B6CA, C₁₂H₆O₁₂) were quantified using an Agilent 1100 high-performance liquid chromatography system (Wagner et al. 2017). |
| Generic Instrument Description | A High-performance liquid chromatograph (HPLC) is a type of liquid chromatography used to separate compounds that are dissolved in solution. HPLC instruments consist of a reservoir of the mobile phase, a pump, an injector, a separation column, and a detector. Compounds are separated by high pressure pumping of the sample mixture onto a column packed with microspheres coated with the stationary phase. The different components in the mixture pass through the column at different rates due to differences in their partitioning behavior between the mobile liquid phase and the stationary phase. |
| Dataset-specific Instrument Name | flatbed SUNTEST CPS+ solar simulator |
| Generic Instrument Name | irradiation system |
| Dataset-specific Description | Up to three 500 mL quartz flasks were placed in a flatbed SUNTEST CPS+ solar simulator equipped with a daylight UV glass filter (ATLAS Cat. No. 56052371, cutoff at ~290 nm) for simulating solar radiation outdoors. |
| Generic Instrument Description | A system of instruments/devices that provide irradiation of materials. Irradiation is an energy transfer process during which a material entity receives energy through radiation. |
| Dataset-specific Instrument Name | spooling-wire microcombustion (SWiM) device interfaced with an isotope-ratio mass spectrometer (IRMS) |
| Generic Instrument Name | Isotope-ratio Mass Spectrometer |
| Dataset-specific Description | Samples were freeze-dried and resuspended in ultrapure water to yield concentrated solutions necessary for analysis on a spooling-wire microcombustion (SWiM) device (Sessions et al., 2005) interfaced with an isotope-ratio mass spectrometer (IRMS) to determine the ratio of 13C to 12C atoms expressed in a delta notation (δ13C) and referenced to Vienna Pee Dee Belemnite (Camin et al. 2025). |
| Generic Instrument Description | The Isotope-ratio Mass Spectrometer is a particular type of mass spectrometer used to measure the relative abundance of isotopes in a given sample (e.g. VG Prism II Isotope Ratio Mass-Spectrometer). |
| Dataset-specific Instrument Name | Bruker BioSpin AVANCE III spectrometer |
| Generic Instrument Name | Nuclear Magnetic Resonance Spectrometers |
| Dataset-specific Description | Analyses were performed at room temperature (24.9 ± 0.1 °C) on a 400 MHz (9.4 Tesla) Bruker BioSpin AVANCE III spectrometer fitted with a double-resonance broadband inverse (BBI) probe at the College of Sciences Major Instrumentation Cluster (COSMIC) facility of Old Dominion University (Norfolk, VA). |
| Generic Instrument Description | Instruments that identify and quantify magnetically active chemical entities by subjecting a sample to orthogonal magnetic and electrical fields. |
| Dataset-specific Instrument Name | Shimadzu TOC-VCPH |
| Generic Instrument Name | Shimadzu Total Organic Carbon Analyzer TOC-VCPH |
| Dataset-specific Description | Dissolved organic matter was quantified as dissolved organic carbon (DOC) equivalents (in mg-C/L) on a Shimadzu TOC-VCPH instrument following standard operating procedures. |
| Generic Instrument Description | The Shimadzu Total Organic Carbon Analyzer TOC-VCPH is a PC-controlled, total organic carbon analyzer (high-sensitivity model), designed to measure total carbon (TC), inorganic carbon (IC), total organic carbon (TOC), and non-purgeable organic carbon (NPOC); an optional accessory enables the measurement of particulate organic carbon (POC) and total nitrogen (TN) as well. The instrument uses the 680 degrees Celsius combustion catalytic oxidation method to analyze aqueous samples, and optionally solid and gas samples. |
| Dataset-specific Instrument Name | vortex mixer |
| Generic Instrument Name | vortex mixer |
| Dataset-specific Description | Additionally, sodium 2,2,3,3-tetradeutero-3-trimethylsilylpropanoate was added (24 µL of 25 µM solution; Acros Organics, 98% D) to serve as an internal standard. Once all aliquots were added to an NMR tube, they were mixed using a vortex mixer. |
| Generic Instrument Description | A vortex mixer is an electrical rotator that blends or mixes substances or ingredients, in whirling or rotary motion, for homogenizing samples. |
NSF Award Abstract:
Organic carbon in the ocean is made-up of materials delivered by riverine runoff from land and marine sources. However, even though a large amount of land-derived organic carbon enters the ocean from rivers, most carbon in the ocean appears to be from marine sources. This has led scientists to conclude that land-derived carbon is not transported far into the ocean. This EAGER project aims to test this assumption. The team of scientists will examine whether chemical reactions alter the composition of land-derived organic carbon in a way that makes it look like marine organic carbon. If this proves true, the results could explain why land-derived organic carbon is difficult to identify in the ocean and could lead to a reconsideration of present carbon budgets and models. The scientists will perform experiments using land-derived carbon collected from major river systems throughout the world. Samples will be introduced to reactive oxygen species (mainly hydroxyl radicals) and iron in the dark under conditions that occur in nature. Reaction rates and changes in the composition of the organic matter will be monitored during and following the experiments. This EAGER project provides research training and valuable professional development experience for an early career researcher who has not received prior support from NSF. Undergraduate students enrolled in STEM and REU programs at the lead institutions will participate in the research.
This EAGER project examines the hypothesis that hydroxyl radicals generated during dark Fenton reactions react with terrigenous organic matter to produce organic matter that is compositionally and isotopically similar to marine organic matter. The PIs will test this hypothesis using environmentally relevant concentrations of hydroxyl radical and terrestrial organic matter samples collected from several large-scale terrestrial riverine systems. The PIs will use multiple methods to characterize bulk organic matter (infrared/nuclear magnetic resonance (NMR) spectroscopy), its molecular composition (electrospray ionization Fourier Transform ion cyclotron resonance mass spectrometry (ESI FT-ICR MS), and stable isotope values of carbon and nitrogen (δ13C, δ15N) of dissolved and particulate organic matter pools before, during and following the experiments. This study explores an untested, but potentially transformative hypothesis that could alter existing paradigms about the fate of terrestrial organic matter in the ocean. Results from this study could revise understanding of the contributions of terrigenous organic matter to the ocean carbon cycle. The project would provide research and professional development opportunities for an early career investigator who has not received prior NSF support (co-PI Goranov). Undergraduates enrolled in REU and STEM training programs at the PIs’ home institutions would participate in the research.
This award reflects NSF's statutory mission and has been deemed worthy of support through evaluation using the Foundation's intellectual merit and broader impacts review criteria.
| Funding Source | Award |
|---|---|
| NSF Division of Ocean Sciences (NSF OCE) |