| Contributors | Affiliation | Role |
|---|---|---|
| Saito, Mak A. | Woods Hole Oceanographic Institution (WHOI) | Co-Principal Investigator |
| Subhas, Adam V. | Woods Hole Oceanographic Institution (WHOI) | Co-Principal Investigator |
| McIlvin, Matthew R. | Woods Hole Oceanographic Institution (WHOI) | Scientist |
| Burdige, Emily | Woods Hole Oceanographic Institution (WHOI) | Student, Contact |
| Hayden, Matthew G. | Woods Hole Oceanographic Institution (WHOI) | Technician |
| Soenen, Karen | Woods Hole Oceanographic Institution (WHOI BCO-DMO) | BCO-DMO Data Manager |
Growth rates: "Growth rates were calculated via a linear regression of the natural log of cell counts during their exponential growth. To monitor growth, the cell densities of all cultures were measured using a flow cytometer (BD Accuri C6 Plus) and gated according to their Forward Scatter and PerCP-A (Peridinin-Chlorophyll-Protein A) concentration. At cell densities exceeding 104 cells mL-1, the aliquot taken for flow cytometry was diluted down for an accurate cell concentration measurement."
Measurements of seawater carbonate chemistry profile: "Seawater samples were taken for total alkalinity (TA, µmol kg-1) and DIC (µmol kg-1) were taken at the termination of the experiment to examine the carbonate chemistry profile of the seawater at the same time point at which samples were taken for CA activity proteomics. Samples were passed through a 0.2 μm filter (Whatman) to remove biomass and stored in 13 mL borosilicate vials where they were poisoned with mercuric chloride (0.02 % final concentration), sealed without headspace, and stored in the dark at room temperature prior to measurement. TA was measured using an open-system Gran titration on 1.5 mL samples brought to a total volume of 5 mL with Milli-Q water in technical duplicate using a Metrohm 805 Dosimat and a robotic Titrosampler (Borer et al., 2026). The precision of TA measurements assessed by the reproducibility of the standard was ± 2.5 μmol kg−1. DIC was measured on 1.5 mL samples in technical duplicate using an Apollo SciTech AS-C6L DIC analyzer equipped with a LI-COR 7815 CO2 detector (Wang et al., 2017). The precision of DIC measurements as calculated by the mean difference between technical duplicates was ± 4.2 μmol kg−1. Measurements of TA and DIC were calibrated against in-house standards using seawater collected from Vineyard Sound, which were previously calibrated against seawater-certified reference materials (Batch #205) (Dickson, 2026). Measured values of DIC and TA were used as input parameters along with T, Sal, Total P, and Total Si in CO2SYS (Lewis et al., 1998) (ver. 2.3; using constants from Mehrbach et al. (1973) refit by Dickson and Millero (1987)) to calculate pH, [HCO3-], [CO32-], [CO2]aq, and ppm CO2."
Carbonic anhydrase activity: "Carbonic anhydrase activity was assayed according to an 18O depletion method utilizing a membrane inlet mass spectrometer (MIMS), which measures concentrations of dissolved gases (Burlacot et al., 2020). A Pfeiffer QMG 220 mass spectrometer (closed-type ion source, 1–100 AMU mass range) was fitted with custom-made inlet consisting of a 6 inch long, 1/1600 O.D. stainless steel needle with 1 inch of perforations at the tip. Silastic tubing (0.23 mm thick) was gently slid over the needle to cover the perforations and was fixed by a knot at the tip of the needle. The needle functioned in tandem with the mass spec’s high vacuum (operating at 4×10−6 mbar) to pull dissolved gases from the sample or standard solution, without introduction of water, into the quadrupole mass spectrometer for detection based on their mass to charge (m/z) ratio.
The 18O depletion method tracks the ion currents of six different CO2 isotopes over time as a double-labeled spike solution (NaH13C18O3, m/z 49) interacts with a background buffer solution (described above). To prepare the spike solution, a 13C-labeled sodium bicarbonate salt (85 mg; MilliporeSigma 870081-58-1) was equilibrated in 1 mL of 18O-labeled water (≥ 97% labeled 18O; MilliporeSigma 14314-42-2) for 24 hr. For every sample, 15 µL of spike was pipetted into the 5 mL aliquot of a sample slurry solution (phosphate buffer medium (0.14 M sodium phosphate, pH 8) and resuspended cell pellet). The reaction was run in a conical reaction vial (MilliporeSigma Z115150) with a stir bar (MilliporeSigma 23227) gently agitating the solution and was held in a thermostat water jacket kept at 20°C. Utilizing the MIMS rapid response time, the interaction of the spike and the buffer are closely followed.
The addition of the spike results in an initial increase in m/z 49, which is immediately diluted by the buffer’s intense background 16O signal. The fractional abundance of 18O in 13CO2 is used to calculate a rate of equilibration. Taking the slope of the fractional abundance in log space versus time yields the rate of CO2 hydration/dehydration (Subhas et al., 2019; Uchikawa & Zeebe, 2012).
