http://lod.bco-dmo.org/id/dataset/767391
eng; USA
utf8
dataset
Highest level of data collection, from a common set of sensors or instrumentation, usually within the same research project
Biological and Chemical Oceanography Data Management Office (BCO-DMO)
Unavailable
508-289-2009
WHOI MS#36
Woods Hole
MA
02543
USA
info@bco-dmo.org
http://www.bco-dmo.org
Monday - Friday 8:00am - 5:00pm
For questions regarding this resource, please contact BCO-DMO via the email address provided.
pointOfContact
2019-05-13
ISO 19115-2 Geographic Information - Metadata - Part 2: Extensions for Imagery and Gridded Data
ISO 19115-2:2009(E)
Biological, chemical, and physical water quality indicators of the Neuse River, North Carolina from 2008 through 2013
2019-05-13
publication
2019-05-13
revision
Marine Biological Laboratory/Woods Hole Oceanographic Institution Library (MBLWHOI DLA)
2019-05-15
publication
https://doi.org/10.1575/1912/bco-dmo.767391.1
Hans Paerl
University of North Carolina at Chapel Hill
principalInvestigator
Biological and Chemical Oceanography Data Management Office (BCO-DMO)
Unavailable
508-289-2009
WHOI MS#36
Woods Hole
MA
02543
USA
info@bco-dmo.org
http://www.bco-dmo.org
Monday - Friday 8:00am - 5:00pm
For questions regarding this resource, please contact BCO-DMO via the email address provided.
publisher
Cite this dataset as: Paerl, H. (2019) Biological, chemical, and physical water quality indicators of the Neuse River, North Carolina from 2008 through 2013. Biological and Chemical Oceanography Data Management Office (BCO-DMO). (Version 1) Version Date 2019-05-13 [if applicable, indicate subset used]. doi:10.1575/1912/bco-dmo.767391.1 [access date]
Biological, chemical, and physical water quality indicators of the Neuse River. Dataset Description: <p>The Neuse River Estuary Water Quality Dataset is a compilation of the biological, chemical and physical water quality data that was collected along the length of the Neuse River Estuary, NC from March 14, 1985 to February 15, 1989 and from January 24, 1994 to the present.&nbsp; The primary purpose of this dataset was to provide long-term environmental information to supplement experimental, process-based research, including the Atlantic Coast Environmental Indicators Consortium (ACE-INC) project as well as other laboratory studies.&nbsp;&nbsp;</p>
<p>The full YSI profile data related to this dataset can be found at&nbsp;Neuse River Estuary YSI Profile:&nbsp;<a href="https://www.bco-dmo.org/dataset/767641">https://www.bco-dmo.org/dataset/767641</a>.</p> Methods and Sampling: <p>Bi-weekly water sampling and in situ measurements were performed at fixed sampling stations.&nbsp; Water samples and in situ measurements were collected at the surface (approximately 0.2 meters) and at the bottom of the water column (approximately 0.5 meters from the sediment layer).&nbsp; These data are included in the worksheet titled "NRE Dataset."&nbsp; In situ measurements were also performed throughout the water column in 0.5 meter depth increments.&nbsp; These data are included in the worksheet titled "NRE YSI Profiles."&nbsp; Parameters measured include: temperature, salinity, specific conductivity, dissolved oxygen (DO), pH, chlorophyll fluorescence, photosynthetically active radiation (PAR), turbidity, barometric pressure, secchi depth, colored dissolved organic matter (CDOM), particulate organic carbon (POC) and nitrogen (PN), dissolved organic and inorganic carbon, dissolved inorganic nutrient concentrations (nitrate/nitrite, ammonium, total dissolved nitrogen, phosphate and silicic acid), chlorophyll a, primary productivity and diagnostic phytoplankton pigment concentrations (chlorophylls and carotenoids).&nbsp; Calculated parameters include:&nbsp; diffuse light attenuation coefficient (Kd), carbon to nitrogen molar ratio (C:N), dissolved inorganic nitrogen (DIN; nitrate/nitrite plus ammonium), dissolved organic nitrogen (DON; total dissolved nitrogen minus dissolved inroganic nitrogen) and the nitrogen to phosporus molar ratio (N:P).&nbsp;&nbsp;</p>
<p>Methods<br />
Water sampling was conducted bi-weekly. When collection was split over two days, a single date was used based on the upstream or majority stations.</p>
<p>Stations were selected to cover the entire length of the Neuse River Estuary from Streets Ferry Bridge (Station 0) to the mouth of the estuary where it flows into Pamlico Sound.&nbsp; When possible, efforts were made to select locations with key stationary features (channel markers, buoys and land markers) to allow easy station identification in the field.<br />
<br />
Surface water samples were collected by submerging 10 liter high-density polyethylene containers just below the water surface or by filling the containers with surface water collected from bucket casts.&nbsp; Bottom water samples were collected with a horizontal plastic Van Dorn sampler. Starting December 2007, all samples collected with diaphragm pump and a weighted, marked hose. All containers were kept in dark coolers at ambient temperature during transport to the laboratory.&nbsp; All filtration was done within a few hours of collection and when conditions permitted, on board the research vessel.<br />
<br />
Prior to the 09/13/2000 sampling date, in situ measurements were performed at discrete depths using a Hydrolab Data Sonde 3 equipped with a multiprobe and SVR3 display logger.&nbsp; Beginning on the 09/13/2000 sampling date, in situ measurements were performed at discrete depths on the sunlit side of the research vessel using a Yellow Springs Instruments (YSI Incoporated, Ohio) multiparameter sonde (Model 6600 or 6600 EDS-S Extended Deployment System) equipped with a YSI conductivity/temperature probe (Model 6560), a YSI chlorophyll probe (Model 6025), a YSI pH probe (Model 6561 or 6566), a YSI pulsed dissolved oxygen probe (Model 6562), a self cleaning YSI turbidity probe (Model 6026 or 6136), and beginning on the 07/30/2003 sampling date, a flat Li-Cor sensor (UWQ-PAR 6067).&nbsp; The YSI sonde was coupled to a either a YSI 610 DM datalogger or a YSI 650 MDS Multi-parameter Display System datalogger.&nbsp; In situ measurements were performed at the surface (approximately 0.2 meters) and at the bottom of the water column (approximately 0.5 meters from the sediment layer).&nbsp; These data are included in the worksheet titled "NRE Dataset."&nbsp; In situ measurements were also performed throughout the water column in 0.5 meter depth increments.&nbsp; These data are included in the worksheet titled "NRE YSI Profiles."&nbsp; The data were stored on the datalogger and downloaded to Ecowin software upon return to the laboratory.</p>
<p>The secchi disk was deployed off of the sunlit side of the research vessel.&nbsp; The depth (in meters) at which the secchi disk was no longer visible by the naked eye was recorded as the secchi depth.<br />
<br />
The diffuse light attenuation coefficient, Kd, was calculated from depth profiles of photosynthetically active radiation (PAR, 400-700 nm).&nbsp; Prior to the 07/30/2003 sampling date, PAR measurements were performed with a spherical underwater quantum sensor (LI-COR LI-193SA) coupled to a LI-COR LI-1000 datalogger.&nbsp; Beginning on the 07/30/2003 sampling date, a flat underwater quantum sensor (LI-COR LI-193SA) attached to a Yellow Springs Instruments YSI 6600 or YSI 6600 EDS-S sonde was used to measure PAR.&nbsp; Measurements of PAR were performed on the sunlit side of the research vessel in 0.5 meter depth increments, beginning just below the water surface.&nbsp; The diffuse attenuation coefficient is the slope of the linear regression between natural log transformed PAR data and depth.&nbsp;<br />
<br />
Colored dissolved organic matter (CDOM) was measured using a Turner Designs TD-700 fluorometer configured with a near-UV mercury vapour lamp, a 350 nm excitation filter, and a 410–600 nm emission filter. The fluorometer was calibrated to quinine sulfate (QS) solutions made up in 2 N sulfuric acid. Water samples were vacuum filtered (less than 25 kilopascal) using pre-combusted Whatman glass microfibre filters (GF/F) and the filtrate was stored in scintillation vials in the dark at 4 degrees Celsius until fluorometric analysis.&nbsp; The official decision (3/2/2017) is that cdom results from 12/1/2003 through 4/25/2011 would be multiplied by a corrective factor of 2.0.&nbsp; Results for sample date of 5/9/2011 and after do not need correcting.&nbsp; It is believed the stock solution was made wrong, making a 1L recipe for 600 ug/L in a 500 ml flask equals 1200 ug/L stock solution.&nbsp; Standards were still calibrated according to recipe, but were actually 2x as strong.&nbsp;<br />
<br />
&nbsp;The official decision (3/2/2017) is that cdom results from 12/1/2003 through 4/25/2011 would be multiplied by a corrective factor of 2.0.&nbsp; Results for sample date of 5/9/2011 and after do not need correcting.&nbsp; It is believed the stock solution was made wrong, making a 1L recipe for 600 ug/L in a 500 ml flask equals 1200 ug/L stock solution.&nbsp; Standards were still calibrated according to recipe, but were actually 2x as strong.&nbsp;<br />
<br />
Particulate organic carbon (POC) concentrations were determined by elemental analysis of material collected on pre-combusted Whatman GF/F glass fiber filters.&nbsp; Carbonates were removed from the filters by vapor phase acidification using concentrated hydrochloric acid (HCl).&nbsp; After drying at 60 0C, the filters were rolled in tin disks and injected into a PE 2400 Series II CHNS/O Analyzer calibrated with acetanilide ending in June 2014.&nbsp; Starting on the Neuse River sample date of June 2, 2014, a Costech Analytical Technologies, Inc. Elemental Combustion System CHNS-O ECS 4010 was used for elemental analysis by "flash combustion/chromatographic separation and multi-detector techniques".&nbsp; The Costech Instrument utilizes EAS Clarity Software.&nbsp; Atropine standards are used to develop a calibration curve (C 70.56%, N 4.84%, and carbon response ratio of 0.025 +/-0.003).&nbsp; NIST Buffalo River Sediment Reference Material 8704 (C 3.351% +/-0.017, N 0.20% +/-0.04) and/or Acetanilide Bypass (C 71.09%, N 10.36%, carbon response ratio of 0.055 +/- 0.003) may used for calibration or a check standard.</p>
