<?xml version="1.0" encoding="utf-8" ?><gmi:MI_Metadata
  xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
  xmlns:gco="http://www.isotc211.org/2005/gco"
  xmlns:gfc="http://www.isotc211.org/2005/gfc"
  xmlns:gmd="http://www.isotc211.org/2005/gmd"
  xmlns:xlink="http://www.w3.org/1999/xlink"
  xmlns:srv="http://www.isotc211.org/2005/srv"
  xmlns:gml="http://www.opengis.net/gml/3.2"
  xmlns:gsr="http://www.isotc211.org/2005/gsr"
  xmlns:gss="http://www.isotc211.org/2005/gss"
  xmlns:gts="http://www.isotc211.org/2005/gts"
  xmlns:gmi="http://www.isotc211.org/2005/gmi"
  xmlns:gmx="http://www.isotc211.org/2005/gmx"
  xsi:schemaLocation="http://www.isotc211.org/2005/gmi https://data.noaa.gov/resources/iso19139/schema.xsd">
  <gmd:fileIdentifier>
    <gco:CharacterString>http://lod.bco-dmo.org/id/dataset/1009323</gco:CharacterString>
  </gmd:fileIdentifier>
  <gmd:language>
    <gco:CharacterString>eng; USA</gco:CharacterString>
  </gmd:language>
  <gmd:characterSet>
    <gmd:MD_CharacterSetCode codeList="http://www.isotc211.org/2005/resources/Codelist/gmxCodelists.xml#MD_CharacterSetCode" codeListValue="utf8">utf8</gmd:MD_CharacterSetCode>
  </gmd:characterSet>
  <gmd:hierarchyLevel>
    <gmd:MD_ScopeCode codeList="http://www.isotc211.org/2005/resources/Codelist/gmxCodelists.xml#MD_ScopeCode" codeListValue="dataset" codeSpace="005">dataset</gmd:MD_ScopeCode>
  </gmd:hierarchyLevel>
  <gmd:hierarchyLevelName>
    <gco:CharacterString>Highest level of data collection, from a common set of sensors or instrumentation, usually within the same research project</gco:CharacterString>
  </gmd:hierarchyLevelName>
  <gmd:contact>
    <gmd:CI_ResponsibleParty>
  <gmd:organisationName>
    <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/affiliation/191.rdf" xlink:actuate="onRequest">Biological and Chemical Oceanography Data Management Office (BCO-DMO)</gmx:Anchor>
  </gmd:organisationName>
  <gmd:contactInfo>
    <gmd:CI_Contact>
		  <gmd:phone>
		    <gmd:CI_Telephone>
				  <gmd:voice>
				    <gco:CharacterString>Unavailable</gco:CharacterString>
				  </gmd:voice>
				  <gmd:facsimile>
				    <gco:CharacterString>508-289-2009</gco:CharacterString>
				  </gmd:facsimile>
				</gmd:CI_Telephone>
		  </gmd:phone>
		  <gmd:address>
		    <gmd:CI_Address>
				  <gmd:deliveryPoint>
				    <gco:CharacterString>WHOI MS#36</gco:CharacterString>
				  </gmd:deliveryPoint>
				  <gmd:city>
				    <gco:CharacterString>Woods Hole</gco:CharacterString>
				  </gmd:city>
				  <gmd:administrativeArea>
				    <gco:CharacterString>MA</gco:CharacterString>
				  </gmd:administrativeArea>
				  <gmd:postalCode>
				    <gco:CharacterString>02543</gco:CharacterString>
				  </gmd:postalCode>
				  <gmd:country>
				    <gco:CharacterString>USA</gco:CharacterString>
				  </gmd:country>
				  <gmd:electronicMailAddress>
				    <gco:CharacterString>info@bco-dmo.org</gco:CharacterString>
				  </gmd:electronicMailAddress>
		    </gmd:CI_Address>
		  </gmd:address>
      <gmd:onlineResource>
          <gmd:CI_OnlineResource>
            <gmd:linkage>
              <gmd:URL>http://www.bco-dmo.org</gmd:URL>
            </gmd:linkage>
          </gmd:CI_OnlineResource>
        </gmd:onlineResource>
		  <gmd:hoursOfService>
        <gco:CharacterString>Monday - Friday 8:00am - 5:00pm</gco:CharacterString>
      </gmd:hoursOfService>
		  <gmd:contactInstructions>
		    <gco:CharacterString>For questions regarding this resource, please contact BCO-DMO via the email address provided.</gco:CharacterString>
		  </gmd:contactInstructions>
		</gmd:CI_Contact>
  </gmd:contactInfo>
  <gmd:role>
    <gmd:CI_RoleCode codeList="http://www.isotc211.org/2005/resources/Codelist/gmxCodelists.xml#CI_RoleCode" codeListValue="pointOfContact"  codeSpace="007">pointOfContact</gmd:CI_RoleCode>
  </gmd:role>
</gmd:CI_ResponsibleParty>
  </gmd:contact>
  <gmd:dateStamp>
    <gco:Date>2026-10-08</gco:Date>
  </gmd:dateStamp>
  <gmd:metadataStandardName>
    <gco:CharacterString>ISO 19115-2 Geographic Information - Metadata - Part 2: Extensions for Imagery and Gridded Data</gco:CharacterString>
  </gmd:metadataStandardName>
  <gmd:metadataStandardVersion>
    <gco:CharacterString>ISO 19115-2:2009(E)</gco:CharacterString>
  </gmd:metadataStandardVersion>
  <gmd:referenceSystemInfo xlink:href="https://data.noaa.gov/docucomp/895cc120-95ed-11e0-aa80-0800200c9a66" xlink:title="WGS 84 / World Mercator"/>
  <gmd:identificationInfo>
    <gmd:MD_DataIdentification>
      <gmd:citation>
        <gmd:CI_Citation>
          <gmd:title>
            <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/dataset/1009323.rdf" xlink:actuate="onRequest">Changes in dissolved organic carbon, stable carbon isotopes, pH, condensed aromatic carbon, and carboxyl-rich alicyclic molecules during laboratory photo-irradiation of vanillin</gmx:Anchor>
          </gmd:title>
          <gmd:date>
            <gmd:CI_Date>
              <gmd:date>
                <gco:Date>2026-10-08</gco:Date>
              </gmd:date>
              <gmd:dateType>
                <gmd:CI_DateTypeCode codeList="http://www.isotc211.org/2005/resources/Codelist/gmxCodelists.xml#CI_DateTypeCode" codeListValue="publication" codeSpace="ISOTC211/19115">publication</gmd:CI_DateTypeCode>
              </gmd:dateType>
            </gmd:CI_Date>
          </gmd:date>
          <gmd:date>
            <gmd:CI_Date>
              <gmd:date>
                <gco:Date>2026-10-08</gco:Date>
              </gmd:date>
              <gmd:dateType>
                <gmd:CI_DateTypeCode codeList="http://www.isotc211.org/2005/resources/Codelist/gmxCodelists.xml#CI_DateTypeCode" codeListValue="revision" codeSpace="ISOTC211/19115">revision</gmd:CI_DateTypeCode>
              </gmd:dateType>
            </gmd:CI_Date>
          </gmd:date>
          <gmd:edition>
            <gco:CharacterString/>
          </gmd:edition>
          <gmd:identifier>
            <gmd:MD_Identifier>
              <gmd:authority>
                <gmd:CI_Citation>
                  <gmd:title>
                    <gco:CharacterString>BCO-DMO Linked Data URI</gco:CharacterString>
                  </gmd:title>
                  <gmd:date>
                    <gmd:CI_Date>
                      <gmd:date>
                        <gco:Date>2026-10-08</gco:Date>
                      </gmd:date>
                      <gmd:dateType>
                        <gmd:CI_DateTypeCode codeList="http://www.isotc211.org/2005/resources/Codelist/gmxCodelists.xml#CI_DateTypeCode" codeListValue="creation">creation</gmd:CI_DateTypeCode>
                      </gmd:dateType>
                    </gmd:CI_Date>
                  </gmd:date>
                </gmd:CI_Citation>
              </gmd:authority>
              <gmd:code>
                <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/dataset/1009323" xlink:actuate="onRequest">http://lod.bco-dmo.org/id/dataset/1009323</gmx:Anchor>
              </gmd:code>
            </gmd:MD_Identifier>
          </gmd:identifier>
          <gmd:citedResponsibleParty>
           <gmd:CI_ResponsibleParty>
              <gmd:individualName>
                <gmx:Anchor xlink:href="http://orcid.org/0000-0002-1606-1305" xlink:title="ORCID" xlink:actuate="onRequest">Patrick G. Hatcher</gmx:Anchor>
              </gmd:individualName>
              <gmd:organisationName>
                <gmx:Anchor xlink:href="https://ror.org/04zjtrb98" xlink:title="ROR ID" xlink:actuate="onRequest">Old Dominion University</gmx:Anchor>
              </gmd:organisationName>
              <gmd:positionName>
               <gco:CharacterString></gco:CharacterString>
              </gmd:positionName>
              <gmd:role>
                <gmd:CI_RoleCode codeList="http://www.isotc211.org/2005/resources/Codelist/gmxCodelists.xml#CI_RoleCode" codeListValue="principalInvestigator" codeSpace="008">principalInvestigator</gmd:CI_RoleCode>
              </gmd:role>
            </gmd:CI_ResponsibleParty>
          </gmd:citedResponsibleParty>
          <gmd:citedResponsibleParty>
           <gmd:CI_ResponsibleParty>
              <gmd:individualName>
                <gmx:Anchor xlink:href="http://orcid.org/0000-0002-5103-0838" xlink:title="ORCID" xlink:actuate="onRequest">Aleksandar I. Goranov</gmx:Anchor>
              </gmd:individualName>
              <gmd:organisationName>
                <gmx:Anchor xlink:href="https://ror.org/04zjtrb98" xlink:title="ROR ID" xlink:actuate="onRequest">Old Dominion University</gmx:Anchor>
              </gmd:organisationName>
              <gmd:positionName>
               <gco:CharacterString></gco:CharacterString>
              </gmd:positionName>
              <gmd:role>
                <gmd:CI_RoleCode codeList="http://www.isotc211.org/2005/resources/Codelist/gmxCodelists.xml#CI_RoleCode" codeListValue="principalInvestigator" codeSpace="008">principalInvestigator</gmd:CI_RoleCode>
              </gmd:role>
            </gmd:CI_ResponsibleParty>
          </gmd:citedResponsibleParty>
          <gmd:citedResponsibleParty>
           <gmd:CI_ResponsibleParty>
              <gmd:individualName>
                <gmx:Anchor xlink:href="http://orcid.org/0000-0003-2785-8405" xlink:title="ORCID" xlink:actuate="onRequest">Ann Pearson</gmx:Anchor>
              </gmd:individualName>
              <gmd:organisationName>
                <gmx:Anchor xlink:href="https://ror.org/03vek6s52" xlink:title="ROR ID" xlink:actuate="onRequest">Harvard University</gmx:Anchor>
              </gmd:organisationName>
              <gmd:positionName>
               <gco:CharacterString></gco:CharacterString>
              </gmd:positionName>
              <gmd:role>
                <gmd:CI_RoleCode codeList="http://www.isotc211.org/2005/resources/Codelist/gmxCodelists.xml#CI_RoleCode" codeListValue="principalInvestigator" codeSpace="008">principalInvestigator</gmd:CI_RoleCode>
              </gmd:role>
            </gmd:CI_ResponsibleParty>
          </gmd:citedResponsibleParty>
          <gmd:citedResponsibleParty>
           <gmd:CI_ResponsibleParty>
              <gmd:individualName>
                <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/person/1009330.rdf" xlink:actuate="onRequest">Hongmei Chen</gmx:Anchor>
              </gmd:individualName>
              <gmd:organisationName>
                <gmx:Anchor xlink:href="https://ror.org/04zjtrb98" xlink:title="ROR ID" xlink:actuate="onRequest">Old Dominion University</gmx:Anchor>
              </gmd:organisationName>
              <gmd:positionName>
               <gco:CharacterString></gco:CharacterString>
              </gmd:positionName>
              <gmd:role>
                <gmd:CI_RoleCode codeList="http://www.isotc211.org/2005/resources/Codelist/gmxCodelists.xml#CI_RoleCode" codeListValue="principalInvestigator" codeSpace="008">principalInvestigator</gmd:CI_RoleCode>
              </gmd:role>
            </gmd:CI_ResponsibleParty>
          </gmd:citedResponsibleParty>
          <gmd:citedResponsibleParty>
            <gmd:CI_ResponsibleParty>
  <gmd:organisationName>
    <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/affiliation/191.rdf" xlink:actuate="onRequest">Biological and Chemical Oceanography Data Management Office (BCO-DMO)</gmx:Anchor>
  </gmd:organisationName>
  <gmd:contactInfo>
    <gmd:CI_Contact>
		  <gmd:phone>
		    <gmd:CI_Telephone>
				  <gmd:voice>
				    <gco:CharacterString>Unavailable</gco:CharacterString>
				  </gmd:voice>
				  <gmd:facsimile>
				    <gco:CharacterString>508-289-2009</gco:CharacterString>
				  </gmd:facsimile>
				</gmd:CI_Telephone>
		  </gmd:phone>
		  <gmd:address>
		    <gmd:CI_Address>
				  <gmd:deliveryPoint>
				    <gco:CharacterString>WHOI MS#36</gco:CharacterString>
				  </gmd:deliveryPoint>
				  <gmd:city>
				    <gco:CharacterString>Woods Hole</gco:CharacterString>
				  </gmd:city>
				  <gmd:administrativeArea>
				    <gco:CharacterString>MA</gco:CharacterString>
				  </gmd:administrativeArea>
				  <gmd:postalCode>
				    <gco:CharacterString>02543</gco:CharacterString>
				  </gmd:postalCode>
				  <gmd:country>
				    <gco:CharacterString>USA</gco:CharacterString>
				  </gmd:country>
				  <gmd:electronicMailAddress>
				    <gco:CharacterString>info@bco-dmo.org</gco:CharacterString>
				  </gmd:electronicMailAddress>
		    </gmd:CI_Address>
		  </gmd:address>
      <gmd:onlineResource>
          <gmd:CI_OnlineResource>
            <gmd:linkage>
              <gmd:URL>http://www.bco-dmo.org</gmd:URL>
            </gmd:linkage>
          </gmd:CI_OnlineResource>
        </gmd:onlineResource>
		  <gmd:hoursOfService>
        <gco:CharacterString>Monday - Friday 8:00am - 5:00pm</gco:CharacterString>
      </gmd:hoursOfService>
		  <gmd:contactInstructions>
		    <gco:CharacterString>For questions regarding this resource, please contact BCO-DMO via the email address provided.</gco:CharacterString>
		  </gmd:contactInstructions>
		</gmd:CI_Contact>
  </gmd:contactInfo>
  <gmd:role>
    <gmd:CI_RoleCode codeList="http://www.isotc211.org/2005/resources/Codelist/gmxCodelists.xml#CI_RoleCode" codeListValue="publisher" >publisher</gmd:CI_RoleCode>
  </gmd:role>
</gmd:CI_ResponsibleParty>
          </gmd:citedResponsibleParty>
          <gmd:otherCitationDetails>
            <gco:CharacterString>Cite this dataset as: Goranov, A. I., Aguilar-Martinez, S. Z., Chen, H., Pearson, A., Hatcher, P. G. (2026) Changes in dissolved organic carbon, stable carbon isotopes, pH, condensed aromatic carbon, and carboxyl-rich alicyclic molecules during laboratory photo-irradiation of vanillin. Biological and Chemical Oceanography Data Management Office (BCO-DMO). (Version 1) Version Date 2026-10-08 [if applicable, indicate subset used]. http://lod.bco-dmo.org/id/dataset/1009323 [access date]</gco:CharacterString>
          </gmd:otherCitationDetails>
          </gmd:CI_Citation>
      </gmd:citation>
      <gmd:abstract>
        <gco:CharacterString>Vanillin photochemical experiment Dataset Description:  Methods and Sampling: &amp;lt;p&amp;gt;Vanillin (Acros, 99%), a lignin monophenol, was chosen as a representative monomeric unit of lignin, a major component of tDOM (Opsahl and Benner, 1998). A solution of 20 mg-C of vanillin in 1 L ultrapure MilliQ water was prepared to serve as a stock solution in photochemical experiments. This concentration was chosen because it is representative to carbon contents in upstream terrestrial aquatic environments such as rivers and lakes (Gonsior et al., 2009).&amp;lt;/p&amp;gt;