Bovine carbonic anhydrase (BCA) was used to create a calibration between known concentrations of BCA and the measured rates of CA activity. Standard curves were used to assess instrument performance but were not used to calculate an effective CA concentration for samples, as the activity of a known concentration of bovine carbonic anhydrase is incomparable to phytoplankton CAs (Krishnamurthy et al., 2008). Additionally, “blank” measurements of buffer containing no standard addition of BCA were run every analytical session. The mean plus 1σ standard deviation of all the blanks provided a conservative estimate of the variability in these measurements. This value was subtracted from the sample’s measured CA activity to achieve the blank subtracted CA activity. The data in this manuscript are reported as blank subtracted CA activity normalized to the number of cells analyzed for the respective sample, with units of reactions sec-1 cell-1."
Replicate measurements as well as calculated average and standard deviations are reported.
This section documents curation actions performed prior to publication review with the submitter, and additional information relevant to understanding and reusing this dataset. It distinguishes changes made to the submitted (meta)data from unresolved issues and/or enhancements that improve future reuse and interoperability.
CURATION ACTIONS PERFORMED ON DATA
- Split the submitted file (Ptricornutum_phsyiology_BCODMO.csv) into two tables: 1010840_v1_physiology (replicate-level data) and 1010840_v1_physiology_statistics (treatment means and standard deviations).
- Reshaped the replicate-level data from wide to long format, so replicate number is a column in 1010840_v1_physiology.
- Removed the per-replicate columns from the statistics table, since they are in the replicate-level table. The statistics table keeps only averages and standard deviations.
- Collapsed repeated whitespace in treatment names to a single space in both tables.
- Missing values are blank or “nd” in both tables.c
- Standardized column names in both tables.
CURATION ACTIONS PERFORMED ON METADATA
- BCO-DMO's standard metadata entry and text formatting steps were performed. See: https://www.bco-dmo.org/how-to/standard-curation-edits
ISSUES POTENTIALLY IMPACTING REUSE
| Parameter | Description | Units |
| Treatment_Name | experimental treatment names | unitless |
| zn2_conc | [Zn2+] in the seawater | picomolar Zn2+ (pM) |
| co2_ppm | ppm CO2 bubbled in the seawater (ambient = not bubbled) | parts per million (ppm) |
| Replicate | Replicate number (1, 2 or 3) | unitless |
| Growth_Rate | Growth rate measured for biological replicate | 1/day |
| CA_Activity | carbonic anhydrase activity measured for biological replicate | reactions per sec per cell (rxn/sec/cell) |
| DIC_Final | Final dissolved inorganic carbon concentration measured for biological replicate | micromol per kilogram seawater (umol/kg) |
| Alk_Final | Final Total Alkalinity concentration measured for biological replicate | micromol per kilogram seawater (umol/kg) |
| PH_Final | Final pH calculated for biological replicate | unitless |
| HCO3 | bicarbonate ion concentration calculated for biological replicate | micromol per kilogram seawater (umol/kg) |
| CO3 | carbonate ion concentration calculated for biological replicate | micromol per kilogram seawater (umol/kg) |
| CO2_aq | aqueous carbon dioxide concentration calculated for biological replicate | micromol per kilogram seawater (umol/kg) |
| CO2 | partial pressure of carbon dioxide calculated for biological replicate | parts per million (ppm) |
| Dataset-specific Instrument Name | Apollo SciTech AS-C6L DIC analyzer |
| Generic Instrument Name | Apollo SciTech AS-C6L Dissolved Inorganic Carbon (DIC) analyzer |
| Dataset-specific Description | Dissolved inorganic carbon was measured using an Apollo SciTech AS-C6L DIC analyzer equipped with a LI-COR 7815 CO2 detector. |
| Generic Instrument Description | An instrument designed for the analysis of dissolved inorganic carbon in samples from various aquatic environments. It comprises of a laser-based CO2 detector (LI-7815), a digital syringe pump, a mass flow controller, CO2 stripping reactor, an electronic cooling system and a computer communication assembly (RS-485, USB). The AS-C6L supersedes the earlier AS-C3 model, which used non-dispersive infra-red CO2 detection (LI-7000, discontinued). The AS-C6L improves on the AS-C3 by incorporating a multi-sampler of one set of standards plus 8 samples, and uses improved Apollo SciTech software. The AS-C6L is suitable for use in either shipboard or land-based laboratories. It maintains a precision of +/-0.1 % for seawater (or +/-2 umol/kg), enables sample volumes ranging from 0.5 - 3.5 ml per analysis, and an analytical rate of approximately 3 minutes. |
| Dataset-specific Instrument Name | BD Accuri C6 Plus |
| Generic Instrument Name | BD Biosciences Accuri C6 Plus flow cytometer |
| Dataset-specific Description | Cell counts were measured using a BD Accuri C6 Plus. Samples were analyzed in a 96-well plate. An average cell count between two technical replicates was reported for each sample. The instrument was calibrated using the BD CS&T RUO beads with a known median fluorescence intensity (MFI) and distribution (rCV) to monitor performance. |