<p>The molar ratio of particulate organic carbon (POC) to particulate nitrogen (PN), or C:N, was calculated by dividing POC by PN.&nbsp; (Carbon ug/L /12.011)/(Nitrogen ug/L/14.007).<br />
<br />
Dissolved organic carbon (DOC) concentration was measured using a Shimadzu TOC-5000A Analyzer:&nbsp; Water samples were vacuum filtered (less than 25 kilopascal) using pre-combusted Whatman glass microfibre filters (GF/F).&nbsp; The filtrate was stored in pre-combusted glass scintillation vials with Teflon closures and frozen at -20 degrees Celsius until analysis.&nbsp; The Shimadzu TOC-5000A Analyzer uses high temperature catalytic oxidation followed by non-dispersive infrared analysis of the CO2 produced.&nbsp; Samples were acidified to a pH less than 2 and sparged with air before they were analyzed for non-volatile organic carbon.&nbsp; DOC values in 1996 were run from previously run nutrient samples. Starting February 2018, all stations were collected.&nbsp; Prior to Feb. 2018 only NR 0, 30, 70, 100, 120, and 160 surface and bottom stations were measured.<br />
<br />
Nitrate/nitrite (NO3- / NO2-) concentration was determined using a Lachat/Zellweger Analytics QuikChem 8000 flow injection autoanalyzer (Milwaukee, WI, USA) using method FIA 31-107-04-1-C:&nbsp; Water samples were vacuum filtered (less than 25 kiloPascals) using pre-combusted Whatman glass microfibre filters (GF/F).&nbsp; The filtrate was stored in high-density polyethylene bottles and frozen at -20 degrees Celsius until analysis.&nbsp; Two replicates were run from the same bottle.&nbsp; Method detection limits (MDL, µg L-1) were: before 4Nov02 = 1.06; beginning 4Nov02 = 3.68; beginning 11Jul06 = 0.6; beginning 1Dec09 = 0.27; beginning 13Feb12 = 0.36; beginning 18Feb15 = 0.71.&nbsp; MDL was changed to 0.88 on a sample date of 8/21/2017.<br />
<br />
Ammonium (NH4+) concentration was determined using a Lachat/Zellweger Analytics QuikChem 8000 flow injection autoanalyzer (Milwaukee, WI) using method FIA 31-107-06-1-A/B:&nbsp; Water samples were vacuum filtered (less than 25 kiloPascals) using pre-combusted Whatman glass microfibre filters (GF/F).&nbsp; The filtrate was stored in high-density polyethylene bottles and frozen (-20 degrees Celsius) until analysis.&nbsp; Two replicates were run from the same bottle.&nbsp; &nbsp;Method detection limits (MDL, µg L-1) were: before 4Nov02 = 4.69; beginning 4Nov02 = 4.31; beginning 11Jul06 = 2.55; beginning 1Dec09 = 3.98; beginning 13Feb12 = 2.87; beginning 18Feb15 = 3.34.&nbsp; MDL was changed to 1.05 on sample date 8/21/2017.<br />
<br />
Dissolved inorganic nitrogen (DIN) concentration was calculated by summing nitrate/nitrite (NO3- / NO2-) and ammonium (NH4+).&nbsp; If either NO3- / NO2- or NH4+ were below the detection limit (-9999), they were taken to be zero for this calculation.<br />
<br />
Total dissolved nitrogen (TDN) was measured by in-line digestion using the Lachat/Zellweger Analytics QuikChem 8000 flow injection autoanalyzer (Milwaukee, WI, USA) using method FIA 31-107-04-3-B for low total nitrogen for brackish/fresh waters (detection level: 0.1 - 5.0 milligrams nitrogen per liter):&nbsp; Water samples were vacuum filtered (less than 25 kiloPascals) using pre-combusted Whatman glass microfibre filters (GF/F).&nbsp; The filtrate was stored in high-density polyethylene bottles and frozen at -20 degrees Celsius until analysis.&nbsp; Two replicates were run from the same bottle.&nbsp; Total dissolved nitrogen by in-line digestion works by oxidizing all the nitrogen compounds to nitrate by heating to 100 degrees Celsius and adding energy via UV light.&nbsp; The pH is dropped from 9.1 to 3 during the decomposition.&nbsp; The entire digestion occurs prior to the injection valve.&nbsp; The nitrate/nitrite concentration is then determined using standard colorimetric techniques similar to the strict nitrate/nitrite manifold. Method detection limits (MDL, µg L-1) were: beginning 1Nov04 = 78; beginning 11Jul06 = 35.4 beginning 1Dec09 = 25.6; beginning 13Feb12 = 36.9; beginning 14Jan13 = 19.6; beginning 18Feb15 = 10.5.&nbsp; MDL changed to 7.30 on sample date of 8/21/2017&nbsp;<br />
<br />
Dissolved organic nitrogen (DON) was calculated by subtracting dissolved inorganic nitrogen (DIN) from total dissolved nitrogen (TDN).&nbsp; If the DIN value used in the calculation was below the detection limit, it was taken to be zero for this calculation.&nbsp; At one point DON was determined by high temperature oxidation using the Antek 7000N or Antek 7000V analyzer.<br />
<br />
Orthophosphate (PO43-) was determined using a Lachat/Zellweger Analytics QuikChem 8000 flow injection autoanalyzer (Milwaukee, WI) using method FIA 31-115-01-1-F/G:&nbsp; Water samples were vacuum filtered (less than 25 kiloPascals) using pre-combusted Whatman glass microfibre filters (GF/F).&nbsp; The filtrate was stored in high-density polyethylene bottles and frozen at -20 degrees Celsius until analysis.&nbsp; Two replicates were run from the same bottle.&nbsp; Method detection limits (MDL, µg L-1) were: before 4Nov02 = 0.35; beginning 4Nov02 = 0.74; beginning 1Nov04 = 1.68; beginning 11Jul06 = 1.84; beginning 1Dec09 = 0.62; beginning 13Feb12 = 0.69; beginning 18Feb15 = 0.61.&nbsp; MDL was changed to 1.80 on the sample date of 8/21/2017.<br />
<br />
The molar ratio of nitrogen (N) to phosphorus (P), or N:P, was calculated by dividing dissolved inorganic nitrogen (DIN) by orthophosphate (PO43-) concentrations.<br />
<br />
Silicic acid (SiO2) was measured after vacuum filtration (&lt; 25 kPA) of the collected water samples through pre-combusted (3-4 hours at 450 0C) Whatman GF/F glass fiber filters.&nbsp; The filtrate was stored in high-density polyethylene bottles and frozen (-20 0C) until analysis.&nbsp; Two replicates were run from the same sample bottle.&nbsp; Nitrate plus nitrite concentrations were determined using a Lachat QuikChem 8000 flow injection autoanalyzer (Milwaukee, WI, USA).&nbsp; Method detection limits (MDL, µM) were: before 4Nov02 = 0.18; beginning 4Nov02 =1.24; beginning 1Nov04 = 1.86; beginning 11Jul06 = 0.75; beginning 1Dec09 = 0.75; beginning 13Feb12 = 0.09; beginning 18Feb15 = 0.08.&nbsp; MDL was changed to 0.03 on sample date of 8/21/2017.<br />
<br />
Chlorophyll a (Chl a) measurements prior to the 08/17/1999 sampling date were measured on a Shimadzu UV-160U spectrophotometer using the trichromatic equation following sonication (45-60 s) and overnight extraction of glass fiber filters in 90 % acetone.&nbsp; Beginning on the 08/17/1999 sampling date, Chl a concentration was measured using the modified in vitro fluorescence technique in EPA Method 445.0 (Welshmeyer 1994, Arar et al.&nbsp; 1997): Fifty milliliters of each water sample was vacuum filtered (less than 25 kilopascals) in duplicate at low ambient light conditions using 25 mm Whatman glass microfibre filters (GF/F).&nbsp; The filters were blotted dry, wrapped in foil and frozen immediately at -20 degrees Celsius until analysis.&nbsp; Chlorophyll a was extracted from the filter using a tissue grinder and 10 mL of 90 percent reagent grade aqueous acetone (v/v with deionized water, Fisher Scientific NF/FCC Grade). The samples remained in the acetone overnight at -20 degrees Celsius.&nbsp; The extracts were filter-clarified using a centrifuge and analyzed on a Turner Designs TD-700 fluorometer that was configured for the non-acidification method of Welschmeyer (1994).&nbsp; The value reported is the average chlorophyll a concentration measured from the two filters.&nbsp; The fluorometer was calibrated with a known concentration of pure Chl a that was determined using a Shimadzu UV-160U spectrophotometer and the extinction coefficients of Jeffrey and Humphrey (1975).&nbsp; The calibration was checked daily against a solid secondary standard (Turner Designs, proprietary formula).&nbsp; As of August 2010, fluorescence was also measured on a TurnerDesigns Trilogy fluorometer.&nbsp; References: 1.&nbsp; Welschmeyer, N.A. 1994. Fluorometric analysis of chlorophyll a in the presence of chlorophyll b and pheopigments. Limnol. Oceanogr. 39:1985-1992.&nbsp; 2.&nbsp; Arar, E.J., W.L. Budde, and T.D. Behymer.&nbsp; 1997.&nbsp; Methods for the determination of chemical substances in marine and environmental matrices.&nbsp; EPA/600/R-97/072.&nbsp; National Exposure Research Laboratory, U.S. Environmental Protection Agency, Cincinnati, Ohio.&nbsp; 3. Jeffrey, S.W., R.F.C. Mantoura, and S.W. Wright.&nbsp; 1997.&nbsp; Phytoplankton pigments in oceanography:&nbsp; Guidelines to modern methods.&nbsp; UNESCO Publishing, Paris, France.</p>
<p>Spec was used to determine chla up until AUGUST 1999.&nbsp; The spec results before Aug 1999 are corrected to correspond to the change in analysis with the Turner Designs fluorometer.&nbsp; Figure 1 presents raw and log transformed regressions between the HPLC and SPEC determinations of chl a in the Neuse during calendar year 1998.&nbsp; It appears that the SPEC method produces chl a values that are roughly 15 per cent higher than the HPLC method.&nbsp; Figure 2 presents similar regressions between HPLC and FLUO determinations of chl a in the Neuse from August – December of 1999.&nbsp; It appears that the FLUO method produces chl a values that are roughly 67 per cent higher than the HPLC method.&nbsp; These figures suggest two important problems for utilizing existing chl a data in water quality modeling in the Neuse; (i) a decision must be made which analysis technique will be accepted as the standard for determining chl a, and (ii) a correction must be applied to equilibrate IMS chl a values determined by the SPEC and FLUO methods.<br />