&amp;lt;p&amp;gt;&amp;lt;strong&amp;gt;Photo-irradiation.&amp;amp;nbsp;&amp;lt;/strong&amp;gt;Approximately 350 mL of vanillin stock solution was aliquoted into a pre-combusted 500 mL quartz round-bottom flask capped with a pre-combusted glass cap. An aliquot of the stock solution was immediately wrapped with aluminum foil and stored at room temperature as a dark control. Another aliquot of the stock solution was frozen to evaluate the stability of the dark control at room temperature. Up to three 500 mL quartz flasks were placed in a flatbed SUNTEST CPS+ solar simulator equipped with a daylight UV glass filter (ATLAS Cat. No. 56052371, cutoff at ~290 nm) for simulating solar radiation outdoors. Irradiation was performed under controlled chamber air temperature of 35 °C&amp;amp;nbsp;in 24-hour cycles using power of 250 W/m&amp;lt;sup&amp;gt;2&amp;lt;/sup&amp;gt; yielding ~21,600 kJ/m&amp;lt;sup&amp;gt;2&amp;lt;/sup&amp;gt; per 24 hours. Flasks were irradiated for 24 hours and then opened for 30 minutes during which they were aerated and gently stirred. During this aeration step, a 20-, 40-, or 50-mL subsample was taken out for analyses. To keep the same total volume throughout the irradiation (350 mL), the same amount of ultrapure water was added back. Multiple irradiation experiments were performed to yield sufficient sample volumes for the different analytical methods employed for the characterization of the photo-products.&amp;amp;nbsp;&amp;lt;/p&amp;gt;

&amp;lt;p&amp;gt;&amp;lt;strong&amp;gt;Dissolved organic carbon.&amp;amp;nbsp;&amp;lt;/strong&amp;gt;Dissolved organic matter was quantified as dissolved organic carbon (DOC) equivalents (in mg-C/L) on a Shimadzu TOC-VCPH instrument following standard operating procedures. Briefly, samples were acidified and sparged with air for 3 minutes to remove any inorganic carbon species (dissolved CO, CO2, HCO3-, CO32-) or other dissolved volatile gases (e.g., CH4). Then, samples were injected in a high temperature combustion reactor (720 ˚C) to oxidize the DOM to CO2. Detection of CO2 is achieved using a non-dispersive infrared detector. DOC concentrations were quantified using standard calibration curves made with potassium hydrogen phthalate (Nacalai Tesque, JIS special grade).&amp;lt;/p&amp;gt;

&amp;lt;p&amp;gt;&amp;lt;strong&amp;gt;Stable carbon isotopic composition (δ13C&amp;lt;/strong&amp;gt;). Photo-irradiated solutions of vanillin were aliquoted to Falcon® tubes that were pre-aged in 2 % (w/w) NaOH for one month to remove any leachable carbon. Samples were freeze-dried and resuspended in ultrapure water to yield concentrated solutions necessary for analysis on a spooling-wire microcombustion (SWiM) device (Sessions et al. 2005) interfaced with an isotope-ratio mass spectrometer (IRMS) to determine the ratio of 13C to 12C atoms expressed in a delta notation (δ13C) and referenced to Vienna Pee Dee Belemnite (Camin et al. 2025).&amp;lt;/p&amp;gt;

&amp;lt;p&amp;gt;The SWiM system used has been employed previously to measure δ¹³C values of aqueous samples (Mohr et al. 2014). The SWiM interface is connected to a ThermoFinnigan DeltaPlus Advantage IRMS via an open split. Reference CO₂ is controlled using a Conflo III, and data are collected and analyzed using Isodat v3.0.&amp;amp;nbsp; Each analytical run begins with three pulses of standard CO₂ reference gas and ends with two pulses of standard CO₂ reference gas. Samples were injected in 1 μL aliquots, separated by 30 sec; 3 to 5 injections are made of each sample.&amp;amp;nbsp; All data are corrected assuming linear drift of the m/z 45/44 ratio over the duration of the run. Each run includes samples (unknowns) and standard dilution series of two laboratory reference materials (dextrose, -11.2‰, and nor-leucine, -27.7‰). Empty tube blanks containing ultrapure water are also measured. Directly measured blank δ¹³C values were smaller than values inferred from the dilution series, determined by the intersection of δ¹³C versus Area-1 for the two dilution series, which intersect at Area-1 and δ¹³C of the blank. All samples were subsequently blank-corrected using the intersection of these two lines.&amp;lt;/p&amp;gt;

&amp;lt;p&amp;gt;&amp;lt;strong&amp;gt;pH&amp;lt;/strong&amp;gt;. pH measurements were performed using a Thermo Orion Star Series benchtop conductivity meter on unirradiated and irradiated vanillin solutions. The pH meter was calibrated daily with pH 4.01 buffer solution (YSI 3821), pH 7.00 buffer solution (YSI 3822), and pH 10.00 buffer solution (YSI 3823).&amp;lt;/p&amp;gt;

&amp;lt;p&amp;gt;&amp;lt;strong&amp;gt;Condensed aromatic carbon (ConAC).&amp;lt;/strong&amp;gt;&amp;amp;nbsp;Exactly 40 mL of vanillin control and photochemically processed samples were freeze-dried. The obtained residue was redissolved in 2 mL of 1:1 methanol:water and transferred to 2-mL glass ampules. The solvent was evaporated at 60 °C and the residue was mixed with 0.5 mL concentrated nitric acid (65 %). Ampoules were flame-sealing and then samples were digested in an oven at 160°C for 6 hours. After this thermal digestion, the nitric acid was evaporated at 70°C in a sand bath under a stream of ultrapure nitrogen. The residue was redissolved in 0.5 mL of 0.6 mol L⁻¹ H₃PO₄ and filtered through a 0.2 µm syringe filter (Thermo Scientific™ Titan3™ PTFE). Benzenepentacarboxylic acid (B5CA, C₁₁H₆O₁₀) and benzenehexacarboxylic acid (B6CA, C₁₂H₆O₁₂) were quantified using an Agilent 1100 high-performance liquid chromatography system (Wagner et al. 2017). Their concentrations were then converted to carbon concentrations (i.e., B6CAC and B5CAC) and used to estimate the ConAC content of the original sample prior to digestion by multiplying by a scaling factor of 7.04 (Bostick et al., 2018) followed by normalization to organic carbon content. The molar ratio of B6CA to B5CA was also calculated to serve as an indicator of the degree of condensation of ConAC.&amp;amp;nbsp;&amp;lt;/p&amp;gt;

&amp;lt;p&amp;gt;&amp;lt;strong&amp;gt;Carboxyl-rich alicyclic molecules (CRAM).&amp;amp;nbsp;&amp;lt;/strong&amp;gt;Carboxyl-rich alicyclic molecules (CRAM) were quantified using liquid-state 1H NMR spectroscopy. Analyses were performed at room temperature (24.9 ± 0.1 °C) on a 400 MHz (9.4 Tesla) Bruker BioSpin AVANCE III spectrometer fitted with a double-resonance broadband inverse (BBI) probe at the College of Sciences Major Instrumentation Cluster (COSMIC) facility of Old Dominion University (Norfolk, VA). Instrument control and data processing were performed using the TopSpin software. Analyses were performed without pre-concentration (e.g., via solid-phase extraction) or filtering on aliquots of samples taken at different time points. Samples were prepared by mixing a 516-µL aliquot of the sample with 60 µL deuterated water (Acros Organics, 99.9% D, CAN RN 7789-20-0) to produce a 90:10 H2O:D2O solution necessary for obtaining a deuterium lock. Additionally, sodium 2,2,3,3-tetradeutero-3-trimethylsilylpropanoate was added (24 µL of 25 µM solution; Acros Organics, 98% D) to serve as an internal standard. Once all aliquots were added to an NMR tube, they were mixed using a vortex mixer. NMR tubes were pre-cleaned by soaking in aqua regia for 2+ weeks. Prior to use, each NMR tube is rinsed with ~250 mL of ultrapure water and dried at 60 °C to ensure no contamination.&amp;lt;/p&amp;gt;

