<div><p>A multi-sensor data sonde (MS5; Hydrolab, USA) was mounted at the same height as the ADV measuring volume (0.30 m) and monitored the O2, pH, temperature, and salinity of the water column. The data sonde pH sensor and the H+ ISFET sensor were calibrated, pre- and post-deployment, using NIST-traceable pH buffers. These calibrations provided the slope (mV per pH unit) for the sensors and the data sonde, which was then temperature and salinity corrected using in situ data. The data sonde pH was primarily used as a check on the calibration of the ISFET sensor.</p></div>
O2, pH, temperature, and salinity in the water column
<div><p>This dataset includes O2, pH, temperature, salinity, chlorophyll and turbidity data from a data sonde located within the water column near eddy covariance instrument</p>
<p><strong>Related Reference:</strong></p>
<p>Long MH, Charette MA, Martin WR, McCorkle DC. (2015) Oxygen metabolism and pH in coastal ecosystems: Eddy Covariance Hydrogen ion and Oxygen Exchange System (ECHOES). Limnology and Oceanography: Methods. DOI: 10.1002/lom3.10038</p>
<p><strong>Related Datasets:</strong></p>
<p><a href="http://www.bco-dmo.org/dataset/563439" target="_blank">Datasonde in a light chamber</a><br /><a href="http://www.bco-dmo.org/dataset/568429" target="_blank">Eddy covariance proton and oxygen flux data</a></p></div>
Datasonde in water column
<div><p>MATLAB code was developed to calculate the EC fluxes. Several data treatment procedures were tested; most of them were adapted from commonly used calculation procedures for terrestrial eddy covariance measurements (e.g. Baldocchi et al. 2003). The flux was determined over periods of 0.25 h. Data were averaged to 8Hz for flux calculations due to the ~ 10 Hz sample output refresh rate of the O<sub>2</sub> optode meter. The fluctuating components of the vertical velocity, O<sub>2</sub> and H<sup>+</sup> (Eq. 1), were determined by Reynolds decomposition with the means determined by a running average window of 5 minutes, which was identified to be the optimal time period for maintaining a constant flux signal while removing non-turbulent fluctuations (McGinnis et al. 2008).</p>
<p>Inherent in the high-frequency ADV velocity data were anomalous spikes that contaminated the EC signal. These velocity data spikes were replaced with interpolated data using existing MATLAB de-spiking procedures described by Goring and Nikora (2002) that resulted in the interpolation of <1 % of the vertical velocities used to calculate the flux. The ECHOES H<sup>+</sup> and O<sub>2</sub> signals were compared to the water column data sonde measurements to verify that the sensors had not malfunctioned by confirming that the real-time correlation between sensors and data sonde matched that of the overall correlation (i.e. the calibration curves). All signals were then examined manually to remove any further data spikes that were due to malfunction, fouling, or debris contacting the sensors. A GoPro camera (HERO2, GoPro, USA) on the ECHOES frame helped identify fouling of the sensors. Due to the difficulty of accurately leveling the instrument in the field, and the resulting potential to bias the vertical velocity measurements, a planar rotation was used based on the methods described by Lorke et al. (2013) that uses an average rotation angle for the different current directions.</p>
<p>The benthic chamber fluxes were calculated from the change in O<sub>2</sub>, H<sup>+</sup>, DIC and TA concentrations in the chambers through time, using the known volume and sediment surface area of the chamber. Corrections for the removal of water for DIC and TA samples were included to account for the influx of ambient water, utilizing the measured water column conditions.</p>
<p><strong>BCO-DMO Processing:</strong></p>
<p>- added conventional header with dataset name, PI name, version date, reference information<br />
- renamed parameters to BCO-DMO standard<br />
- reformatted date</p></div>
563656
Datasonde in water column
2015-07-31T08:45:49-04:00
2015-07-31T08:45:49-04:00
2023-07-07T16:10:26-04:00
urn:bcodmo:dataset:563656
Data describing O2, pH, temperature, and salinity from a data sonde located within the water column near an eddy covariance instrument (ECHOES project)
false
Long, M. H., Charette, M. A., McCorkle, D. C., Martin, W. (2015) Data describing O2, pH, temperature, and salinity from a data sonde located within the water column near an eddy covariance instrument (ECHOES project). Biological and Chemical Oceanography Data Management Office (BCO-DMO). (Version 2015-06-09) Version Date 2015-06-09 [if applicable, indicate subset used]. http://lod.bco-dmo.org/id/dataset/563656 [access date]
true
2015-06-09
false
2015-06-09
HTML
https://www.bco-dmo.org/dataset/563656
text/html
Datapackage.json
Frictionless Data Package
https://www.bco-dmo.org/dataset/563656/datapackage.json
application/vnd.datapackage+json
PDF
https://www.bco-dmo.org/dataset/563656/Dataset_description.pdf
application/pdf
JSON-LD
https://www.bco-dmo.org/dataset/563656.json
application/ld+json
Turtle
https://www.bco-dmo.org/dataset/563656.ttl
text/turtle
RDF/XML
https://www.bco-dmo.org/dataset/563656.rdf
application/rdf+xml
ISO 19115-2 (NOAA Profile)
https://www.bco-dmo.org/dataset/563656/iso
application/xml
http://www.isotc211.org/2005/gmd-noaa
Dublin Core
https://www.bco-dmo.org/dataset/563656/dublin-core
application/xml
http://purl.org/dc/elements/1.1/
563656
http://lod.bco-dmo.org/id/dataset/563656