<br />
Primary Productivity rate was measured using an adaptation of Steeman Nielsen's (1952) 14C bicarbonate method (Paerl et al. 1998).&nbsp; This method of measuring primary productivity allows direct measurement of carbon uptake and measures only net photosynthesis:&nbsp; Water samples were stored in 10 Liter high density polyethylene containers overnight in the research pond, a flow through system that receives water from the adjacent Bogue Sound, thereby simulating ambient water temperatures.&nbsp; The following morning the water samples were removed from the pond and transported to the laboratory for analysis.&nbsp; Water samples (76 milliliters) were added to three clear plastic square bottles to determine light uptake of carbon in triplicate and to 1 dark bottle to determine dark uptake of carbon.&nbsp; A solution of radioactive carbonate (300 microliters) was added to each bottle.&nbsp; The bottles were incubated for 4 hours in the pond.&nbsp; The light bottles were incubated underneath a field light simulator, while the dark bottles were incubated in a covered perforated bucket that was submerged in the pond.&nbsp; The FLS was used to simulate the ambient light conditions that phytoplankton are exposed to in the estuary (mixing conditions).&nbsp; The FLS is comprised of a rotating wheel with varying levels of screening.&nbsp; During the incubation period, photosynthetically active radiation (PAR) measurements were performed using a 2 pi Li-Cor LI-192SA spherical quantum sensor attached to a Li-Cor data logger.&nbsp; After the incubation period, the samples were returned to the laboratory, shaken and the entire contents were gently vacuum filtered (less than 25 kilopascals) using 25 mm Whatman glass microfibre filters (GF/F).&nbsp; The filters were placed in wooden drying trays and treated with concentrated hydrochloric acid fumes for 40 minutes to an hour to remove inorganic 14C.&nbsp; The filters were folded in half and placed in 7 milliliter plastic scintillation vials.&nbsp; Five milliliters of liquid scintillation cocktail (ecolume or cytoscint) was added to the vials.&nbsp; The vials were capped, shaken, stored in the dark for 3-24 hours and then assayed for radioactivity using a Beckman liquid scintillation counter.&nbsp; In addition to the samples, triplicate voucher samples were used to quantify the radioactivity of the 14C added.&nbsp; Voucher samples consisted of 100 microliter of 14C and 100 microliters of phenylethylamine.&nbsp; These vials also received 5 milliliters of liquid scintillation cocktail.&nbsp; A background vial and two 14C background standards were used.&nbsp; &nbsp;The quantity of carbon fixed is proportional to the fraction of radioactive carbon assimilated.&nbsp; (Paerl, H.W., J.L. Pinckney, J.M. Fear, and B.L. Peierls 1998. Ecosystem responses to internal and watershed organic matter loading: consequences for hypoxia in the eutrophying Neuse River Estuary, North Carolina, USA. Marine Ecology Progress Series 166: 17-25; Steemann Nielsen, E. 1952. The use of radio-active carbon (C14) for measuring organic production in the sea. Journal du Conseil permanent international pour L'Exploration de la Mer 18: 117-140)<br />
<br />
Diagnostic phytoplankton photopigments were identified, separated and quantified by high performance liquid chromatography coupled to an in-line photodiode array spectrophotometer (Jeffrey et al.&nbsp; 1997):&nbsp; Known volumes of water sample (500-1000 milliliters, enough to obtain color on the filter) were vacuum filtered (less than 25 kiloPascals) through 25 or 47 millimeter Whatman glass microfibre filters (GF/F) under reduced light conditions.&nbsp; The filters were blotted dry, folded in half, wrapped in foil and then immediately frozen at -20 degrees Celsius until analysis.&nbsp; The filters were placed in 15 milliliter centrifuge tubes containing 1.5-3.0 milliliters of 100% acetone (HPLC Grade), sonicated for 30-60 seconds using a Fisher Sonic Dismembrator 300 with microtip and extracted at -20 degrees Celsius for 12-24 hours.&nbsp; After extraction the samples were centrifuged at 4500 rpm and the supernatant (i.e.- the combined extracted pigments) collected &amp; filtered into amber glass autosampler vials using Millipex Millipore 0.45 micometer PTFE.&nbsp; Two hundred microliters of extractant from each vial was injected into the HPLC system using a Spectra Physics (now Thermo Separations Products) AS3000 autosampler and SP8800 pump, running a non-linear, 55 minute, 2-solvent gradient adapted from Van Heukelem et.al. 1994 or 1995?.&nbsp; The nonlinear, variable flow, binary gradient consisted of solvent A [80% methanol : 20% ammonium acetate (0.5 M adjusted to pH 7.2)] and B (80% methanol : 20% acetone).&nbsp; The extractant was separated into individual pigments using a series of C18 reverse-phase columns to optimize photopigment separations:&nbsp; The column order was a Rainin Microsorb guard column (0.46 x 1.5 centimeters, 3 micrometer packing) followed by a single monomeric reverse-phase C18 column (Rainin Microsorb-MV, 0.46 x 10 cm, 3 µm packing) followed by two polymeric reverse-phase C18 columns (Vydac 201TP5, 0.46 x 25 cm, 5 µm packing).&nbsp; The columns were kept at a constant 52 degrees Celsius in an Alltech 330 column heater.&nbsp; The separated pigments were then passed through an in line Shimadzu SPD-M10AV photodiode array detector which measured the absorbance of the sample/extractant, scanning the range of 350-800 nanometers every 2 seconds.&nbsp; The data was collected and analyzed using Shimadzu's EZChrom software.&nbsp; Individual pigments are identified using a combination of peak retention time and absorbance spectrum shape.&nbsp; Retention times and absorbance spectra are identified for each pigment by analyzing known pigments (either as pure standards or pigments or isolated from algal cultures).&nbsp; Pigments are quantified from their peak areas, calculated at 440nm. A calibration curve is generated by injecting various volumes of a mixed standard composed of known quantities of seven pure pigment standards (fucoxanthin, zeaxanthin, bacteriochlorophyll a, canthaxathin, chlorophyll b, chlorophyll a, echinenone and ß-carotene) and calculating the peak areas of those pigments&nbsp; &nbsp;The peak areas are regressed against the known quantities of each pigment to calculate the slope (Response Factor) for that pigment.&nbsp; Response factors for pigments we do not have reference standards for are calculated using the ratio of absorbance coefficients of each pigment to its closest structurally related reference pigment, multiplying the known pigment's response factor by that ratio. Pigments extracted from the samples are then quantified by multiplying the peak areas of a chromatogram at 440nm by the response factors. Pigment values listed as below detection were below the software threshold for peak detection or had spectra below a similarity of 0.9 compared to library spectra. Technician expert judgement was used in difficult cases.<br />
<br />
The HPLC derived diagnostic photopigment concentrations were analyzed using the ChemTax matrix factorization program (Mackey 1996).&nbsp; This program uses the steepest decent algorithm to determine the best fit based on an initial estimate of pigment ratios for algal classes.&nbsp; The initial pigment ratio matrix used in the Chemtax analysis was derived from:&nbsp; Mackey M.D., Mackey D.J., Higgins H.W., &amp; Wright S.W.&nbsp; 1996.&nbsp; CHEMTAX- a program for estimating class abundances from chemical markers: application to HPLC measurements of phytoplankton.&nbsp; Marine Ecology Progress Series 144: 265-283, and consisted of nine photopigments (alloxanthin, antheraxanthin, chlorophyll b, total chlorophyll a (chlorophyll a + chlorophyllide a), fucoxanthin, lutein, peridinin, violaxanthin, and zeaxanthin) for five algal groups that constitute the bulk of the phytoplankton community in the Neuse River and Estuary (chlorophytes, cryptophytes, cyanobacteria, diatoms, and dinoflagellates).&nbsp; In order to reduce the variation of pigment ratios due to large changes in phytoplankton species composition with depth, season, and salinity regime, homogenous data groupings of the HPLC pigment data were performed prior to running on Chemtax:&nbsp; HPLC pigment data was grouped by Depth Level (surface or bottom) then by Season (winter, spring, summer and fall) then by Salinity regime (oligohaline: &lt;5.0 ppt, mesohaline: 5.01 - 18.0 ppt, polyhaline: &gt;18.01 ppt).&nbsp; When there were less than 10 samples in a given homogenous grouping (Chemtax requires at least 10 samples per run), the data was grouped by oligohaline + mesohaline or mesohaline + polyhaline (This is indicated in the comments section).<br />
<br />
Distance (in river kilometers) was calculated using ESRI ArcGIS software.&nbsp; Distances were calculated using projected station locations (North Carolina State Plane 1983 meters projection).&nbsp; Distances from station 0 through 30 (upper river stations) were measured along the main channel of the river. Distances from stations 30 to 180 were measured as straight lines between stations</p>
Funding provided by NSF Division of Ocean Sciences (NSF OCE) Award Number: OCE-0825466 Award URL: http://www.nsf.gov/awardsearch/showAward.do?AwardNumber=0825466
completed
Hans Paerl
University of North Carolina at Chapel Hill
252-726-6841
3431 Arendell Street
Morehead City
NC
28557
US
hans_paerl@unc.edu
pointOfContact
asNeeded
Dataset Version: 1
Unknown
Date
Year
Season
Station
Source
Depth
YSI_Time
YSI_Depth
YSI_Temp
YSI_SpecCond
YSI_Salinity
YSI_DOsat
YSI_DO
YSI_pH
YSI_Turbidity
YSI_Chlraw
YSI_Chl
YSI_BP
Secchi
Kd
Cdom_Corrected
POC
PN
CtoN
DOC
DIC
NO3_NO2
NH4
DIN
TDN
DON
PO4
NtoP
SiO2
Chla_IWS
Correct_Chla_IV
PPR
Chlide_a
Chl_c1c2
Perid_corr
But_fuco
Phide_a
Fuco_corr
Hex_fuco
Neo
Pras
Viola
Diadino
Anth