&amp;lt;p&amp;gt;One-dimensional (1D) quantitative 1H spectra were acquired using the PEW5shapepr pulse program, which utilizes Perfect Echo - WATERGATE and shaped presaturation techniques for water suppression (Adams et al., 2013, Whitty et al., 2019). The employment of this pulse sequence results in quantitative spectra, with the water resonance at 4.7 ppm being suppressed. The relaxation delay (D1) employed for all quantitative analyses was 13.5 s, which was determined after an inversion-recovery experiment. For each individual sample the 90° excitation pulse width (P1) and transmitter offset (O1) were optimized to ensure quantitativeness of the signals. The obtained free-induction decay of 4096 summed transients was zero-filled to a 16k-sized dataset and apodized using a 10-Hz Lorentzian window function.&amp;amp;nbsp;&amp;lt;/p&amp;gt;

&amp;lt;p&amp;gt;&amp;lt;strong&amp;gt;Additional Data&amp;lt;/strong&amp;gt;&amp;amp;nbsp;&amp;lt;/p&amp;gt;

&amp;lt;p&amp;gt;Additional spectroscopic and mass spectrometric data is available from the authors upon request.&amp;lt;/p&amp;gt;</gco:CharacterString>
      </gmd:abstract>
      <gmd:credit>
        <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/award/941589.rdf" xlink:title="OCE-2346285" xlink:actuate="onRequest">Funding provided by NSF Division of Ocean Sciences (NSF OCE) Award Number: OCE-2346285 Award URL: https://www.nsf.gov/awardsearch/show-award?AWD_ID=2346285</gmx:Anchor>
      </gmd:credit>
        <gmd:status>
        <gmd:MD_ProgressCode codeList="http://www.isotc211.org/2005/resources/Codelist/gmxCodelists.xml#MD_ProgressCode" codeListValue="onGoing">onGoing</gmd:MD_ProgressCode>
      </gmd:status>
      <gmd:pointOfContact>
        <gmd:CI_ResponsibleParty>
          <gmd:individualName>
            <gmx:Anchor xlink:href="http://orcid.org/0000-0002-1606-1305" xlink:actuate="onRequest">Patrick G. Hatcher</gmx:Anchor>
          </gmd:individualName>
          <gmd:organisationName>
            <gmx:Anchor xlink:href="https://ror.org/04zjtrb98" xlink:title="ROR ID" xlink:actuate="onRequest">Old Dominion University</gmx:Anchor>
          </gmd:organisationName>
          <gmd:contactInfo>
            <gmd:CI_Contact>
            <gmd:phone>
                <gmd:CI_Telephone>
                  <gmd:voice>
                    <gco:CharacterString>614-323-8799</gco:CharacterString>
                  </gmd:voice>
                </gmd:CI_Telephone>
              </gmd:phone>
            <gmd:address>
                <gmd:CI_Address>
                                  <gmd:deliveryPoint>
                    <gco:CharacterString>4402 Elkhorn Ave. Department of Chemistry and Biochemistry</gco:CharacterString>
                  </gmd:deliveryPoint>
                                  <gmd:city>
                    <gco:CharacterString>Norfolk</gco:CharacterString>
                  </gmd:city>                  <gmd:administrativeArea>
                    <gco:CharacterString>VA</gco:CharacterString>
                  </gmd:administrativeArea>                  <gmd:postalCode>
                    <gco:CharacterString>23529</gco:CharacterString>
                  </gmd:postalCode>                  <gmd:country>
                    <gco:CharacterString>USA</gco:CharacterString>
                  </gmd:country>                  <gmd:electronicMailAddress>
                    <gco:CharacterString>phatcher@odu.edu</gco:CharacterString>
                  </gmd:electronicMailAddress>
                </gmd:CI_Address>
              </gmd:address>
            </gmd:CI_Contact>
          </gmd:contactInfo>
          <gmd:role>
            <gmd:CI_RoleCode codeList="http://www.isotc211.org/2005/resources/Codelist/gmxCodelists.xml#CI_RoleCode" codeListValue="pointOfContact" codeSpace="007">pointOfContact</gmd:CI_RoleCode>
          </gmd:role>
        </gmd:CI_ResponsibleParty>
      </gmd:pointOfContact>
      <gmd:pointOfContact>
        <gmd:CI_ResponsibleParty>
          <gmd:individualName>
            <gmx:Anchor xlink:href="http://orcid.org/0000-0002-5103-0838" xlink:actuate="onRequest">Aleksandar I. Goranov</gmx:Anchor>
          </gmd:individualName>
          <gmd:organisationName>
            <gmx:Anchor xlink:href="https://ror.org/04zjtrb98" xlink:title="ROR ID" xlink:actuate="onRequest">Old Dominion University</gmx:Anchor>
          </gmd:organisationName>
          <gmd:contactInfo>
            <gmd:CI_Contact>
            <gmd:address>
                <gmd:CI_Address>
                                  <gmd:deliveryPoint>
                    <gco:CharacterString>3000A Chemistry Building 4501 Elkhorn Ave.</gco:CharacterString>
                  </gmd:deliveryPoint>
                                  <gmd:city>
                    <gco:CharacterString>Norfolk</gco:CharacterString>
                  </gmd:city>                  <gmd:administrativeArea>
                    <gco:CharacterString>VA</gco:CharacterString>
                  </gmd:administrativeArea>                  <gmd:postalCode>
                    <gco:CharacterString>23529</gco:CharacterString>
                  </gmd:postalCode>                  <gmd:country>
                    <gco:CharacterString>USA</gco:CharacterString>
                  </gmd:country>                  <gmd:electronicMailAddress>
                    <gco:CharacterString>aleksandar.i.goranov@gmail.com</gco:CharacterString>
                  </gmd:electronicMailAddress>
                </gmd:CI_Address>
              </gmd:address>
            </gmd:CI_Contact>
          </gmd:contactInfo>
          <gmd:role>
            <gmd:CI_RoleCode codeList="http://www.isotc211.org/2005/resources/Codelist/gmxCodelists.xml#CI_RoleCode" codeListValue="pointOfContact" codeSpace="007">pointOfContact</gmd:CI_RoleCode>
          </gmd:role>
        </gmd:CI_ResponsibleParty>
      </gmd:pointOfContact>
      <gmd:pointOfContact>
        <gmd:CI_ResponsibleParty>
          <gmd:individualName>
            <gmx:Anchor xlink:href="http://orcid.org/0000-0003-2785-8405" xlink:actuate="onRequest">Ann Pearson</gmx:Anchor>
          </gmd:individualName>
          <gmd:organisationName>
            <gmx:Anchor xlink:href="https://ror.org/03vek6s52" xlink:title="ROR ID" xlink:actuate="onRequest">Harvard University</gmx:Anchor>
          </gmd:organisationName>
          <gmd:contactInfo>
            <gmd:CI_Contact>
            <gmd:phone>
                <gmd:CI_Telephone>
                  <gmd:voice>
                    <gco:CharacterString>617-384-8392</gco:CharacterString>
                  </gmd:voice>
                </gmd:CI_Telephone>
              </gmd:phone>
            <gmd:address>
                <gmd:CI_Address>
                                  <gmd:deliveryPoint>
                    <gco:CharacterString>Hoffman Lab G13 20 Oxford St.</gco:CharacterString>
                  </gmd:deliveryPoint>
                                  <gmd:city>
                    <gco:CharacterString>Cambridge</gco:CharacterString>
                  </gmd:city>                  <gmd:administrativeArea>
                    <gco:CharacterString>MA</gco:CharacterString>
                  </gmd:administrativeArea>                  <gmd:postalCode>
                    <gco:CharacterString>02138</gco:CharacterString>
                  </gmd:postalCode>                  <gmd:country>
                    <gco:CharacterString>USA</gco:CharacterString>
                  </gmd:country>                  <gmd:electronicMailAddress>
                    <gco:CharacterString>pearson@eps.harvard.edu</gco:CharacterString>
                  </gmd:electronicMailAddress>
                </gmd:CI_Address>
              </gmd:address>
            </gmd:CI_Contact>
          </gmd:contactInfo>
          <gmd:role>
            <gmd:CI_RoleCode codeList="http://www.isotc211.org/2005/resources/Codelist/gmxCodelists.xml#CI_RoleCode" codeListValue="pointOfContact" codeSpace="007">pointOfContact</gmd:CI_RoleCode>
          </gmd:role>
        </gmd:CI_ResponsibleParty>
      </gmd:pointOfContact>
      <gmd:pointOfContact>
        <gmd:CI_ResponsibleParty>
          <gmd:individualName>
            <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/person/1009330.rdf" xlink:actuate="onRequest">Hongmei Chen</gmx:Anchor>
          </gmd:individualName>
          <gmd:organisationName>
            <gmx:Anchor xlink:href="https://ror.org/04zjtrb98" xlink:title="ROR ID" xlink:actuate="onRequest">Old Dominion University</gmx:Anchor>
          </gmd:organisationName>
          <gmd:contactInfo>
            <gmd:CI_Contact>
            <gmd:address>
                <gmd:CI_Address>
                                  <gmd:electronicMailAddress>
                    <gco:CharacterString>chenhm@xmu.edu.cn</gco:CharacterString>
                  </gmd:electronicMailAddress>
                </gmd:CI_Address>
              </gmd:address>
            </gmd:CI_Contact>
          </gmd:contactInfo>
          <gmd:role>
            <gmd:CI_RoleCode codeList="http://www.isotc211.org/2005/resources/Codelist/gmxCodelists.xml#CI_RoleCode" codeListValue="pointOfContact" codeSpace="007">pointOfContact</gmd:CI_RoleCode>
          </gmd:role>
        </gmd:CI_ResponsibleParty>
      </gmd:pointOfContact>
            <gmd:resourceMaintenance>
        <gmd:MD_MaintenanceInformation>
          <gmd:maintenanceAndUpdateFrequency>
            <gmd:MD_MaintenanceFrequencyCode codeList="http://www.isotc211.org/2005/resources/Codelist/gmxCodelists.xml#MD_MaintenanceFrequencyCode" codeListValue="asNeeded" codeSpace="009">asNeeded</gmd:MD_MaintenanceFrequencyCode>
          </gmd:maintenanceAndUpdateFrequency>
          <gmd:maintenanceNote>
            <gco:CharacterString>Dataset Version: 1</gco:CharacterString>
          </gmd:maintenanceNote>
          </gmd:MD_MaintenanceInformation>
      </gmd:resourceMaintenance>
      <gmd:resourceFormat>
        <gmd:MD_Format>
          <gmd:name>
             <gco:CharacterString>Unknown</gco:CharacterString>
          </gmd:name>
          <gmd:version gco:nilReason="unknown"/>
          </gmd:MD_Format>
      </gmd:resourceFormat>
            <gmd:descriptiveKeywords>
        <gmd:MD_Keywords>
                <gmd:keyword>
          <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/dataset-parameter/1009345.rdf" xlink:title="http://lod.bco-dmo.org/id/parameter/1838.rdf" xlink:actuate="onRequest">laboratory_time</gmx:Anchor>
        </gmd:keyword>
                <gmd:keyword>
          <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/dataset-parameter/1009346.rdf" xlink:title="http://lod.bco-dmo.org/id/parameter/1188.rdf" xlink:actuate="onRequest">measured_DOC</gmx:Anchor>
        </gmd:keyword>
                <gmd:keyword>
          <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/dataset-parameter/1009347.rdf" xlink:title="http://lod.bco-dmo.org/id/parameter/1974.rdf" xlink:actuate="onRequest">measured_DOC_std_dev</gmx:Anchor>
        </gmd:keyword>
                <gmd:keyword>
          <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/dataset-parameter/1009348.rdf" xlink:title="http://lod.bco-dmo.org/id/parameter/671305.rdf" xlink:actuate="onRequest">d13C</gmx:Anchor>
        </gmd:keyword>
                <gmd:keyword>
          <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/dataset-parameter/1009349.rdf" xlink:title="http://lod.bco-dmo.org/id/parameter/1974.rdf" xlink:actuate="onRequest">d13C_std_dev</gmx:Anchor>
        </gmd:keyword>
                <gmd:keyword>
          <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/dataset-parameter/1009350.rdf" xlink:title="http://lod.bco-dmo.org/id/parameter/1892.rdf" xlink:actuate="onRequest">pH</gmx:Anchor>
        </gmd:keyword>
                <gmd:keyword>
          <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/dataset-parameter/1009351.rdf" xlink:title="http://lod.bco-dmo.org/id/parameter/1974.rdf" xlink:actuate="onRequest">pH_std_dev</gmx:Anchor>
        </gmd:keyword>
                <gmd:keyword>
          <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/dataset-parameter/1009352.rdf" xlink:title="http://lod.bco-dmo.org/id/parameter/707571.rdf" xlink:actuate="onRequest">measured_ConAC</gmx:Anchor>
        </gmd:keyword>
                <gmd:keyword>
          <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/dataset-parameter/1009353.rdf" xlink:title="http://lod.bco-dmo.org/id/parameter/1974.rdf" xlink:actuate="onRequest">measured_ConAC_std_dev</gmx:Anchor>
        </gmd:keyword>
                <gmd:keyword>
          <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/dataset-parameter/1009354.rdf" xlink:title="http://lod.bco-dmo.org/id/parameter/707571.rdf" xlink:actuate="onRequest">measured_CRAM</gmx:Anchor>
        </gmd:keyword>
                <gmd:keyword>
          <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/dataset-parameter/1009355.rdf" xlink:title="http://lod.bco-dmo.org/id/parameter/1974.rdf" xlink:actuate="onRequest">measured_CRAM_std_dev</gmx:Anchor>
        </gmd:keyword>
                <gmd:keyword>
          <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/dataset-instrument/1009360.rdf" xlink:title="http://lod.bco-dmo.org/id/instrument/681.rdf" xlink:actuate="onRequest">Thermo Orion Star Series benchtop conductivity meter</gmx:Anchor>
        </gmd:keyword>
                <gmd:keyword>
          <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/dataset-instrument/1009361.rdf" xlink:title="http://lod.bco-dmo.org/id/instrument/629842.rdf" xlink:actuate="onRequest">oven</gmx:Anchor>
        </gmd:keyword>
                <gmd:keyword>
          <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/dataset-instrument/1009363.rdf" xlink:title="http://lod.bco-dmo.org/id/instrument/506.rdf" xlink:actuate="onRequest">Agilent 1100 high-performance liquid chromatography system</gmx:Anchor>
        </gmd:keyword>
                <gmd:keyword>
          <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/dataset-instrument/1009368.rdf" xlink:title="http://lod.bco-dmo.org/id/instrument/892943.rdf" xlink:actuate="onRequest">flatbed SUNTEST CPS+ solar simulator</gmx:Anchor>
        </gmd:keyword>
                <gmd:keyword>
          <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/dataset-instrument/1009357.rdf" xlink:title="http://lod.bco-dmo.org/id/instrument/469.rdf" xlink:actuate="onRequest">spooling-wire microcombustion (SWiM) device interfaced with an isotope-ratio mass spectrometer (IRMS)</gmx:Anchor>
        </gmd:keyword>
                <gmd:keyword>
          <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/dataset-instrument/1009364.rdf" xlink:title="http://lod.bco-dmo.org/id/instrument/557097.rdf" xlink:actuate="onRequest">Bruker BioSpin AVANCE III spectrometer</gmx:Anchor>
        </gmd:keyword>
                <gmd:keyword>
          <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/dataset-instrument/1009356.rdf" xlink:title="http://lod.bco-dmo.org/id/instrument/906842.rdf" xlink:actuate="onRequest">Shimadzu TOC-VCPH</gmx:Anchor>
        </gmd:keyword>
                <gmd:keyword>
          <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/dataset-instrument/1009365.rdf" xlink:title="http://lod.bco-dmo.org/id/instrument/987728.rdf" xlink:actuate="onRequest">vortex mixer</gmx:Anchor>
        </gmd:keyword>
        <gmd:type>
            <gmd:MD_KeywordTypeCode codeList="http://www.isotc211.org/2005/resources/Codelist/gmxCodelists.xml#MD_KeywordTypeCode" codeListValue="theme" codeSpace="005">theme</gmd:MD_KeywordTypeCode>
          </gmd:type>
          <gmd:thesaurusName>
            <gmd:CI_Citation>
              <gmd:title>
                <gco:CharacterString>None, User defined</gco:CharacterString>
              </gmd:title>
              <gmd:date gco:nilReason="unknown"/>
            </gmd:CI_Citation>
          </gmd:thesaurusName>
        </gmd:MD_Keywords>
      </gmd:descriptiveKeywords>
            <gmd:descriptiveKeywords>
        <gmd:MD_Keywords>
                <gmd:keyword>
          <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/parameter/1838.rdf" xlink:title="Parameter" xlink:actuate="onRequest">time_elapsed</gmx:Anchor>
        </gmd:keyword>
                <gmd:keyword>
          <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/parameter/1188.rdf" xlink:title="Parameter" xlink:actuate="onRequest">dissolved organic Carbon</gmx:Anchor>
        </gmd:keyword>
                <gmd:keyword>
          <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/parameter/1974.rdf" xlink:title="Parameter" xlink:actuate="onRequest">standard deviation</gmx:Anchor>
        </gmd:keyword>
                <gmd:keyword>
          <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/parameter/671305.rdf" xlink:title="Parameter" xlink:actuate="onRequest">d13C</gmx:Anchor>
        </gmd:keyword>
                <gmd:keyword>
          <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/parameter/1892.rdf" xlink:title="Parameter" xlink:actuate="onRequest">pH</gmx:Anchor>
        </gmd:keyword>
                <gmd:keyword>
          <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/parameter/707571.rdf" xlink:title="Parameter" xlink:actuate="onRequest">Elemental carbon (C)</gmx:Anchor>
        </gmd:keyword>
        <gmd:type>
            <gmd:MD_KeywordTypeCode codeList="http://www.isotc211.org/2005/resources/Codelist/gmxCodelists.xml#MD_KeywordTypeCode" codeListValue="featureType">featureType</gmd:MD_KeywordTypeCode>
          </gmd:type>
          <gmd:thesaurusName>
            <gmd:CI_Citation>
              <gmd:title>
                <gco:CharacterString>BCO-DMO Standard Parameters</gco:CharacterString>
              </gmd:title>
              <gmd:date gco:nilReason="unknown"/>
            </gmd:CI_Citation>
          </gmd:thesaurusName>
        </gmd:MD_Keywords>
      </gmd:descriptiveKeywords>
            <gmd:descriptiveKeywords>
        <gmd:MD_Keywords>
                <gmd:keyword>
          <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/instrument/681.rdf" xlink:title="Instrument" xlink:actuate="onRequest">Benchtop pH Meter</gmx:Anchor>
        </gmd:keyword>
                <gmd:keyword>
          <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/instrument/629842.rdf" xlink:title="Instrument" xlink:actuate="onRequest">Drying Oven</gmx:Anchor>
        </gmd:keyword>
                <gmd:keyword>
          <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/instrument/506.rdf" xlink:title="Instrument" xlink:actuate="onRequest">High-Performance Liquid Chromatograph</gmx:Anchor>
        </gmd:keyword>
                <gmd:keyword>
          <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/instrument/892943.rdf" xlink:title="Instrument" xlink:actuate="onRequest">irradiation system</gmx:Anchor>
        </gmd:keyword>
                <gmd:keyword>
          <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/instrument/469.rdf" xlink:title="Instrument" xlink:actuate="onRequest">Isotope-ratio Mass Spectrometer</gmx:Anchor>
        </gmd:keyword>
                <gmd:keyword>
          <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/instrument/557097.rdf" xlink:title="Instrument" xlink:actuate="onRequest">Nuclear Magnetic Resonance Spectrometers</gmx:Anchor>
        </gmd:keyword>
                <gmd:keyword>
          <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/instrument/906842.rdf" xlink:title="Instrument" xlink:actuate="onRequest">Shimadzu Total Organic Carbon Analyzer TOC-VCPH</gmx:Anchor>
        </gmd:keyword>
                <gmd:keyword>