| Generic Instrument Description | A flow cytometer designed to detect fluorochromes (including FITC, PE, APC), polymer dyes, and fluorescent proteins (including GFP, YFP, mCherry). The instrument is equipped with a blue and red laser, two light scatter detectors, and four fluorescence detectors with user-interchangeable filters. A non-pressurised peristaltic pump system drives the fluidics. The system monitors the sample volume pulled per run and can calculate absolute counts or sample concentration per microliter (uL). In the standard configuration (3-blue/1-red), three detectors read fluorescence emissions from fluorochromes excited by the blue laser, while a fourth detector reads emissions from fluorochromes excited by the red laser. The optional Selectable Laser Module allows the system to operate in 2-blue/2-red and 4-blue configurations. The minimum detectable particle size and sample volume are 0.5 micrometers (um) and 0.5 uL respectively. The maximum number of events is 1 million with an acquisition rate of up to 10,000 events/second. |
| Dataset-specific Instrument Name | Pfeiffer QMG 220 mass spectrometer |
| Generic Instrument Name | Membrane Inlet Mass Spectrometer |
| Dataset-specific Description | Carbonic anhydrase activity measurements were made with a membrane inlet mass spectrometer, which uses a quadrupole mass spectrometer for detection based on ions mass to charge (m/z) ratio. |
| Generic Instrument Description | Membrane-introduction mass spectrometry (MIMS) is a method of introducing analytes into the mass spectrometer's vacuum chamber via a semipermeable membrane. |
| Dataset-specific Instrument Name | Metrohm 805 Dosimat and a robotic Titrosampler |
| Generic Instrument Name | Metrohm 805 Dosimat |
| Dataset-specific Description | Total alkalinity was measured using a Metrohm 805 Dosimat and a robotic Titrosampler. A pH calibration was run prior to any analytical session in order to assess electrode sensitivity. The slope of this calibration needed to be > 95% to ensure accurate data reporting. |
| Generic Instrument Description | The Metrohm 805 Dosimat is a dispensing instrument for titrating and dosing operations in the laboratory. The 805 Dosimat is controlled by Touch control or PC control software. The instrument controls the dosing of liquids, which are attached via an exchange unit. Metrohm recommends using the Metrohm 806 Exchange units which come with 1, 5, 10, 20, or 50 milliliter (mL) dosing cylinders. The instrument can read and overwrite data from the exchange unit. It has a resolution of 20,000 steps per cylinder volume and a dosing/filling time of 18 seconds.
The 805 Dosimat and the corresponding 806 Exchange Unit are suitable as a buret not only for simply dosing auxiliary solutions but also for titrations. Additional information is available from the instrument manufacturer: https://www.metrohm.com/en_au/products/2/8050/28050010.html |
Although carbon dioxide (CO2) is found both in the atmosphere and in sea water, it does not react quickly with water. This presents a problem for marine organisms that need to wait for CO2 to react with water before using it for photosynthesis. Therefore, organisms use an enzyme to greatly speed up this reaction. The enzyme, known as carbonic anhydrase (CA), is so useful that it is found across the entire tree of life. However, the role of carbonic anhydrase in the CO2 cycle has been hard to measure. In this project, a team of investigators from the Woods Hole Oceanographic Institution will use a combination of instrument techniques and laboratory experiments to investigate the role of different types of CA in marine organisms. The team will identify the different types of CA and their inherent catalytic rates. The team will then identify the metal cofactors present in these enzymes, which are key for enzyme function. This work will deepen our understanding of the biochemical basis for carbon dioxide cycling in marine phytoplankton, and will provide key insights into one of the most ubiquitous and fastest enzymes on the planet. The team will collaborate with Professor Indu Sharma and her students from Hampton University which has just launched a new marine science major program. Team members will visit Hampton University for a workshop on careers in oceanography. In Year 2, Professor Sharma and her students will accompany the team on a research expedition to the Bermuda-Atlantic Time Series and will help design a sampling campaign focused on the shared research interests of Professor Sharma and the investigators.
Carbonic anhydrases (CAs) are ubiquitous enzymes involved in almost every carbon transformation in the marine environment. Every CA uses a metal cofactor in its active site, and the expression of CAs is tied to the uptake and utilization of trace metals such as zinc and cobalt in the surface ocean. We are starting to understand that organisms express many different forms of CA, all of which serve distinct physiological roles; exhibit unique catalytic rates; and can use different metal cofactors at the enzyme active site. In this proposal, the team will exploit this enzymatic diversity to investigate carbonic anhydrase kinetics in marine diatoms. By combining an isotope-based enzyme activity assay with quantitative proteomics, they will document the inherent kinetics of multiple CA isoforms. In addition, they will identify the metal cofactors associated with the most abundant CAs, therefore providing a direct linkage between enzyme activity and trace metal utilization.
This award reflects NSF's statutory mission and has been deemed worthy of support through evaluation using the Foundation's intellectual merit and broader impacts review criteria.
| Funding Source | Award |
|---|---|
| NSF Division of Ocean Sciences (NSF OCE) |