Myxo
Allo_corr
Diato
Monado
Lut
Zea_corr
Gyro
Cantha
Chl_b_corr
DV_chl_a
Chl_a_corr
Echin
Phytin_a
B_car
TotalChla
ISO_DateTime
Station_Description
km0
Lat
Lon
spherical underwater quantum sensor (LI-COR LI-193SA)
HPLC system
Lachat/Zellweger Analytics QuikChem 8000 flow injection autoanalyzer
Shimadzu TOC-5000A Analyzer
secchi disk
PE 2400 Series II CHNS/O Analyzer
Hydrolab Data Sonde 3
Yellow Springs Instruments (YSI Incoporated, Ohio) multiparameter sonde (Model 6600 or 6600 EDS-S Extended Deployment System)
Turner Designs TD-700 fluorometer
in-line photodiode array spectrophotometer
plastic Van Dorn sampler
theme
None, User defined
date
year
season
station
No BCO-DMO term
depth
time of day
water temperature
conductivity
salinity
O2_sat_pcnt
dissolved Oxygen
pH
turbidity
chl_raw
fluorescence
barometric pressure
depth_secchi
beam attenuation
colored dissolved organic matter
particulate organic Carbon (POC)
Nitrogen
Carbon to Nitrogen ratio
dissolved organic Carbon
dissolved inorganic Carbon
nitrate plus nitrite
Ammonium
Dissolved Inorganic Nitrogen
Total Dissolved Nitrogen
Dissolved Organic Nitrogen
reactive phosphorus (PO4)
silica
chlorophyll a
primary production
chlorophyllide a
sum of chlorophyll a like compounds
peridinin
19-prime-butanoyloxyfucoxanthin
p_phorbide_a
fucoxanthin
19-prime-hexanoyloxyfucoxanthin
neoxanthin
prasinoxanthin
violaxanthin
diadinoxanthin
antherax
alloxanthin
diatoxanthin
monad
lutein
zeaxanthin
Gyroxanthin-Diester
chlorophyll b
divinyl chlorophyll a
p_phytin_a
carotene-beta
Date and time
site description
length
latitude
longitude
featureType
BCO-DMO Standard Parameters
LI-COR LI-193 PAR Sensor
High-Performance Liquid Chromatograph
Nutrient Autoanalyzer
UV Spectrophotometer-Shimadzu
Secchi Disc
CHN Elemental Analyzer
HydroLab DataSonde
YSI Sonde 6-Series
Turner Designs 700 Laboratory Fluorometer
Spectrophotometer
Van Dorn water sampler
instrument
BCO-DMO Standard Instruments
otherRestrictions
otherRestrictions
Access Constraints: none. Use Constraints: Please follow guidelines at: http://www.bco-dmo.org/terms-use Distribution liability: Under no circumstances shall BCO-DMO be liable for any direct, incidental, special, consequential, indirect, or punitive damages that result from the use of, or the inability to use, the materials in this data submission. If you are dissatisfied with any materials in this data submission your sole and exclusive remedy is to discontinue use.
Collaborative Research: Regulation of Phytoplankton Dynamics in Mid-Atlantic Estuaries Subject to Climatic Perturbations
http://paerllab.web.unc.edu/projects/modmon/
Collaborative Research: Regulation of Phytoplankton Dynamics in Mid-Atlantic Estuaries Subject to Climatic Perturbations
<p>NSF Award Abstract:</p>
<p>Climatic perturbations by drought-flood cycles, tropical storms, and hurricanes are increasingly important in Mid-Atlantic estuaries, leading to ecosystem-scale responses of the plankton system with significant trophic implications. Recent observations support an emerging paradigm that climate dominates nutrient enrichment in these ecosystems, explaining seasonal and interannual variability of phytoplankton floral composition, biomass (chl-a), and primary production (PP). This project will evaluate this paradigm in the two largest estuaries in the United States, Chesapeake Bay (CB) and Albemarle-Pamlico Sound-Neuse River Estuary (APS-NRE) by quantifying responses to climatic perturbations. This project will: (1) resolve long-term trends of plankton biomass/production from high variability driven by climatic forcing, such as drought-flood cycles that generate significant departures from the norm; (2) quantify the role of episodic wind and precipitation events, such as those associated with frontal passages, tropical storms, and hurricanes, that evoke consequential spikes of biomass/production outside the resolution of traditional methods. The field program will focus on event-scale forcing of phytoplankton dynamics by collecting shipboard, aircraft remote sensing, and satellite (SeaWiFS, MODIS-A) data, analyzing extensive monitoring data for CB and APS-NRE to develop context, and quantifying effects of climatic perturbations on phytoplankton dynamics as departures from long-term averages. The rapid-response sampling will be paired with numerical simulations using coupled hydrodynamic biogeochemical models based on the Regional Ocean Modeling System (ROMS). This combination of observations and modeling will be used to explore mechanistic links and test empirical relationships obtained from field data.</p>
<p>Intellectual Merit. Drought-flood cycles, tropical storms, and hurricanes are occurring at increasing severity and frequency, exerting significant pressures on land margin ecosystems. Research and monitoring in these ecosystems has focused singularly on eutrophication for nearly five decades. Recognition of climatic perturbations as the underlying cause of phytoplankton variability represents a significant departure from this singular focus. This project will combine observations and modeling to significantly extend our knowledge of how climate regulates phytoplankton dynamics in estuaries. Progress in calibrating and validating hydrodynamic biogeochemical models with data collected in CB and APS-NRE by this project will lead to predictive capabilities thus far unattained, allowing us to evaluate the paradigm that climatic perturbations regulate phytoplankton dynamics in estuaries.</p>
<p>Broader Impacts: Addressing the effects of climatic perturbations on phytoplankton dynamics in estuaries with a combination of data collection, analysis, and mechanistic modeling has societal benefits for scientists and resource managers. Applications in addition to ?basic? science include the consideration of climatic forcing in designing effective nutrient management strategies. Specific impacts include: (1) quantifying the effects of climatic perturbations on planktonic processes for important estuarine-coastal ecosystems; (2) extending empirically-based water quality criteria forward by enabling predictions of floral composition, chl-a, and PP in changing climate conditions; (3) combining observations and mechanistic models to support scenario analysis, allowing us to distinguish long-term trends from variability imposed by climate. This project will offer a graduate course in physical transport processes and plankton productivity that will benefit from this research, support two Ph.D. students, and train undergraduates in NSF REU and minority outreach programs at HPL-UMCES and IMS-UNC. The main products will be peer-reviewed publications and presentations at scientific meetings. The three PIs maintain active web sites that will be used to distribute results and data.</p>
<p><em><u>NOTE:</u></em></p>
<p><em>Dr. Harding was the original Lead PI. Dr. Michael R. Roman was named as substitute PI when Dr. Harding served as a Program Director in the NSF Biological Oceanography Program for two years, and through his move to UCLA thereafter. Dr. Harding is responsible for the data holdings on this project and for coordinating their submittal to BCO-DMO.</em></p>
climate_phyto_estuaries
largerWorkCitation
project
eng; USA
oceans
-77.1222
-76.526
34.9488
35.2106
2008-01-15
2013-12-09
The two largest estuaries in the United States, Chesapeake Bay (CB) and Albemarle-Pamlico Sound- Neuse River Estuary (APS-NRE).
0
BCO-DMO catalogue of parameters from Biological, chemical, and physical water quality indicators of the Neuse River, North Carolina from 2008 through 2013
Biological and Chemical Oceanography Data Management Office (BCO-DMO)
Unavailable
508-289-2009
WHOI MS#36
Woods Hole
MA
02543
USA
info@bco-dmo.org
http://www.bco-dmo.org
Monday - Friday 8:00am - 5:00pm
For questions regarding this resource, please contact BCO-DMO via the email address provided.
pointOfContact
http://lod.bco-dmo.org/id/dataset-parameter/767543.rdf
Name: Date
Units: unitless
Description: Date of water sample collection ; filtration ; and in situ measurements.
http://lod.bco-dmo.org/id/dataset-parameter/767544.rdf
Name: Year
Units: unitless
Description: Year of sampling
http://lod.bco-dmo.org/id/dataset-parameter/767545.rdf
Name: Season
Units: unitless
Description: The season when the water sample was collected and filtered and when the in situ measurements were performed in the field.
http://lod.bco-dmo.org/id/dataset-parameter/767546.rdf
Name: Station
Units: unitless
Description: The name of the fixed sampling station.
http://lod.bco-dmo.org/id/dataset-parameter/767547.rdf
Name: Source
Units: unitless
Description: The organization that conducted the sampling.
http://lod.bco-dmo.org/id/dataset-parameter/767548.rdf
Name: Depth
Units: meters (m)
Description: Depth level from which the water sample was collected and where the in situ measurements were made (S=surface ; B=bottom Surface (S) refers to a surface water sample or in situ measurement taken at a depth of approximately 0.2 meters. Bottom (B) refers to a bottom water sample or in situ measurement taken at a depth of approximately 0.5 meters above the sediment layer. Surface water samples were collected by submerging 10 liter high-density polyethylene containers just below the water surface or by filling the containers with surface water collected from bucket casts. Bottom water samples were collected with a horizontal plastic Van Dorn sampler. Starting December 2007 ; all samples collected with diaphragm pump and a weighted ; marked hose. All containers were kept in dark coolers at ambient temperature during transport to the laboratory. All filtration was done within a few hours of collection and when conditions permitted ; on board the research vessel.
http://lod.bco-dmo.org/id/dataset-parameter/767549.rdf
Name: YSI_Time
Units: unitless
Description: Exact time (hours:minutes:seconds) when the in situ measurements were made. This time is an approximate water sampling time.