          <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/instrument/987728.rdf" xlink:title="Instrument" xlink:actuate="onRequest">vortex mixer</gmx:Anchor>
        </gmd:keyword>
        <gmd:type>
            <gmd:MD_KeywordTypeCode codeList="https://data.noaa.gov/resources/iso19139/schema/resources/Codelist/gmxCodelists.xml#MD_KeywordTypeCode" codeListValue="instrument">instrument</gmd:MD_KeywordTypeCode>
          </gmd:type>
          <gmd:thesaurusName>
            <gmd:CI_Citation>
              <gmd:title>
                <gco:CharacterString>BCO-DMO Standard Instruments</gco:CharacterString>
              </gmd:title>
              <gmd:date gco:nilReason="unknown"/>
            </gmd:CI_Citation>
          </gmd:thesaurusName>
        </gmd:MD_Keywords>
      </gmd:descriptiveKeywords>
      <gmd:resourceConstraints>
        <gmd:MD_LegalConstraints>
          <gmd:accessConstraints>
            <gmd:MD_RestrictionCode codeList="http://www.isotc211.org/2005/resources/Codelist/gmxCodelists.xml#MD_RestrictionCode" codeListValue="otherRestrictions" codeSpace="008">otherRestrictions</gmd:MD_RestrictionCode>
          </gmd:accessConstraints>
          <gmd:useConstraints>
            <gmd:MD_RestrictionCode codeList="http://www.isotc211.org/2005/resources/Codelist/gmxCodelists.xml#MD_RestrictionCode" codeListValue="otherRestrictions" codeSpace="008">otherRestrictions</gmd:MD_RestrictionCode>
          </gmd:useConstraints>
          <gmd:otherConstraints>
            <gco:CharacterString>Access Constraints: none. Use Constraints: Please follow guidelines at: http://www.bco-dmo.org/terms-use Distribution liability: Under no circumstances shall BCO-DMO be liable for any direct, incidental, special, consequential, indirect, or punitive damages that result from the use of, or the inability to use, the materials in this data submission. If you are dissatisfied with any materials in this data submission your sole and exclusive remedy is to discontinue use.</gco:CharacterString>
          </gmd:otherConstraints>
        </gmd:MD_LegalConstraints>
              </gmd:resourceConstraints>
      <gmd:aggregationInfo>
        <gmd:MD_AggregateInformation>
          <gmd:aggregateDataSetName>
              <gmd:CI_Citation>
                <gmd:title>
                  <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/project/941590.rdf" xlink:title="Project" xlink:actuate="onRequest">EAGER: The camouflaging of terrigenous organic matter as marine organic matter through hydroxyl radical oxidation via the dark Fenton reaction</gmx:Anchor>
                </gmd:title>
                <gmd:date gco:nilReason="inapplicable"/>
                <gmd:citedResponsibleParty>
                  <gmd:CI_ResponsibleParty>
                    <gmd:contactInfo>
                      <gmd:CI_Contact>
                        <gmd:onlineResource>
                          <gmd:CI_OnlineResource>
                          <gmd:linkage>
                            <gmd:URL>https://osprey.bco-dmo.org/project/941590</gmd:URL>
                          </gmd:linkage>
                          <gmd:name>
                            <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/project/941590.rdf" xlink:title="Project Name" xlink:actuate="onRequest">EAGER: The camouflaging of terrigenous organic matter as marine organic matter through hydroxyl radical oxidation via the dark Fenton reaction</gmx:Anchor>
                          </gmd:name>
                          <gmd:description>
                            <gco:CharacterString>&lt;p&gt;&lt;em&gt;NSF Award Abstract:&lt;/em&gt;&lt;br /&gt;
Organic carbon in the ocean is made-up of materials delivered by riverine runoff from land and marine sources. However, even though a large amount of land-derived organic carbon enters the ocean from rivers, most carbon in the ocean appears to be from marine sources. This has led scientists to conclude that land-derived carbon is not transported far into the ocean. This EAGER project aims to test this assumption. The team of scientists will examine whether chemical reactions alter the composition of land-derived organic carbon in a way that makes it look like marine organic carbon. If this proves true, the results could explain why land-derived organic carbon is difficult to identify in the ocean and could lead to a reconsideration of present carbon budgets and models. The scientists will perform experiments using land-derived carbon collected from major river systems throughout the world. Samples will be introduced to reactive oxygen species (mainly hydroxyl radicals) and iron in the dark under conditions that occur in nature. Reaction rates and changes in the composition of the organic matter will be monitored during and following the experiments. This EAGER project provides research training and valuable professional development experience for an early career researcher who has not received prior support from NSF. Undergraduate students enrolled in STEM and REU programs at the lead institutions will participate in the research.&lt;/p&gt;
&lt;p&gt;This EAGER project examines the hypothesis that hydroxyl radicals generated during dark Fenton reactions react with terrigenous organic matter to produce organic matter that is compositionally and isotopically similar to marine organic matter. The PIs will test this hypothesis using environmentally relevant concentrations of hydroxyl radical and terrestrial organic matter samples collected from several large-scale terrestrial riverine systems. The PIs will use multiple methods to characterize bulk organic matter (infrared/nuclear magnetic resonance (NMR) spectroscopy), its molecular composition (electrospray ionization Fourier Transform ion cyclotron resonance mass spectrometry (ESI FT-ICR MS), and stable isotope values of carbon and nitrogen (δ13C, δ15N) of dissolved and particulate organic matter pools before, during and following the experiments. This study explores an untested, but potentially transformative hypothesis that could alter existing paradigms about the fate of terrestrial organic matter in the ocean. Results from this study could revise understanding of the contributions of terrigenous organic matter to the ocean carbon cycle. The project would provide research and professional development opportunities for an early career investigator who has not received prior NSF support (co-PI Goranov). Undergraduates enrolled in REU and STEM training programs at the PIs’ home institutions would participate in the research.&lt;/p&gt;
&lt;p&gt;This award reflects NSF's statutory mission and has been deemed worthy of support through evaluation using the Foundation's intellectual merit and broader impacts review criteria.&lt;/p&gt;</gco:CharacterString>
                          </gmd:description>
                          <gmd:function>
                            <gmd:CI_OnLineFunctionCode codeList="http://www.isotc211.org/2005/resources/Codelist/gmxCodelists.xml#CI_OnLineFunctionCode" codeListValue="information"/>
                          </gmd:function>
                      </gmd:CI_OnlineResource>
                    </gmd:onlineResource>
                  </gmd:CI_Contact>
                </gmd:contactInfo>
                <gmd:role/>
              </gmd:CI_ResponsibleParty>
            </gmd:citedResponsibleParty>
          </gmd:CI_Citation>
        </gmd:aggregateDataSetName>
          <gmd:aggregateDataSetIdentifier>
            <gmd:MD_Identifier>
              <gmd:code>
                <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/project/941590.rdf" xlink:title="Project Acronym" xlink:actuate="onRequest">Fenton oxidation</gmx:Anchor>
              </gmd:code>
            </gmd:MD_Identifier>
          </gmd:aggregateDataSetIdentifier>
          <gmd:associationType>
            <gmd:DS_AssociationTypeCode codeList="https://data.noaa.gov/resources/iso19139/schema/resources/Codelist/gmxCodelists.xml#DS_AssociationTypeCode" codeListValue="largerWorkCitation">largerWorkCitation</gmd:DS_AssociationTypeCode>
          </gmd:associationType>
          <gmd:initiativeType>
            <gmd:DS_InitiativeTypeCode codeList="https://data.noaa.gov/resources/iso19139/schema/resources/Codelist/gmxCodelists.xml#DS_InitiativeTypeCode" codeListValue="project">project</gmd:DS_InitiativeTypeCode>
          </gmd:initiativeType>
        </gmd:MD_AggregateInformation>
      </gmd:aggregationInfo>
      <gmd:language>
        <gco:CharacterString>eng; USA</gco:CharacterString>
      </gmd:language>
      <gmd:topicCategory>
        <gmd:MD_TopicCategoryCode>biota</gmd:MD_TopicCategoryCode>
      </gmd:topicCategory>
       <gmd:topicCategory>
        <gmd:MD_TopicCategoryCode>oceans</gmd:MD_TopicCategoryCode>
      </gmd:topicCategory>
       <gmd:extent>
        <gmd:EX_Extent id="boundingExtent"><gmd:temporalElement>
            <gmd:EX_TemporalExtent>
              <gmd:extent>
                <gml:TimePeriod gml:id="boundingTemporalExtent">
                  <gml:beginPosition>2019-10-08</gml:beginPosition>
                  <gml:endPosition>2026-10-08</gml:endPosition>
                </gml:TimePeriod>
              </gmd:extent>
            </gmd:EX_TemporalExtent>
          </gmd:temporalElement>
          </gmd:EX_Extent>
      </gmd:extent>
      </gmd:MD_DataIdentification>
  </gmd:identificationInfo>
  <gmd:contentInfo>
    <gmd:MD_FeatureCatalogueDescription>
      <gmd:includedWithDataset>
        <gco:Boolean>0</gco:Boolean>
      </gmd:includedWithDataset>
      <gmd:featureCatalogueCitation>
        <gmd:CI_Citation>
          <gmd:title>
            <gco:CharacterString>BCO-DMO catalogue of parameters from Changes in dissolved organic carbon, stable carbon isotopes, pH, condensed aromatic carbon, and carboxyl-rich alicyclic molecules during laboratory photo-irradiation of vanillin</gco:CharacterString>
          </gmd:title>
          <gmd:date gco:nilReason="unknown"/>
          <gmd:citedResponsibleParty>
            <gmd:CI_ResponsibleParty>
  <gmd:organisationName>
    <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/affiliation/191.rdf" xlink:actuate="onRequest">Biological and Chemical Oceanography Data Management Office (BCO-DMO)</gmx:Anchor>
  </gmd:organisationName>
  <gmd:contactInfo>
    <gmd:CI_Contact>
		  <gmd:phone>
		    <gmd:CI_Telephone>
				  <gmd:voice>
				    <gco:CharacterString>Unavailable</gco:CharacterString>
				  </gmd:voice>
				  <gmd:facsimile>
				    <gco:CharacterString>508-289-2009</gco:CharacterString>
				  </gmd:facsimile>
				</gmd:CI_Telephone>
		  </gmd:phone>
		  <gmd:address>
		    <gmd:CI_Address>
				  <gmd:deliveryPoint>
				    <gco:CharacterString>WHOI MS#36</gco:CharacterString>
				  </gmd:deliveryPoint>
				  <gmd:city>
				    <gco:CharacterString>Woods Hole</gco:CharacterString>
				  </gmd:city>
				  <gmd:administrativeArea>
				    <gco:CharacterString>MA</gco:CharacterString>
				  </gmd:administrativeArea>
				  <gmd:postalCode>
				    <gco:CharacterString>02543</gco:CharacterString>
				  </gmd:postalCode>
				  <gmd:country>
				    <gco:CharacterString>USA</gco:CharacterString>
				  </gmd:country>
				  <gmd:electronicMailAddress>
				    <gco:CharacterString>info@bco-dmo.org</gco:CharacterString>
				  </gmd:electronicMailAddress>
		    </gmd:CI_Address>
		  </gmd:address>
      <gmd:onlineResource>
          <gmd:CI_OnlineResource>
            <gmd:linkage>
              <gmd:URL>http://www.bco-dmo.org</gmd:URL>
            </gmd:linkage>
          </gmd:CI_OnlineResource>
        </gmd:onlineResource>
		  <gmd:hoursOfService>
        <gco:CharacterString>Monday - Friday 8:00am - 5:00pm</gco:CharacterString>
      </gmd:hoursOfService>
		  <gmd:contactInstructions>
		    <gco:CharacterString>For questions regarding this resource, please contact BCO-DMO via the email address provided.</gco:CharacterString>
		  </gmd:contactInstructions>
		</gmd:CI_Contact>
  </gmd:contactInfo>
  <gmd:role>
    <gmd:CI_RoleCode codeList="http://www.isotc211.org/2005/resources/Codelist/gmxCodelists.xml#CI_RoleCode" codeListValue="pointOfContact"  codeSpace="007">pointOfContact</gmd:CI_RoleCode>
  </gmd:role>
</gmd:CI_ResponsibleParty>
          </gmd:citedResponsibleParty>
          <gmd:otherCitationDetails>
            <gco:CharacterString>
            http://lod.bco-dmo.org/id/dataset-parameter/1009345.rdf
	Name: laboratory_time
	Units: hours
	Description: &lt;p&gt;Time of irradiation; Cumulative duration of sample exposure recorded in 24-hour irradiation cycle increments&lt;/p&gt; 
http://lod.bco-dmo.org/id/dataset-parameter/1009346.rdf
	Name: measured_DOC
	Units: ppm-C
	Description: &lt;p&gt;Measured Dissolved Organic Carbon&lt;/p&gt; 
http://lod.bco-dmo.org/id/dataset-parameter/1009347.rdf
	Name: measured_DOC_std_dev
	Units: ppm-C
	Description: &lt;p&gt;Standard Deviation of the Measured [DOC]&lt;/p&gt; 
http://lod.bco-dmo.org/id/dataset-parameter/1009348.rdf
	Name: d13C
	Units: ‰
	Description: &lt;p&gt;Stable carbon isotopic signature&lt;/p&gt; 
http://lod.bco-dmo.org/id/dataset-parameter/1009349.rdf
	Name: d13C_std_dev
	Units: ‰
	Description: &lt;p&gt;Standard Deviation of the d13C&lt;/p&gt; 
http://lod.bco-dmo.org/id/dataset-parameter/1009350.rdf
	Name: pH
	Units: unitless
	Description: &lt;p&gt;pH&lt;/p&gt; 
http://lod.bco-dmo.org/id/dataset-parameter/1009351.rdf
	Name: pH_std_dev
	Units: unitless
	Description: &lt;p&gt;Standard Deviation of the pH&lt;/p&gt; 
http://lod.bco-dmo.org/id/dataset-parameter/1009352.rdf
	Name: measured_ConAC
	Units: ppm-C
	Description: &lt;p&gt;Condensed aromatic carbon (ConAC) concentration&lt;/p&gt; 
http://lod.bco-dmo.org/id/dataset-parameter/1009353.rdf
	Name: measured_ConAC_std_dev
	Units: ppm-C
	Description: &lt;p&gt;Standard deviation of replicate ConAC measurements&lt;/p&gt; 
http://lod.bco-dmo.org/id/dataset-parameter/1009354.rdf
	Name: measured_CRAM
	Units: ppm-C
	Description: &lt;p&gt;Carboxyl-rich alicyclic molecule (CRAM) carbon concentration&lt;/p&gt; 
http://lod.bco-dmo.org/id/dataset-parameter/1009355.rdf
	Name: measured_CRAM_std_dev
	Units: ppm-C
	Description: &lt;p&gt;Standard deviation of replicate CRAM measurements&lt;/p&gt; 
</gco:CharacterString>
          </gmd:otherCitationDetails>
        </gmd:CI_Citation>
      </gmd:featureCatalogueCitation>
      <gmd:featureCatalogueCitation>
        <gmd:CI_Citation>
          <gmd:title>
            <gco:CharacterString>GB/NERC/BODC &gt; British Oceanographic Data Centre, Natural Environment Research Council, United Kingdom</gco:CharacterString>
          </gmd:title>
          <gmd:date gco:nilReason="unknown"/>
          <gmd:citedResponsibleParty xlink:href="https://data.noaa.gov/docucomp/3D8FE2C9DA324D40939C8D007587E011" xlink:title="GB/NERC/BODC &gt; British Oceanographic Data Centre, Natural Environment Research Council, United Kingdom"/>
          <gmd:otherCitationDetails>
            <gco:CharacterString>
            </gco:CharacterString>
          </gmd:otherCitationDetails>
        </gmd:CI_Citation>
      </gmd:featureCatalogueCitation>
    </gmd:MD_FeatureCatalogueDescription>
  </gmd:contentInfo>
  <gmd:distributionInfo>
    <gmd:MD_Distribution>
      <gmd:distributor>
        <gmd:MD_Distributor>
          <gmd:distributorContact>
            <gmd:CI_ResponsibleParty>
  <gmd:organisationName>
    <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/affiliation/191.rdf" xlink:actuate="onRequest">Biological and Chemical Oceanography Data Management Office (BCO-DMO)</gmx:Anchor>
  </gmd:organisationName>
  <gmd:contactInfo>
    <gmd:CI_Contact>
		  <gmd:phone>
		    <gmd:CI_Telephone>
				  <gmd:voice>
				    <gco:CharacterString>Unavailable</gco:CharacterString>
				  </gmd:voice>
				  <gmd:facsimile>
				    <gco:CharacterString>508-289-2009</gco:CharacterString>
				  </gmd:facsimile>
				</gmd:CI_Telephone>
		  </gmd:phone>
		  <gmd:address>
		    <gmd:CI_Address>
				  <gmd:deliveryPoint>
				    <gco:CharacterString>WHOI MS#36</gco:CharacterString>
				  </gmd:deliveryPoint>
				  <gmd:city>
				    <gco:CharacterString>Woods Hole</gco:CharacterString>
				  </gmd:city>
				  <gmd:administrativeArea>
				    <gco:CharacterString>MA</gco:CharacterString>
				  </gmd:administrativeArea>
				  <gmd:postalCode>
				    <gco:CharacterString>02543</gco:CharacterString>
				  </gmd:postalCode>
				  <gmd:country>
				    <gco:CharacterString>USA</gco:CharacterString>
				  </gmd:country>
				  <gmd:electronicMailAddress>
				    <gco:CharacterString>info@bco-dmo.org</gco:CharacterString>
				  </gmd:electronicMailAddress>
		    </gmd:CI_Address>
		  </gmd:address>
      <gmd:onlineResource>
          <gmd:CI_OnlineResource>
            <gmd:linkage>
              <gmd:URL>http://www.bco-dmo.org</gmd:URL>
            </gmd:linkage>
          </gmd:CI_OnlineResource>
        </gmd:onlineResource>
		  <gmd:hoursOfService>
        <gco:CharacterString>Monday - Friday 8:00am - 5:00pm</gco:CharacterString>
      </gmd:hoursOfService>
		  <gmd:contactInstructions>
		    <gco:CharacterString>For questions regarding this resource, please contact BCO-DMO via the email address provided.</gco:CharacterString>
		  </gmd:contactInstructions>
		</gmd:CI_Contact>
  </gmd:contactInfo>
  <gmd:role>
    <gmd:CI_RoleCode codeList="http://www.isotc211.org/2005/resources/Codelist/gmxCodelists.xml#CI_RoleCode" codeListValue="pointOfContact"  codeSpace="007">pointOfContact</gmd:CI_RoleCode>
  </gmd:role>
</gmd:CI_ResponsibleParty>
          </gmd:distributorContact>
        </gmd:MD_Distributor>
      </gmd:distributor>
      <gmd:transferOptions>
        <gmd:MD_DigitalTransferOptions>
        <gmd:onLine>
            <gmd:CI_OnlineResource>
              <gmd:linkage>
                <gmd:URL>https://osprey.bco-dmo.org/dataset/1009323/data/download</gmd:URL>
              </gmd:linkage>
              <gmd:function>
                <gmd:CI_OnLineFunctionCode codeList="https://data.noaa.gov/resources/iso19139/schema/resources/Codelist/gmxCodelists.xml#CI_OnLineFunctionCode" codeListValue="download">download</gmd:CI_OnLineFunctionCode>
              </gmd:function>
            </gmd:CI_OnlineResource>
          </gmd:onLine>
        <gmd:offLine>
            <gmd:MD_Medium>
              <gmd:name>
                 <gmd:MD_MediumNameCode codeList="https://data.noaa.gov/resources/iso19139/schema/resources/Codelist/gmxCodelists.xml#MD_MediumNameCode" codeListValue="onLine">onLine</gmd:MD_MediumNameCode>
              </gmd:name>
            </gmd:MD_Medium>
          </gmd:offLine>
        </gmd:MD_DigitalTransferOptions>
      </gmd:transferOptions>
    </gmd:MD_Distribution>
  </gmd:distributionInfo>
  <gmd:dataQualityInfo>
    <gmd:DQ_DataQuality>
      <gmd:scope>
        <gmd:DQ_Scope>
          <gmd:level>
            <gmd:MD_ScopeCode codeList="https://data.noaa.gov/resources/iso19139/schema/resources/Codelist/gmxCodelists.xml#MD_ScopeCode" codeListValue="dataset">dataset</gmd:MD_ScopeCode>
          </gmd:level>
        </gmd:DQ_Scope>
      </gmd:scope>
            <gmd:lineage>
        <gmd:LI_Lineage>
          <gmd:processStep xlink:title="Methods and Sampling">
            <gmd:LI_ProcessStep>
              <gmd:description>
                <gco:CharacterString>&amp;lt;p&amp;gt;Vanillin (Acros, 99%), a lignin monophenol, was chosen as a representative monomeric unit of lignin, a major component of tDOM (Opsahl and Benner, 1998). A solution of 20 mg-C of vanillin in 1 L ultrapure MilliQ water was prepared to serve as a stock solution in photochemical experiments. This concentration was chosen because it is representative to carbon contents in upstream terrestrial aquatic environments such as rivers and lakes (Gonsior et al., 2009).&amp;lt;/p&amp;gt;