http://lod.bco-dmo.org/id/dataset-parameter/767550.rdf
Name: YSI_Depth
Units: meters (m)
Description: Exact depth (meters) where the in situ measurements were made.
http://lod.bco-dmo.org/id/dataset-parameter/767551.rdf
Name: YSI_Temp
Units: degrees Celsius
Description: In situ water temperature
http://lod.bco-dmo.org/id/dataset-parameter/767552.rdf
Name: YSI_SpecCond
Units: milli Siemens per centimeter
Description: In situ specific conductivity
http://lod.bco-dmo.org/id/dataset-parameter/767553.rdf
Name: YSI_Salinity
Units: parts per thousand
Description: In situ salinity
http://lod.bco-dmo.org/id/dataset-parameter/767554.rdf
Name: YSI_DOsat
Units: unitless (percent)
Description: In situ dissolved oxygen saturation
http://lod.bco-dmo.org/id/dataset-parameter/767555.rdf
Name: YSI_DO
Units: milligrams per liter
Description: In situ dissolved oxygen concentration
http://lod.bco-dmo.org/id/dataset-parameter/767556.rdf
Name: YSI_pH
Units: unitless
Description: In situ pH.
http://lod.bco-dmo.org/id/dataset-parameter/767557.rdf
Name: YSI_Turbidity
Units: NTU
Description: In situ turbidity
http://lod.bco-dmo.org/id/dataset-parameter/767558.rdf
Name: YSI_Chlraw
Units: relative fluorescence units
Description: In situ chlorophyll fluorescence
http://lod.bco-dmo.org/id/dataset-parameter/767559.rdf
Name: YSI_Chl
Units: micrograms per liter
Description: In situ chlorophyll concentration from fluorescence
http://lod.bco-dmo.org/id/dataset-parameter/767560.rdf
Name: YSI_BP
Units: millimeters of mercury
Description: Surface barometric pressure
http://lod.bco-dmo.org/id/dataset-parameter/767561.rdf
Name: Secchi
Units: meters
Description: Depth at which the secchi disk is no longer visible
http://lod.bco-dmo.org/id/dataset-parameter/767562.rdf
Name: Kd
Units: per meter
Description: Diffuse light attenuation coefficient
http://lod.bco-dmo.org/id/dataset-parameter/767563.rdf
Name: Cdom_Corrected
Units: microgram per liter of quinine sulfate.
Description: Colored or chromophoric dissolved organic (matter humic substances) concentration as microgram per liter of quinine sulfate.
http://lod.bco-dmo.org/id/dataset-parameter/767564.rdf
Name: POC
Units: micrograms of carbon per liter
Description: Particulate organic carbon concentration
http://lod.bco-dmo.org/id/dataset-parameter/767565.rdf
Name: PN
Units: micrograms of nitrogen per liter
Description: Particulate nitrogen concentration
http://lod.bco-dmo.org/id/dataset-parameter/767566.rdf
Name: CtoN
Units: unitless
Description: Calculated molar ratio of particulate organic carbon
http://lod.bco-dmo.org/id/dataset-parameter/767567.rdf
Name: DOC
Units: micromolar
Description: Dissolved organic carbon concentration
http://lod.bco-dmo.org/id/dataset-parameter/767568.rdf
Name: DIC
Units: milligrams of carbon per liter
Description: Dissolved inorganic carbon concentration
http://lod.bco-dmo.org/id/dataset-parameter/767569.rdf
Name: NO3_NO2
Units: micrograms of nitrogen per liter
Description: Nitrate plus nitrite concentration
http://lod.bco-dmo.org/id/dataset-parameter/767570.rdf
Name: NH4
Units: micrograms of nitrogen per liter
Description: Ammonium concentration
http://lod.bco-dmo.org/id/dataset-parameter/767571.rdf
Name: DIN
Units: micrograms of nitrogen per liter
Description: Calculated dissolved inorganic nitrogen concentration
http://lod.bco-dmo.org/id/dataset-parameter/767572.rdf
Name: TDN
Units: micrograms of nitrogen per liter
Description: Total dissolved nitrogen concentration organic plus inorganic species
http://lod.bco-dmo.org/id/dataset-parameter/767573.rdf
Name: DON
Units: micrograms of nitrogen per liter
Description: Calculated dissolved organic nitrogen concentration
http://lod.bco-dmo.org/id/dataset-parameter/767574.rdf
Name: PO4
Units: micrograms of phosphorus per liter
Description: Orthophosphate concentration
http://lod.bco-dmo.org/id/dataset-parameter/767575.rdf
Name: NtoP
Units: miligrams nitrogen per liter (mg N/L)
Description: The calculated molar ratio of nitrogen (N) to phosphorus (P)
http://lod.bco-dmo.org/id/dataset-parameter/767576.rdf
Name: SiO2
Units: micromolar
Description: Silica concentration
http://lod.bco-dmo.org/id/dataset-parameter/767577.rdf
Name: Chla_IWS
Units: micrograms per liter
Description: Chlorophyll a concentration measured by in vitro fluorometry (micrograms per liter) integrated throughout the water column to 2x the secchi depth. Water samples for this measurement were collected using the integrated water sampler IWS) which collects vertically integrated water samples.
http://lod.bco-dmo.org/id/dataset-parameter/767578.rdf
Name: Correct_Chla_IV
Units: micrograms per liter
Description: Chlorophyll a concentration measured by in vitro fluorometry
http://lod.bco-dmo.org/id/dataset-parameter/767579.rdf
Name: PPR
Units: milligrams of C per meter cubed per hour
Description: Primary productivity by light/dark 14C bicarbonate incorporation
http://lod.bco-dmo.org/id/dataset-parameter/767580.rdf
Name: Chlide_a
Units: micrograms per liter
Description: Chlorophyllide a concentration by HPLC analysis
http://lod.bco-dmo.org/id/dataset-parameter/767581.rdf
Name: Chl_c1c2
Units: micrograms per liter
Description: Chlorophyll c1 and c2 concentration by HPLC analysis
http://lod.bco-dmo.org/id/dataset-parameter/767582.rdf
Name: Perid_corr
Units: micrograms per liter
Description: Peridinin concentration by HPLC analysis
http://lod.bco-dmo.org/id/dataset-parameter/767583.rdf
Name: But_fuco
Units: micrograms per liter
Description: 19'-Butanoyloxyfucoxanthin concentration by HPLC analysis
http://lod.bco-dmo.org/id/dataset-parameter/767584.rdf
Name: Phide_a
Units: micrograms per liter
Description: Pheophorbide-a concentration by HPLC analysis
http://lod.bco-dmo.org/id/dataset-parameter/767585.rdf
Name: Fuco_corr
Units: micrograms per liter
Description: Fucoxanthin concentration by HPLC analysis
http://lod.bco-dmo.org/id/dataset-parameter/767586.rdf
Name: Hex_fuco
Units: micrograms per liter
Description: 19'-Hexanoyloxyfucoxanthin concentration by HPLC analysis
http://lod.bco-dmo.org/id/dataset-parameter/767587.rdf
Name: Neo
Units: micrograms per liter
Description: 9'-cis Neoxanthin concentration by HPLC analysis
http://lod.bco-dmo.org/id/dataset-parameter/767588.rdf
Name: Pras
Units: micrograms per liter
Description: Prasinoxanthin concentration by HPLC analysis
http://lod.bco-dmo.org/id/dataset-parameter/767589.rdf
Name: Viola
Units: micrograms per liter
Description: Violaxanthin concentration by HPLC analysis
http://lod.bco-dmo.org/id/dataset-parameter/767590.rdf
Name: Diadino
Units: micrograms per liter
Description: Diadinoxanthin concentration by HPLC analysis
http://lod.bco-dmo.org/id/dataset-parameter/767591.rdf
Name: Anth
Units: micrograms per liter
Description: Antheraxanthin concentration by HPLC analysis
http://lod.bco-dmo.org/id/dataset-parameter/767592.rdf
Name: Myxo
Units: micrograms per liter
Description: Myxoxanthophyll concentration by HPLC analysis
http://lod.bco-dmo.org/id/dataset-parameter/767593.rdf
Name: Allo_corr
Units: micrograms per liter
Description: Alloxanthin concentration by HPLC analysis
http://lod.bco-dmo.org/id/dataset-parameter/767594.rdf
Name: Diato
Units: micrograms per liter
Description: Diatoxanthin concentration by HPLC analysis
http://lod.bco-dmo.org/id/dataset-parameter/767595.rdf
Name: Monado
Units: micrograms per liter
Description: Monadoxanthin concentration by HPLC analysis
http://lod.bco-dmo.org/id/dataset-parameter/767596.rdf
Name: Lut
Units: micrograms per liter
Description: Lutein concentration by HPLC analysis
http://lod.bco-dmo.org/id/dataset-parameter/767597.rdf
Name: Zea_corr
Units: micrograms per liter
Description: Zeaxanthin concentration by HPLC analysis
http://lod.bco-dmo.org/id/dataset-parameter/767598.rdf
Name: Gyro
Units: micrograms per liter
Description: Gyroxanthin concentration by HPLC analysis
http://lod.bco-dmo.org/id/dataset-parameter/767599.rdf
Name: Cantha
Units: micrograms per liter
Description: Canthaxanthin concentration by HPLC analysis
http://lod.bco-dmo.org/id/dataset-parameter/767600.rdf
Name: Chl_b_corr
Units: micrograms per liter
Description: Chlorophyll b concentration by HPLC analysis
http://lod.bco-dmo.org/id/dataset-parameter/767601.rdf
Name: DV_chl_a
Units: micrograms per liter
Description: Divinyl chlorophyll a concentration by HPLC analysis
http://lod.bco-dmo.org/id/dataset-parameter/767602.rdf
Name: Chl_a_corr
Units: micrograms per liter
Description: Chlorophyll a concentration by HPLC analysis
http://lod.bco-dmo.org/id/dataset-parameter/767603.rdf
Name: Echin
Units: micrograms per liter
Description: Echinenone concentration by HPLC analysis
http://lod.bco-dmo.org/id/dataset-parameter/767604.rdf
Name: Phytin_a
Units: micrograms per liter
Description: Pheophytin a concentration by HPLC analysis
http://lod.bco-dmo.org/id/dataset-parameter/767605.rdf
Name: B_car
Units: micrograms per liter
Description: ?-Carotene concentration by HPLC analysis
http://lod.bco-dmo.org/id/dataset-parameter/767606.rdf
Name: TotalChla
Units: micrograms per liter
Description: Sum of chlorophyll a and chlorophyllide a concentrations by HPLC analysis . Concentrations below detection assumed to by zero for this calculation.