&amp;lt;p&amp;gt;&amp;lt;strong&amp;gt;Photo-irradiation.&amp;amp;nbsp;&amp;lt;/strong&amp;gt;Approximately 350 mL of vanillin stock solution was aliquoted into a pre-combusted 500 mL quartz round-bottom flask capped with a pre-combusted glass cap. An aliquot of the stock solution was immediately wrapped with aluminum foil and stored at room temperature as a dark control. Another aliquot of the stock solution was frozen to evaluate the stability of the dark control at room temperature. Up to three 500 mL quartz flasks were placed in a flatbed SUNTEST CPS+ solar simulator equipped with a daylight UV glass filter (ATLAS Cat. No. 56052371, cutoff at ~290 nm) for simulating solar radiation outdoors. Irradiation was performed under controlled chamber air temperature of 35 °C&amp;amp;nbsp;in 24-hour cycles using power of 250 W/m&amp;lt;sup&amp;gt;2&amp;lt;/sup&amp;gt; yielding ~21,600 kJ/m&amp;lt;sup&amp;gt;2&amp;lt;/sup&amp;gt; per 24 hours. Flasks were irradiated for 24 hours and then opened for 30 minutes during which they were aerated and gently stirred. During this aeration step, a 20-, 40-, or 50-mL subsample was taken out for analyses. To keep the same total volume throughout the irradiation (350 mL), the same amount of ultrapure water was added back. Multiple irradiation experiments were performed to yield sufficient sample volumes for the different analytical methods employed for the characterization of the photo-products.&amp;amp;nbsp;&amp;lt;/p&amp;gt;

&amp;lt;p&amp;gt;&amp;lt;strong&amp;gt;Dissolved organic carbon.&amp;amp;nbsp;&amp;lt;/strong&amp;gt;Dissolved organic matter was quantified as dissolved organic carbon (DOC) equivalents (in mg-C/L) on a Shimadzu TOC-VCPH instrument following standard operating procedures. Briefly, samples were acidified and sparged with air for 3 minutes to remove any inorganic carbon species (dissolved CO, CO2, HCO3-, CO32-) or other dissolved volatile gases (e.g., CH4). Then, samples were injected in a high temperature combustion reactor (720 ˚C) to oxidize the DOM to CO2. Detection of CO2 is achieved using a non-dispersive infrared detector. DOC concentrations were quantified using standard calibration curves made with potassium hydrogen phthalate (Nacalai Tesque, JIS special grade).&amp;lt;/p&amp;gt;

&amp;lt;p&amp;gt;&amp;lt;strong&amp;gt;Stable carbon isotopic composition (δ13C&amp;lt;/strong&amp;gt;). Photo-irradiated solutions of vanillin were aliquoted to Falcon® tubes that were pre-aged in 2 % (w/w) NaOH for one month to remove any leachable carbon. Samples were freeze-dried and resuspended in ultrapure water to yield concentrated solutions necessary for analysis on a spooling-wire microcombustion (SWiM) device (Sessions et al. 2005) interfaced with an isotope-ratio mass spectrometer (IRMS) to determine the ratio of 13C to 12C atoms expressed in a delta notation (δ13C) and referenced to Vienna Pee Dee Belemnite (Camin et al. 2025).&amp;lt;/p&amp;gt;

&amp;lt;p&amp;gt;The SWiM system used has been employed previously to measure δ¹³C values of aqueous samples (Mohr et al. 2014). The SWiM interface is connected to a ThermoFinnigan DeltaPlus Advantage IRMS via an open split. Reference CO₂ is controlled using a Conflo III, and data are collected and analyzed using Isodat v3.0.&amp;amp;nbsp; Each analytical run begins with three pulses of standard CO₂ reference gas and ends with two pulses of standard CO₂ reference gas. Samples were injected in 1 μL aliquots, separated by 30 sec; 3 to 5 injections are made of each sample.&amp;amp;nbsp; All data are corrected assuming linear drift of the m/z 45/44 ratio over the duration of the run. Each run includes samples (unknowns) and standard dilution series of two laboratory reference materials (dextrose, -11.2‰, and nor-leucine, -27.7‰). Empty tube blanks containing ultrapure water are also measured. Directly measured blank δ¹³C values were smaller than values inferred from the dilution series, determined by the intersection of δ¹³C versus Area-1 for the two dilution series, which intersect at Area-1 and δ¹³C of the blank. All samples were subsequently blank-corrected using the intersection of these two lines.&amp;lt;/p&amp;gt;

&amp;lt;p&amp;gt;&amp;lt;strong&amp;gt;pH&amp;lt;/strong&amp;gt;. pH measurements were performed using a Thermo Orion Star Series benchtop conductivity meter on unirradiated and irradiated vanillin solutions. The pH meter was calibrated daily with pH 4.01 buffer solution (YSI 3821), pH 7.00 buffer solution (YSI 3822), and pH 10.00 buffer solution (YSI 3823).&amp;lt;/p&amp;gt;

&amp;lt;p&amp;gt;&amp;lt;strong&amp;gt;Condensed aromatic carbon (ConAC).&amp;lt;/strong&amp;gt;&amp;amp;nbsp;Exactly 40 mL of vanillin control and photochemically processed samples were freeze-dried. The obtained residue was redissolved in 2 mL of 1:1 methanol:water and transferred to 2-mL glass ampules. The solvent was evaporated at 60 °C and the residue was mixed with 0.5 mL concentrated nitric acid (65 %). Ampoules were flame-sealing and then samples were digested in an oven at 160°C for 6 hours. After this thermal digestion, the nitric acid was evaporated at 70°C in a sand bath under a stream of ultrapure nitrogen. The residue was redissolved in 0.5 mL of 0.6 mol L⁻¹ H₃PO₄ and filtered through a 0.2 µm syringe filter (Thermo Scientific™ Titan3™ PTFE). Benzenepentacarboxylic acid (B5CA, C₁₁H₆O₁₀) and benzenehexacarboxylic acid (B6CA, C₁₂H₆O₁₂) were quantified using an Agilent 1100 high-performance liquid chromatography system (Wagner et al. 2017). Their concentrations were then converted to carbon concentrations (i.e., B6CAC and B5CAC) and used to estimate the ConAC content of the original sample prior to digestion by multiplying by a scaling factor of 7.04 (Bostick et al., 2018) followed by normalization to organic carbon content. The molar ratio of B6CA to B5CA was also calculated to serve as an indicator of the degree of condensation of ConAC.&amp;amp;nbsp;&amp;lt;/p&amp;gt;