http://lod.bco-dmo.org/id/dataset-parameter/767607.rdf
Name: ISO_DateTime
Units: unitless
Description: Date and YSI_Time columns combined into ISO 8601 date format
http://lod.bco-dmo.org/id/dataset-parameter/767608.rdf
Name: Station_Description
Units: unitless
Description: The physical location of the sampling station ; such as at or near a particular river marker ; buoy ; road or bridge. Lists other names that may also be used to refer to this station.
http://lod.bco-dmo.org/id/dataset-parameter/767609.rdf
Name: km0
Units: kilometers (km)
Description: The distance of the sampling station from station 0.
http://lod.bco-dmo.org/id/dataset-parameter/767610.rdf
Name: Lat
Units: decimal degrees
Description: North latitude of station in decimal degrees
http://lod.bco-dmo.org/id/dataset-parameter/767611.rdf
Name: Lon
Units: decimal degrees
Description: West longitude of station in decimal degrees
GB/NERC/BODC > British Oceanographic Data Centre, Natural Environment Research Council, United Kingdom
Biological and Chemical Oceanography Data Management Office (BCO-DMO)
Unavailable
508-289-2009
WHOI MS#36
Woods Hole
MA
02543
USA
info@bco-dmo.org
http://www.bco-dmo.org
Monday - Friday 8:00am - 5:00pm
For questions regarding this resource, please contact BCO-DMO via the email address provided.
pointOfContact
1186243
https://darchive.mblwhoilibrary.org/bitstream/1912/24144/1/dataset-767391_neuse-river-estuary-wq__v1.tsv
download
https://doi.org/10.1575/1912/bco-dmo.767391.1
download
onLine
dataset
<p>Bi-weekly water sampling and in situ measurements were performed at fixed sampling stations.&nbsp; Water samples and in situ measurements were collected at the surface (approximately 0.2 meters) and at the bottom of the water column (approximately 0.5 meters from the sediment layer).&nbsp; These data are included in the worksheet titled "NRE Dataset."&nbsp; In situ measurements were also performed throughout the water column in 0.5 meter depth increments.&nbsp; These data are included in the worksheet titled "NRE YSI Profiles."&nbsp; Parameters measured include: temperature, salinity, specific conductivity, dissolved oxygen (DO), pH, chlorophyll fluorescence, photosynthetically active radiation (PAR), turbidity, barometric pressure, secchi depth, colored dissolved organic matter (CDOM), particulate organic carbon (POC) and nitrogen (PN), dissolved organic and inorganic carbon, dissolved inorganic nutrient concentrations (nitrate/nitrite, ammonium, total dissolved nitrogen, phosphate and silicic acid), chlorophyll a, primary productivity and diagnostic phytoplankton pigment concentrations (chlorophylls and carotenoids).&nbsp; Calculated parameters include:&nbsp; diffuse light attenuation coefficient (Kd), carbon to nitrogen molar ratio (C:N), dissolved inorganic nitrogen (DIN; nitrate/nitrite plus ammonium), dissolved organic nitrogen (DON; total dissolved nitrogen minus dissolved inroganic nitrogen) and the nitrogen to phosporus molar ratio (N:P).&nbsp;&nbsp;</p>
<p>Methods<br />
Water sampling was conducted bi-weekly. When collection was split over two days, a single date was used based on the upstream or majority stations.</p>
<p>Stations were selected to cover the entire length of the Neuse River Estuary from Streets Ferry Bridge (Station 0) to the mouth of the estuary where it flows into Pamlico Sound.&nbsp; When possible, efforts were made to select locations with key stationary features (channel markers, buoys and land markers) to allow easy station identification in the field.<br />
<br />
Surface water samples were collected by submerging 10 liter high-density polyethylene containers just below the water surface or by filling the containers with surface water collected from bucket casts.&nbsp; Bottom water samples were collected with a horizontal plastic Van Dorn sampler. Starting December 2007, all samples collected with diaphragm pump and a weighted, marked hose. All containers were kept in dark coolers at ambient temperature during transport to the laboratory.&nbsp; All filtration was done within a few hours of collection and when conditions permitted, on board the research vessel.<br />
<br />
Prior to the 09/13/2000 sampling date, in situ measurements were performed at discrete depths using a Hydrolab Data Sonde 3 equipped with a multiprobe and SVR3 display logger.&nbsp; Beginning on the 09/13/2000 sampling date, in situ measurements were performed at discrete depths on the sunlit side of the research vessel using a Yellow Springs Instruments (YSI Incoporated, Ohio) multiparameter sonde (Model 6600 or 6600 EDS-S Extended Deployment System) equipped with a YSI conductivity/temperature probe (Model 6560), a YSI chlorophyll probe (Model 6025), a YSI pH probe (Model 6561 or 6566), a YSI pulsed dissolved oxygen probe (Model 6562), a self cleaning YSI turbidity probe (Model 6026 or 6136), and beginning on the 07/30/2003 sampling date, a flat Li-Cor sensor (UWQ-PAR 6067).&nbsp; The YSI sonde was coupled to a either a YSI 610 DM datalogger or a YSI 650 MDS Multi-parameter Display System datalogger.&nbsp; In situ measurements were performed at the surface (approximately 0.2 meters) and at the bottom of the water column (approximately 0.5 meters from the sediment layer).&nbsp; These data are included in the worksheet titled "NRE Dataset."&nbsp; In situ measurements were also performed throughout the water column in 0.5 meter depth increments.&nbsp; These data are included in the worksheet titled "NRE YSI Profiles."&nbsp; The data were stored on the datalogger and downloaded to Ecowin software upon return to the laboratory.</p>
<p>The secchi disk was deployed off of the sunlit side of the research vessel.&nbsp; The depth (in meters) at which the secchi disk was no longer visible by the naked eye was recorded as the secchi depth.<br />
<br />
The diffuse light attenuation coefficient, Kd, was calculated from depth profiles of photosynthetically active radiation (PAR, 400-700 nm).&nbsp; Prior to the 07/30/2003 sampling date, PAR measurements were performed with a spherical underwater quantum sensor (LI-COR LI-193SA) coupled to a LI-COR LI-1000 datalogger.&nbsp; Beginning on the 07/30/2003 sampling date, a flat underwater quantum sensor (LI-COR LI-193SA) attached to a Yellow Springs Instruments YSI 6600 or YSI 6600 EDS-S sonde was used to measure PAR.&nbsp; Measurements of PAR were performed on the sunlit side of the research vessel in 0.5 meter depth increments, beginning just below the water surface.&nbsp; The diffuse attenuation coefficient is the slope of the linear regression between natural log transformed PAR data and depth.&nbsp;<br />
<br />
Colored dissolved organic matter (CDOM) was measured using a Turner Designs TD-700 fluorometer configured with a near-UV mercury vapour lamp, a 350 nm excitation filter, and a 410–600 nm emission filter. The fluorometer was calibrated to quinine sulfate (QS) solutions made up in 2 N sulfuric acid. Water samples were vacuum filtered (less than 25 kilopascal) using pre-combusted Whatman glass microfibre filters (GF/F) and the filtrate was stored in scintillation vials in the dark at 4 degrees Celsius until fluorometric analysis.&nbsp; The official decision (3/2/2017) is that cdom results from 12/1/2003 through 4/25/2011 would be multiplied by a corrective factor of 2.0.&nbsp; Results for sample date of 5/9/2011 and after do not need correcting.&nbsp; It is believed the stock solution was made wrong, making a 1L recipe for 600 ug/L in a 500 ml flask equals 1200 ug/L stock solution.&nbsp; Standards were still calibrated according to recipe, but were actually 2x as strong.&nbsp;<br />
<br />
&nbsp;The official decision (3/2/2017) is that cdom results from 12/1/2003 through 4/25/2011 would be multiplied by a corrective factor of 2.0.&nbsp; Results for sample date of 5/9/2011 and after do not need correcting.&nbsp; It is believed the stock solution was made wrong, making a 1L recipe for 600 ug/L in a 500 ml flask equals 1200 ug/L stock solution.&nbsp; Standards were still calibrated according to recipe, but were actually 2x as strong.&nbsp;<br />
<br />
Particulate organic carbon (POC) concentrations were determined by elemental analysis of material collected on pre-combusted Whatman GF/F glass fiber filters.&nbsp; Carbonates were removed from the filters by vapor phase acidification using concentrated hydrochloric acid (HCl).&nbsp; After drying at 60 0C, the filters were rolled in tin disks and injected into a PE 2400 Series II CHNS/O Analyzer calibrated with acetanilide ending in June 2014.&nbsp; Starting on the Neuse River sample date of June 2, 2014, a Costech Analytical Technologies, Inc. Elemental Combustion System CHNS-O ECS 4010 was used for elemental analysis by "flash combustion/chromatographic separation and multi-detector techniques".&nbsp; The Costech Instrument utilizes EAS Clarity Software.&nbsp; Atropine standards are used to develop a calibration curve (C 70.56%, N 4.84%, and carbon response ratio of 0.025 +/-0.003).&nbsp; NIST Buffalo River Sediment Reference Material 8704 (C 3.351% +/-0.017, N 0.20% +/-0.04) and/or Acetanilide Bypass (C 71.09%, N 10.36%, carbon response ratio of 0.055 +/- 0.003) may used for calibration or a check standard.</p>
<p>The molar ratio of particulate organic carbon (POC) to particulate nitrogen (PN), or C:N, was calculated by dividing POC by PN.&nbsp; (Carbon ug/L /12.011)/(Nitrogen ug/L/14.007).<br />
<br />