&amp;lt;p&amp;gt;&amp;lt;strong&amp;gt;Carboxyl-rich alicyclic molecules (CRAM).&amp;amp;nbsp;&amp;lt;/strong&amp;gt;Carboxyl-rich alicyclic molecules (CRAM) were quantified using liquid-state 1H NMR spectroscopy. Analyses were performed at room temperature (24.9 ± 0.1 °C) on a 400 MHz (9.4 Tesla) Bruker BioSpin AVANCE III spectrometer fitted with a double-resonance broadband inverse (BBI) probe at the College of Sciences Major Instrumentation Cluster (COSMIC) facility of Old Dominion University (Norfolk, VA). Instrument control and data processing were performed using the TopSpin software. Analyses were performed without pre-concentration (e.g., via solid-phase extraction) or filtering on aliquots of samples taken at different time points. Samples were prepared by mixing a 516-µL aliquot of the sample with 60 µL deuterated water (Acros Organics, 99.9% D, CAN RN 7789-20-0) to produce a 90:10 H2O:D2O solution necessary for obtaining a deuterium lock. Additionally, sodium 2,2,3,3-tetradeutero-3-trimethylsilylpropanoate was added (24 µL of 25 µM solution; Acros Organics, 98% D) to serve as an internal standard. Once all aliquots were added to an NMR tube, they were mixed using a vortex mixer. NMR tubes were pre-cleaned by soaking in aqua regia for 2+ weeks. Prior to use, each NMR tube is rinsed with ~250 mL of ultrapure water and dried at 60 °C to ensure no contamination.&amp;lt;/p&amp;gt;

&amp;lt;p&amp;gt;One-dimensional (1D) quantitative 1H spectra were acquired using the PEW5shapepr pulse program, which utilizes Perfect Echo - WATERGATE and shaped presaturation techniques for water suppression (Adams et al., 2013, Whitty et al., 2019). The employment of this pulse sequence results in quantitative spectra, with the water resonance at 4.7 ppm being suppressed. The relaxation delay (D1) employed for all quantitative analyses was 13.5 s, which was determined after an inversion-recovery experiment. For each individual sample the 90° excitation pulse width (P1) and transmitter offset (O1) were optimized to ensure quantitativeness of the signals. The obtained free-induction decay of 4096 summed transients was zero-filled to a 16k-sized dataset and apodized using a 10-Hz Lorentzian window function.&amp;amp;nbsp;&amp;lt;/p&amp;gt;

&amp;lt;p&amp;gt;&amp;lt;strong&amp;gt;Additional Data&amp;lt;/strong&amp;gt;&amp;amp;nbsp;&amp;lt;/p&amp;gt;

&amp;lt;p&amp;gt;Additional spectroscopic and mass spectrometric data is available from the authors upon request.&amp;lt;/p&amp;gt;</gco:CharacterString>
              </gmd:description>
              <gmd:source>
                <gmd:LI_Source>
                  <gmd:sourceCitation>
                    <gmd:CI_Citation>
                      <gmd:title>
                        <gco:CharacterString>Specified by the Principal Investigator(s)</gco:CharacterString>
                      </gmd:title>
                      <gmd:date gco:nilReason="unknown"/>
                    </gmd:CI_Citation>
                  </gmd:sourceCitation>
                </gmd:LI_Source>
              </gmd:source>
            </gmd:LI_ProcessStep>
          </gmd:processStep>
          <gmd:processStep xlink:title="Data Processing Description">
            <gmd:LI_ProcessStep>
              <gmd:description>
                <gco:CharacterString>&amp;lt;p&amp;gt;Data were processed in Microsoft Excel.&amp;amp;nbsp;&amp;lt;/p&amp;gt;

&amp;lt;p&amp;gt;NMR spectra were processed using the TopSpin software. First, spectra were calibrated, phased, and baseline-corrected. Then, spectra were integrated in the following regions: CH&amp;lt;sub&amp;gt;3&amp;lt;/sub&amp;gt; (0.6 – 0.91 ppm), CRAM (0.91 – 3.15 ppm), HC-O-R (3.15 – 4.4 ppm), olefinic (5 – 6.5 ppm), aromatic (6.5 – 8.3 ppm), and CHO (8.3 – 10 ppm). Formate (~8.3 ppm), methanol (3.34 ppm), and acetate (~1.9 ppm) were also independently integrated following manual inspection of each spectrum. They were subtracted from the region they resonate at: for example, acetate (resonating at ~1.9 ppm) is removed from the CRAM region (0.91-3.15 ppm). The CRAM region range has been previously determined by McKee et al. 2024. All integrals were also corrected for minor background signals using blank correction obtained from the analysis of pure vanillin in ultrapure water.&amp;lt;/p&amp;gt;

&amp;lt;p&amp;gt;To be able to use &amp;lt;sup&amp;gt;1&amp;lt;/sup&amp;gt;H NMR data for dissolved organic matter analysis (which is done via DOC, i.e., on a C-basis), the integrals (which are on H-basis as they originate from &amp;lt;sup&amp;gt;1&amp;lt;/sup&amp;gt;H spectra) were converted into C-basis integrals by multiplication with H/C molar ratios as following: 3 for CH&amp;lt;sub&amp;gt;3&amp;lt;/sub&amp;gt;, 1 for CRAM (McKee et al. 2024), 1.1 for HC-O-R (Decesari et al., 2007), 1 for olefinic, 0.4 for aromatic (Decesari et al. 2007), and 1 for CHO.&amp;amp;nbsp;&amp;lt;/p&amp;gt;</gco:CharacterString>
              </gmd:description>
              <gmd:source>
                <gmd:LI_Source>
                  <gmd:sourceCitation>
                    <gmd:CI_Citation>
                      <gmd:title>
                        <gco:CharacterString>Specified by the Principal Investigator(s)</gco:CharacterString>
                      </gmd:title>
                      <gmd:date gco:nilReason="unknown"/>
                    </gmd:CI_Citation>
                  </gmd:sourceCitation>
                </gmd:LI_Source>
              </gmd:source>
            </gmd:LI_ProcessStep>
          </gmd:processStep>
        <gmd:processStep xlink:title="BCO-DMO Data Curation Notes">
              <gmd:LI_ProcessStep>
                <gmd:description>
                  <gco:CharacterString>This section documents curation actions performed prior to publication review with the submitter, and additional information relevant to understanding and reusing this dataset. It distinguishes changes made to the submitted (meta)data from unresolved issues and/or enhancements that improve future reuse and interoperability.

CURATION ACTIONS PERFORMED ON DATA

- Loaded Data for BCO-DMO repository.xlsx (Sheet1, header row 1), using filename as resource name; set missing value sentinels to &amp;quot;&amp;quot;, &amp;quot;nd&amp;quot;, &amp;quot;ND&amp;quot;, &amp;quot;N.D.&amp;quot;
- Renamed columns: &amp;quot;Laboratory time, hours&amp;quot; to laboratory_time, &amp;quot;Measured [DOC], ppm-C&amp;quot; to measured_DOC, &amp;quot;Measured [DOC] Standard Deviation&amp;quot; to measured_DOC_std_dev, &amp;quot;d13C Standard Deviation&amp;quot; to d13C_std_dev, &amp;quot;pH Standard Deviation&amp;quot; to pH_std_dev, &amp;quot;Measured ConAC (ppm-C)&amp;quot; to measured_ConAC, &amp;quot;Measured ConAC Standard Deviation&amp;quot; to measured_ConAC_std_dev, &amp;quot;Measured CRAM (ppm-C)&amp;quot; to measured_CRAM, &amp;quot;Measured CRAM Standard Deviation&amp;quot; to measured_CRAM_std_dev (d13C and pH kept unchanged since names already matched targets)
- Output file as 1009323_v1_doc_degradation_incubation.csv

CURATION ACTIONS PERFORMED ON METADATA

- BCO-DMO's standard metadata entry and text formatting steps were performed. See: https://www.bco-dmo.org/how-to/standard-curation-edits
- Included information from instrument descriptions in the methods section
- Expanded parameter definitions for clarity

ISSUES POTENTIALLY IMPACTING REUSE

- Dataset values seem to be derived values, based on the observations. The complete data is not referenced or provided as part of this submission.
- Metadata does not state whether a dilution correction was applied to reported concentrations to account for the ultrapure water added back after each 30-minute aeration/subsampling step to maintain the 350 mL total volume, nor how such a correction would be calculated; metadata does not clarify whether the reported parameter values represent raw measured concentrations or values adjusted for this dilution effect.
- Metadata does not specify how many independent irradiation experiments (replicates) were conducted.</gco:CharacterString>
                </gmd:description>
                <gmd:source>
                  <gmd:LI_Source>
                    <gmd:sourceCitation>
                      <gmd:CI_Citation>
                        <gmd:title>
                          <gco:CharacterString>Specified by BCO-DMO Data Managers</gco:CharacterString>
                        </gmd:title>
                        <gmd:date gco:nilReason="unknown"/>
                      </gmd:CI_Citation>
                    </gmd:sourceCitation>
                  </gmd:LI_Source>
                </gmd:source>
              </gmd:LI_ProcessStep>
            </gmd:processStep>
          </gmd:LI_Lineage>
      </gmd:lineage>
   </gmd:DQ_DataQuality>
  </gmd:dataQualityInfo>
  <gmd:metadataMaintenance>
    <gmd:MD_MaintenanceInformation>
      <gmd:maintenanceAndUpdateFrequency>
        <gmd:MD_MaintenanceFrequencyCode codeList="http://www.isotc211.org/2005/resources/Codelist/gmxCodelists.xml#MD_MaintenanceFrequencyCode" codeListValue="asNeeded" codeSpace="009">asNeeded</gmd:MD_MaintenanceFrequencyCode>
      </gmd:maintenanceAndUpdateFrequency>
      <gmd:maintenanceNote>
        <gco:CharacterString>7.x-1.1</gco:CharacterString>
      </gmd:maintenanceNote>
      <gmd:contact>
        <gmd:CI_ResponsibleParty>
  <gmd:organisationName>
    <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/affiliation/191.rdf" xlink:actuate="onRequest">Biological and Chemical Oceanography Data Management Office (BCO-DMO)</gmx:Anchor>
  </gmd:organisationName>
  <gmd:contactInfo>
    <gmd:CI_Contact>
		  <gmd:phone>
		    <gmd:CI_Telephone>
				  <gmd:voice>
				    <gco:CharacterString>Unavailable</gco:CharacterString>
				  </gmd:voice>
				  <gmd:facsimile>
				    <gco:CharacterString>508-289-2009</gco:CharacterString>
				  </gmd:facsimile>
				</gmd:CI_Telephone>
		  </gmd:phone>
		  <gmd:address>
		    <gmd:CI_Address>
				  <gmd:deliveryPoint>
				    <gco:CharacterString>WHOI MS#36</gco:CharacterString>
				  </gmd:deliveryPoint>
				  <gmd:city>
				    <gco:CharacterString>Woods Hole</gco:CharacterString>
				  </gmd:city>
				  <gmd:administrativeArea>
				    <gco:CharacterString>MA</gco:CharacterString>
				  </gmd:administrativeArea>
				  <gmd:postalCode>
				    <gco:CharacterString>02543</gco:CharacterString>
				  </gmd:postalCode>
				  <gmd:country>
				    <gco:CharacterString>USA</gco:CharacterString>
				  </gmd:country>
				  <gmd:electronicMailAddress>
				    <gco:CharacterString>info@bco-dmo.org</gco:CharacterString>
				  </gmd:electronicMailAddress>
		    </gmd:CI_Address>
		  </gmd:address>
      <gmd:onlineResource>
          <gmd:CI_OnlineResource>
            <gmd:linkage>
              <gmd:URL>http://www.bco-dmo.org</gmd:URL>
            </gmd:linkage>
          </gmd:CI_OnlineResource>
        </gmd:onlineResource>
		  <gmd:hoursOfService>
        <gco:CharacterString>Monday - Friday 8:00am - 5:00pm</gco:CharacterString>
      </gmd:hoursOfService>
		  <gmd:contactInstructions>
		    <gco:CharacterString>For questions regarding this resource, please contact BCO-DMO via the email address provided.</gco:CharacterString>
		  </gmd:contactInstructions>
		</gmd:CI_Contact>
  </gmd:contactInfo>
  <gmd:role>
    <gmd:CI_RoleCode codeList="http://www.isotc211.org/2005/resources/Codelist/gmxCodelists.xml#CI_RoleCode" codeListValue="pointOfContact"  codeSpace="007">pointOfContact</gmd:CI_RoleCode>
  </gmd:role>
</gmd:CI_ResponsibleParty>
      </gmd:contact>
    </gmd:MD_MaintenanceInformation>
  </gmd:metadataMaintenance>
  <gmi:acquisitionInformation>
    <gmi:MI_AcquisitionInformation>
    <gmi:instrument>
        <gmi:MI_Instrument>
          <gmi:identifier>
            <gmd:MD_Identifier>
              <gmd:code>
                <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/instrument/681.rdf" xlink:title="Benchtop pH Meter" xlink:actuate="onRequest">Thermo Orion Star Series benchtop conductivity meter</gmx:Anchor>
              </gmd:code>
            </gmd:MD_Identifier>
          </gmi:identifier>
          <gmi:type>
            <gco:CharacterString>Thermo Orion Star Series benchtop conductivity meter</gco:CharacterString>
          </gmi:type>
          <gmi:description>
            <gco:CharacterString>PI Supplied Instrument Name: Thermo Orion Star Series benchtop conductivity meter PI Supplied Instrument Description:pH measurements were performed using a Thermo Orion Star Series benchtop conductivity meter on unirradiated and irradiated vanillin solutions. The pH meter was calibrated daily with pH 4.01 buffer solution (YSI 3821), pH 7.00 buffer solution (YSI 3822), and pH 10.00 buffer solution (YSI 3823). Instrument Name: Benchtop pH Meter Instrument Short Name:Benchtop pH Meter   Instrument Description: An instrument consisting of an electronic voltmeter and pH-responsive electrode that gives a direct conversion of voltage differences to differences of pH at the measurement temperature.  (McGraw-Hill Dictionary of Scientific and Technical Terms) 
This instrument does not map to the NERC instrument vocabulary term for 'pH Sensor' which measures values in the water column.  Benchtop models are typically employed for stationary lab applications.</gco:CharacterString>
          </gmi:description>
        </gmi:MI_Instrument>
      </gmi:instrument>
      <gmi:instrument>
        <gmi:MI_Instrument>
          <gmi:identifier>
            <gmd:MD_Identifier>
              <gmd:code>
                <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/instrument/629842.rdf" xlink:title="Drying Oven" xlink:actuate="onRequest">oven</gmx:Anchor>
              </gmd:code>
            </gmd:MD_Identifier>
          </gmi:identifier>
          <gmi:type>
            <gco:CharacterString>oven</gco:CharacterString>
          </gmi:type>
          <gmi:description>
            <gco:CharacterString>PI Supplied Instrument Name: oven PI Supplied Instrument Description:Ampoules were flame-sealing and then samples were digested in an oven at 160°C for 6 hours. Instrument Name: Drying Oven Instrument Short Name:   Instrument Description:  a heated chamber for drying</gco:CharacterString>
          </gmi:description>
        </gmi:MI_Instrument>
      </gmi:instrument>
      <gmi:instrument>
        <gmi:MI_Instrument>
          <gmi:identifier>
            <gmd:MD_Identifier>
              <gmd:code>
                <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/instrument/506.rdf" xlink:title="High-Performance Liquid Chromatograph" xlink:actuate="onRequest">Agilent 1100 high-performance liquid chromatography system</gmx:Anchor>
              </gmd:code>
            </gmd:MD_Identifier>
          </gmi:identifier>
          <gmi:type>
            <gco:CharacterString>Agilent 1100 high-performance liquid chromatography system</gco:CharacterString>
          </gmi:type>
          <gmi:description>
            <gco:CharacterString>PI Supplied Instrument Name: Agilent 1100 high-performance liquid chromatography system PI Supplied Instrument Description:Benzenepentacarboxylic acid (B5CA, C₁₁H₆O₁₀) and benzenehexacarboxylic acid (B6CA, C₁₂H₆O₁₂) were quantified using an Agilent 1100 high-performance liquid chromatography system (Wagner et al. 2017). Instrument Name: High-Performance Liquid Chromatograph Instrument Short Name:HPLC   Instrument Description: A High-performance liquid chromatograph (HPLC) is a type of liquid chromatography used to separate compounds that are dissolved in solution. HPLC instruments consist of a reservoir of the mobile phase, a pump, an injector, a separation column, and a detector. Compounds are separated by high pressure pumping of the sample mixture onto a column packed with microspheres coated with the stationary phase. The different components in the mixture pass through the column at different rates due to differences in their partitioning behavior between the mobile liquid phase and the stationary phase. Community Standard Description: http://vocab.nerc.ac.uk/collection/L05/current/LAB11/</gco:CharacterString>
          </gmi:description>
        </gmi:MI_Instrument>
      </gmi:instrument>
      <gmi:instrument>
        <gmi:MI_Instrument>
          <gmi:identifier>
            <gmd:MD_Identifier>
              <gmd:code>
                <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/instrument/892943.rdf" xlink:title="irradiation system" xlink:actuate="onRequest">flatbed SUNTEST CPS+ solar simulator</gmx:Anchor>
              </gmd:code>
            </gmd:MD_Identifier>
          </gmi:identifier>
          <gmi:type>
            <gco:CharacterString>flatbed SUNTEST CPS+ solar simulator</gco:CharacterString>
          </gmi:type>
          <gmi:description>
            <gco:CharacterString>PI Supplied Instrument Name: flatbed SUNTEST CPS+ solar simulator PI Supplied Instrument Description:Up to three 500 mL quartz flasks were placed in a flatbed SUNTEST CPS+ solar simulator equipped with a daylight UV glass filter (ATLAS Cat. No. 56052371, cutoff at ~290 nm) for simulating solar radiation outdoors.  Instrument Name: irradiation system Instrument Short Name:   Instrument Description: A system of instruments/devices that provide irradiation of materials. Irradiation is an energy transfer process during which a material entity receives energy through radiation.</gco:CharacterString>
          </gmi:description>
        </gmi:MI_Instrument>
      </gmi:instrument>
      <gmi:instrument>
        <gmi:MI_Instrument>
          <gmi:identifier>
            <gmd:MD_Identifier>
              <gmd:code>
                <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/instrument/469.rdf" xlink:title="Isotope-ratio Mass Spectrometer" xlink:actuate="onRequest">spooling-wire microcombustion (SWiM) device interfaced with an isotope-ratio mass spectrometer (IRMS)</gmx:Anchor>
              </gmd:code>
            </gmd:MD_Identifier>
          </gmi:identifier>
          <gmi:type>
            <gco:CharacterString>spooling-wire microcombustion (SWiM) device interfaced with an isotope-ratio mass spectrometer (IRMS)</gco:CharacterString>
          </gmi:type>
          <gmi:description>
            <gco:CharacterString>PI Supplied Instrument Name: spooling-wire microcombustion (SWiM) device interfaced with an isotope-ratio mass spectrometer (IRMS) PI Supplied Instrument Description:Samples were freeze-dried and resuspended in ultrapure water to yield concentrated solutions necessary for analysis on a spooling-wire microcombustion (SWiM) device (Sessions et al., 2005) interfaced with an isotope-ratio mass spectrometer (IRMS) to determine the ratio of 13C to 12C atoms expressed in a delta notation (δ13C) and referenced to Vienna Pee Dee Belemnite (Camin et al. 2025). Instrument Name: Isotope-ratio Mass Spectrometer Instrument Short Name:IR Mass Spec; IRMS   Instrument Description: The Isotope-ratio Mass Spectrometer is a particular type of mass spectrometer used to measure the relative abundance of isotopes in a given sample (e.g. VG Prism II Isotope Ratio Mass-Spectrometer). Community Standard Description: http://vocab.nerc.ac.uk/collection/L05/current/LAB16/</gco:CharacterString>
          </gmi:description>
        </gmi:MI_Instrument>
      </gmi:instrument>
      <gmi:instrument>
        <gmi:MI_Instrument>
          <gmi:identifier>
            <gmd:MD_Identifier>
              <gmd:code>
                <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/instrument/557097.rdf" xlink:title="Nuclear Magnetic Resonance Spectrometers" xlink:actuate="onRequest">Bruker BioSpin AVANCE III spectrometer</gmx:Anchor>
              </gmd:code>
            </gmd:MD_Identifier>
          </gmi:identifier>
          <gmi:type>
            <gco:CharacterString>Bruker BioSpin AVANCE III spectrometer</gco:CharacterString>
          </gmi:type>
          <gmi:description>
            <gco:CharacterString>PI Supplied Instrument Name: Bruker BioSpin AVANCE III spectrometer PI Supplied Instrument Description:Analyses were performed at room temperature (24.9 ± 0.1 °C) on a 400 MHz (9.4 Tesla) Bruker BioSpin AVANCE III spectrometer fitted with a double-resonance broadband inverse (BBI) probe at the College of Sciences Major Instrumentation Cluster (COSMIC) facility of Old Dominion University (Norfolk, VA). Instrument Name: Nuclear Magnetic Resonance Spectrometers Instrument Short Name:NMR   Instrument Description: Instruments that identify and quantify magnetically active chemical entities by subjecting a sample to orthogonal magnetic and electrical fields. Community Standard Description: http://vocab.nerc.ac.uk/collection/L05/current/LAB18/</gco:CharacterString>
          </gmi:description>
        </gmi:MI_Instrument>
      </gmi:instrument>
      <gmi:instrument>
        <gmi:MI_Instrument>
          <gmi:identifier>
            <gmd:MD_Identifier>
              <gmd:code>
                <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/instrument/906842.rdf" xlink:title="Shimadzu Total Organic Carbon Analyzer TOC-VCPH" xlink:actuate="onRequest">Shimadzu TOC-VCPH</gmx:Anchor>
              </gmd:code>
            </gmd:MD_Identifier>
          </gmi:identifier>
          <gmi:type>
            <gco:CharacterString>Shimadzu TOC-VCPH</gco:CharacterString>
          </gmi:type>
          <gmi:description>
            <gco:CharacterString>PI Supplied Instrument Name: Shimadzu TOC-VCPH PI Supplied Instrument Description:Dissolved organic matter was quantified as dissolved organic carbon (DOC) equivalents (in mg-C/L) on a Shimadzu TOC-VCPH instrument following standard operating procedures. Instrument Name: Shimadzu Total Organic Carbon Analyzer TOC-VCPH Instrument Short Name:TOC-VCPH   Instrument Description: The Shimadzu Total Organic Carbon Analyzer TOC-VCPH is a PC-controlled, total organic carbon analyzer (high-sensitivity model), designed to measure total carbon (TC), inorganic carbon (IC), total organic carbon (TOC), and non-purgeable organic carbon (NPOC); an optional accessory enables the measurement of particulate organic carbon (POC) and total nitrogen (TN) as well. The instrument uses the 680 degrees Celsius combustion catalytic oxidation method to analyze aqueous samples, and optionally solid and gas samples.</gco:CharacterString>
          </gmi:description>
        </gmi:MI_Instrument>
      </gmi:instrument>
      <gmi:instrument>
        <gmi:MI_Instrument>
          <gmi:identifier>
            <gmd:MD_Identifier>
              <gmd:code>
                <gmx:Anchor xlink:href="http://lod.bco-dmo.org/id/instrument/987728.rdf" xlink:title="vortex mixer" xlink:actuate="onRequest">vortex mixer</gmx:Anchor>
              </gmd:code>
            </gmd:MD_Identifier>
          </gmi:identifier>
          <gmi:type>
            <gco:CharacterString>vortex mixer</gco:CharacterString>
          </gmi:type>
          <gmi:description>
            <gco:CharacterString>PI Supplied Instrument Name: vortex mixer PI Supplied Instrument Description:Additionally, sodium 2,2,3,3-tetradeutero-3-trimethylsilylpropanoate was added (24 µL of 25 µM solution; Acros Organics, 98% D) to serve as an internal standard. Once all aliquots were added to an NMR tube, they were mixed using a vortex mixer. Instrument Name: vortex mixer Instrument Short Name:   Instrument Description: A vortex mixer is an electrical rotator that blends or mixes substances or ingredients, in whirling or rotary motion, for homogenizing samples.</gco:CharacterString>
          </gmi:description>
        </gmi:MI_Instrument>
      </gmi:instrument>
      </gmi:MI_AcquisitionInformation>
  </gmi:acquisitionInformation>
</gmi:MI_Metadata>