Dissolved organic carbon (DOC) concentration was measured using a Shimadzu TOC-5000A Analyzer:&nbsp; Water samples were vacuum filtered (less than 25 kilopascal) using pre-combusted Whatman glass microfibre filters (GF/F).&nbsp; The filtrate was stored in pre-combusted glass scintillation vials with Teflon closures and frozen at -20 degrees Celsius until analysis.&nbsp; The Shimadzu TOC-5000A Analyzer uses high temperature catalytic oxidation followed by non-dispersive infrared analysis of the CO2 produced.&nbsp; Samples were acidified to a pH less than 2 and sparged with air before they were analyzed for non-volatile organic carbon.&nbsp; DOC values in 1996 were run from previously run nutrient samples. Starting February 2018, all stations were collected.&nbsp; Prior to Feb. 2018 only NR 0, 30, 70, 100, 120, and 160 surface and bottom stations were measured.<br />
<br />
Nitrate/nitrite (NO3- / NO2-) concentration was determined using a Lachat/Zellweger Analytics QuikChem 8000 flow injection autoanalyzer (Milwaukee, WI, USA) using method FIA 31-107-04-1-C:&nbsp; Water samples were vacuum filtered (less than 25 kiloPascals) using pre-combusted Whatman glass microfibre filters (GF/F).&nbsp; The filtrate was stored in high-density polyethylene bottles and frozen at -20 degrees Celsius until analysis.&nbsp; Two replicates were run from the same bottle.&nbsp; Method detection limits (MDL, µg L-1) were: before 4Nov02 = 1.06; beginning 4Nov02 = 3.68; beginning 11Jul06 = 0.6; beginning 1Dec09 = 0.27; beginning 13Feb12 = 0.36; beginning 18Feb15 = 0.71.&nbsp; MDL was changed to 0.88 on a sample date of 8/21/2017.<br />
<br />
Ammonium (NH4+) concentration was determined using a Lachat/Zellweger Analytics QuikChem 8000 flow injection autoanalyzer (Milwaukee, WI) using method FIA 31-107-06-1-A/B:&nbsp; Water samples were vacuum filtered (less than 25 kiloPascals) using pre-combusted Whatman glass microfibre filters (GF/F).&nbsp; The filtrate was stored in high-density polyethylene bottles and frozen (-20 degrees Celsius) until analysis.&nbsp; Two replicates were run from the same bottle.&nbsp; &nbsp;Method detection limits (MDL, µg L-1) were: before 4Nov02 = 4.69; beginning 4Nov02 = 4.31; beginning 11Jul06 = 2.55; beginning 1Dec09 = 3.98; beginning 13Feb12 = 2.87; beginning 18Feb15 = 3.34.&nbsp; MDL was changed to 1.05 on sample date 8/21/2017.<br />
<br />
Dissolved inorganic nitrogen (DIN) concentration was calculated by summing nitrate/nitrite (NO3- / NO2-) and ammonium (NH4+).&nbsp; If either NO3- / NO2- or NH4+ were below the detection limit (-9999), they were taken to be zero for this calculation.<br />
<br />
Total dissolved nitrogen (TDN) was measured by in-line digestion using the Lachat/Zellweger Analytics QuikChem 8000 flow injection autoanalyzer (Milwaukee, WI, USA) using method FIA 31-107-04-3-B for low total nitrogen for brackish/fresh waters (detection level: 0.1 - 5.0 milligrams nitrogen per liter):&nbsp; Water samples were vacuum filtered (less than 25 kiloPascals) using pre-combusted Whatman glass microfibre filters (GF/F).&nbsp; The filtrate was stored in high-density polyethylene bottles and frozen at -20 degrees Celsius until analysis.&nbsp; Two replicates were run from the same bottle.&nbsp; Total dissolved nitrogen by in-line digestion works by oxidizing all the nitrogen compounds to nitrate by heating to 100 degrees Celsius and adding energy via UV light.&nbsp; The pH is dropped from 9.1 to 3 during the decomposition.&nbsp; The entire digestion occurs prior to the injection valve.&nbsp; The nitrate/nitrite concentration is then determined using standard colorimetric techniques similar to the strict nitrate/nitrite manifold. Method detection limits (MDL, µg L-1) were: beginning 1Nov04 = 78; beginning 11Jul06 = 35.4 beginning 1Dec09 = 25.6; beginning 13Feb12 = 36.9; beginning 14Jan13 = 19.6; beginning 18Feb15 = 10.5.&nbsp; MDL changed to 7.30 on sample date of 8/21/2017&nbsp;<br />
<br />
Dissolved organic nitrogen (DON) was calculated by subtracting dissolved inorganic nitrogen (DIN) from total dissolved nitrogen (TDN).&nbsp; If the DIN value used in the calculation was below the detection limit, it was taken to be zero for this calculation.&nbsp; At one point DON was determined by high temperature oxidation using the Antek 7000N or Antek 7000V analyzer.<br />
<br />
Orthophosphate (PO43-) was determined using a Lachat/Zellweger Analytics QuikChem 8000 flow injection autoanalyzer (Milwaukee, WI) using method FIA 31-115-01-1-F/G:&nbsp; Water samples were vacuum filtered (less than 25 kiloPascals) using pre-combusted Whatman glass microfibre filters (GF/F).&nbsp; The filtrate was stored in high-density polyethylene bottles and frozen at -20 degrees Celsius until analysis.&nbsp; Two replicates were run from the same bottle.&nbsp; Method detection limits (MDL, µg L-1) were: before 4Nov02 = 0.35; beginning 4Nov02 = 0.74; beginning 1Nov04 = 1.68; beginning 11Jul06 = 1.84; beginning 1Dec09 = 0.62; beginning 13Feb12 = 0.69; beginning 18Feb15 = 0.61.&nbsp; MDL was changed to 1.80 on the sample date of 8/21/2017.<br />
<br />
The molar ratio of nitrogen (N) to phosphorus (P), or N:P, was calculated by dividing dissolved inorganic nitrogen (DIN) by orthophosphate (PO43-) concentrations.<br />
<br />
Silicic acid (SiO2) was measured after vacuum filtration (&lt; 25 kPA) of the collected water samples through pre-combusted (3-4 hours at 450 0C) Whatman GF/F glass fiber filters.&nbsp; The filtrate was stored in high-density polyethylene bottles and frozen (-20 0C) until analysis.&nbsp; Two replicates were run from the same sample bottle.&nbsp; Nitrate plus nitrite concentrations were determined using a Lachat QuikChem 8000 flow injection autoanalyzer (Milwaukee, WI, USA).&nbsp; Method detection limits (MDL, µM) were: before 4Nov02 = 0.18; beginning 4Nov02 =1.24; beginning 1Nov04 = 1.86; beginning 11Jul06 = 0.75; beginning 1Dec09 = 0.75; beginning 13Feb12 = 0.09; beginning 18Feb15 = 0.08.&nbsp; MDL was changed to 0.03 on sample date of 8/21/2017.<br />
<br />
Chlorophyll a (Chl a) measurements prior to the 08/17/1999 sampling date were measured on a Shimadzu UV-160U spectrophotometer using the trichromatic equation following sonication (45-60 s) and overnight extraction of glass fiber filters in 90 % acetone.&nbsp; Beginning on the 08/17/1999 sampling date, Chl a concentration was measured using the modified in vitro fluorescence technique in EPA Method 445.0 (Welshmeyer 1994, Arar et al.&nbsp; 1997): Fifty milliliters of each water sample was vacuum filtered (less than 25 kilopascals) in duplicate at low ambient light conditions using 25 mm Whatman glass microfibre filters (GF/F).&nbsp; The filters were blotted dry, wrapped in foil and frozen immediately at -20 degrees Celsius until analysis.&nbsp; Chlorophyll a was extracted from the filter using a tissue grinder and 10 mL of 90 percent reagent grade aqueous acetone (v/v with deionized water, Fisher Scientific NF/FCC Grade). The samples remained in the acetone overnight at -20 degrees Celsius.&nbsp; The extracts were filter-clarified using a centrifuge and analyzed on a Turner Designs TD-700 fluorometer that was configured for the non-acidification method of Welschmeyer (1994).&nbsp; The value reported is the average chlorophyll a concentration measured from the two filters.&nbsp; The fluorometer was calibrated with a known concentration of pure Chl a that was determined using a Shimadzu UV-160U spectrophotometer and the extinction coefficients of Jeffrey and Humphrey (1975).&nbsp; The calibration was checked daily against a solid secondary standard (Turner Designs, proprietary formula).&nbsp; As of August 2010, fluorescence was also measured on a TurnerDesigns Trilogy fluorometer.&nbsp; References: 1.&nbsp; Welschmeyer, N.A. 1994. Fluorometric analysis of chlorophyll a in the presence of chlorophyll b and pheopigments. Limnol. Oceanogr. 39:1985-1992.&nbsp; 2.&nbsp; Arar, E.J., W.L. Budde, and T.D. Behymer.&nbsp; 1997.&nbsp; Methods for the determination of chemical substances in marine and environmental matrices.&nbsp; EPA/600/R-97/072.&nbsp; National Exposure Research Laboratory, U.S. Environmental Protection Agency, Cincinnati, Ohio.&nbsp; 3. Jeffrey, S.W., R.F.C. Mantoura, and S.W. Wright.&nbsp; 1997.&nbsp; Phytoplankton pigments in oceanography:&nbsp; Guidelines to modern methods.&nbsp; UNESCO Publishing, Paris, France.</p>
<p>Spec was used to determine chla up until AUGUST 1999.&nbsp; The spec results before Aug 1999 are corrected to correspond to the change in analysis with the Turner Designs fluorometer.&nbsp; Figure 1 presents raw and log transformed regressions between the HPLC and SPEC determinations of chl a in the Neuse during calendar year 1998.&nbsp; It appears that the SPEC method produces chl a values that are roughly 15 per cent higher than the HPLC method.&nbsp; Figure 2 presents similar regressions between HPLC and FLUO determinations of chl a in the Neuse from August – December of 1999.&nbsp; It appears that the FLUO method produces chl a values that are roughly 67 per cent higher than the HPLC method.&nbsp; These figures suggest two important problems for utilizing existing chl a data in water quality modeling in the Neuse; (i) a decision must be made which analysis technique will be accepted as the standard for determining chl a, and (ii) a correction must be applied to equilibrate IMS chl a values determined by the SPEC and FLUO methods.<br />
<br />
Primary Productivity rate was measured using an adaptation of Steeman Nielsen's (1952) 14C bicarbonate method (Paerl et al. 1998).&nbsp; This method of measuring primary productivity allows direct measurement of carbon uptake and measures only net photosynthesis:&nbsp; Water samples were stored in 10 Liter high density polyethylene containers overnight in the research pond, a flow through system that receives water from the adjacent Bogue Sound, thereby simulating ambient water temperatures.&nbsp; The following morning the water samples were removed from the pond and transported to the laboratory for analysis.&nbsp; Water samples (76 milliliters) were added to three clear plastic square bottles to determine light uptake of carbon in triplicate and to 1 dark bottle to determine dark uptake of carbon.&nbsp; A solution of radioactive carbonate (300 microliters) was added to each bottle.&nbsp; The bottles were incubated for 4 hours in the pond.&nbsp; The light bottles were incubated underneath a field light simulator, while the dark bottles were incubated in a covered perforated bucket that was submerged in the pond.&nbsp; The FLS was used to simulate the ambient light conditions that phytoplankton are exposed to in the estuary (mixing conditions).&nbsp; The FLS is comprised of a rotating wheel with varying levels of screening.&nbsp; During the incubation period, photosynthetically active radiation (PAR) measurements were performed using a 2 pi Li-Cor LI-192SA spherical quantum sensor attached to a Li-Cor data logger.&nbsp; After the incubation period, the samples were returned to the laboratory, shaken and the entire contents were gently vacuum filtered (less than 25 kilopascals) using 25 mm Whatman glass microfibre filters (GF/F).&nbsp; The filters were placed in wooden drying trays and treated with concentrated hydrochloric acid fumes for 40 minutes to an hour to remove inorganic 14C.&nbsp; The filters were folded in half and placed in 7 milliliter plastic scintillation vials.&nbsp; Five milliliters of liquid scintillation cocktail (ecolume or cytoscint) was added to the vials.&nbsp; The vials were capped, shaken, stored in the dark for 3-24 hours and then assayed for radioactivity using a Beckman liquid scintillation counter.&nbsp; In addition to the samples, triplicate voucher samples were used to quantify the radioactivity of the 14C added.&nbsp; Voucher samples consisted of 100 microliter of 14C and 100 microliters of phenylethylamine.&nbsp; These vials also received 5 milliliters of liquid scintillation cocktail.&nbsp; A background vial and two 14C background standards were used.&nbsp; &nbsp;The quantity of carbon fixed is proportional to the fraction of radioactive carbon assimilated.&nbsp; (Paerl, H.W., J.L. Pinckney, J.M. Fear, and B.L. Peierls 1998. Ecosystem responses to internal and watershed organic matter loading: consequences for hypoxia in the eutrophying Neuse River Estuary, North Carolina, USA. Marine Ecology Progress Series 166: 17-25; Steemann Nielsen, E. 1952. The use of radio-active carbon (C14) for measuring organic production in the sea. Journal du Conseil permanent international pour L'Exploration de la Mer 18: 117-140)<br />
<br />
Diagnostic phytoplankton photopigments were identified, separated and quantified by high performance liquid chromatography coupled to an in-line photodiode array spectrophotometer (Jeffrey et al.&nbsp; 1997):&nbsp; Known volumes of water sample (500-1000 milliliters, enough to obtain color on the filter) were vacuum filtered (less than 25 kiloPascals) through 25 or 47 millimeter Whatman glass microfibre filters (GF/F) under reduced light conditions.&nbsp; The filters were blotted dry, folded in half, wrapped in foil and then immediately frozen at -20 degrees Celsius until analysis.&nbsp; The filters were placed in 15 milliliter centrifuge tubes containing 1.5-3.0 milliliters of 100% acetone (HPLC Grade), sonicated for 30-60 seconds using a Fisher Sonic Dismembrator 300 with microtip and extracted at -20 degrees Celsius for 12-24 hours.&nbsp; After extraction the samples were centrifuged at 4500 rpm and the supernatant (i.e.- the combined extracted pigments) collected &amp; filtered into amber glass autosampler vials using Millipex Millipore 0.45 micometer PTFE.&nbsp; Two hundred microliters of extractant from each vial was injected into the HPLC system using a Spectra Physics (now Thermo Separations Products) AS3000 autosampler and SP8800 pump, running a non-linear, 55 minute, 2-solvent gradient adapted from Van Heukelem et.al. 1994 or 1995?.&nbsp; The nonlinear, variable flow, binary gradient consisted of solvent A [80% methanol : 20% ammonium acetate (0.5 M adjusted to pH 7.2)] and B (80% methanol : 20% acetone).&nbsp; The extractant was separated into individual pigments using a series of C18 reverse-phase columns to optimize photopigment separations:&nbsp; The column order was a Rainin Microsorb guard column (0.46 x 1.5 centimeters, 3 micrometer packing) followed by a single monomeric reverse-phase C18 column (Rainin Microsorb-MV, 0.46 x 10 cm, 3 µm packing) followed by two polymeric reverse-phase C18 columns (Vydac 201TP5, 0.46 x 25 cm, 5 µm packing).&nbsp; The columns were kept at a constant 52 degrees Celsius in an Alltech 330 column heater.&nbsp; The separated pigments were then passed through an in line Shimadzu SPD-M10AV photodiode array detector which measured the absorbance of the sample/extractant, scanning the range of 350-800 nanometers every 2 seconds.&nbsp; The data was collected and analyzed using Shimadzu's EZChrom software.&nbsp; Individual pigments are identified using a combination of peak retention time and absorbance spectrum shape.&nbsp; Retention times and absorbance spectra are identified for each pigment by analyzing known pigments (either as pure standards or pigments or isolated from algal cultures).&nbsp; Pigments are quantified from their peak areas, calculated at 440nm. A calibration curve is generated by injecting various volumes of a mixed standard composed of known quantities of seven pure pigment standards (fucoxanthin, zeaxanthin, bacteriochlorophyll a, canthaxathin, chlorophyll b, chlorophyll a, echinenone and ß-carotene) and calculating the peak areas of those pigments&nbsp; &nbsp;The peak areas are regressed against the known quantities of each pigment to calculate the slope (Response Factor) for that pigment.&nbsp; Response factors for pigments we do not have reference standards for are calculated using the ratio of absorbance coefficients of each pigment to its closest structurally related reference pigment, multiplying the known pigment's response factor by that ratio. Pigments extracted from the samples are then quantified by multiplying the peak areas of a chromatogram at 440nm by the response factors. Pigment values listed as below detection were below the software threshold for peak detection or had spectra below a similarity of 0.9 compared to library spectra. Technician expert judgement was used in difficult cases.<br />
<br />
The HPLC derived diagnostic photopigment concentrations were analyzed using the ChemTax matrix factorization program (Mackey 1996).&nbsp; This program uses the steepest decent algorithm to determine the best fit based on an initial estimate of pigment ratios for algal classes.&nbsp; The initial pigment ratio matrix used in the Chemtax analysis was derived from:&nbsp; Mackey M.D., Mackey D.J., Higgins H.W., &amp; Wright S.W.&nbsp; 1996.&nbsp; CHEMTAX- a program for estimating class abundances from chemical markers: application to HPLC measurements of phytoplankton.&nbsp; Marine Ecology Progress Series 144: 265-283, and consisted of nine photopigments (alloxanthin, antheraxanthin, chlorophyll b, total chlorophyll a (chlorophyll a + chlorophyllide a), fucoxanthin, lutein, peridinin, violaxanthin, and zeaxanthin) for five algal groups that constitute the bulk of the phytoplankton community in the Neuse River and Estuary (chlorophytes, cryptophytes, cyanobacteria, diatoms, and dinoflagellates).&nbsp; In order to reduce the variation of pigment ratios due to large changes in phytoplankton species composition with depth, season, and salinity regime, homogenous data groupings of the HPLC pigment data were performed prior to running on Chemtax:&nbsp; HPLC pigment data was grouped by Depth Level (surface or bottom) then by Season (winter, spring, summer and fall) then by Salinity regime (oligohaline: &lt;5.0 ppt, mesohaline: 5.01 - 18.0 ppt, polyhaline: &gt;18.01 ppt).&nbsp; When there were less than 10 samples in a given homogenous grouping (Chemtax requires at least 10 samples per run), the data was grouped by oligohaline + mesohaline or mesohaline + polyhaline (This is indicated in the comments section).<br />
<br />
Distance (in river kilometers) was calculated using ESRI ArcGIS software.&nbsp; Distances were calculated using projected station locations (North Carolina State Plane 1983 meters projection).&nbsp; Distances from station 0 through 30 (upper river stations) were measured along the main channel of the river. Distances from stations 30 to 180 were measured as straight lines between stations</p>
Specified by the Principal Investigator(s)
<p>BCO-DMO Processing Notes:<br />
-&nbsp;added conventional header with dataset name, PI name, version date<br />
- modified parameter names to conform with BCO-DMO naming conventions<br />
- appended the AMS station coordinate information<br />
- combined the various comments fields into one Comments field.</p>
Specified by the Principal Investigator(s)
asNeeded
7.x-1.1
Biological and Chemical Oceanography Data Management Office (BCO-DMO)
Unavailable
508-289-2009
WHOI MS#36
Woods Hole
MA
02543
USA
info@bco-dmo.org
http://www.bco-dmo.org
Monday - Friday 8:00am - 5:00pm
For questions regarding this resource, please contact BCO-DMO via the email address provided.
pointOfContact
spherical underwater quantum sensor (LI-COR LI-193SA)
spherical underwater quantum sensor (LI-COR LI-193SA)
PI Supplied Instrument Name: spherical underwater quantum sensor (LI-COR LI-193SA) PI Supplied Instrument Description:Prior to the 07/30/2003 sampling date, PAR measurements were performed with a spherical underwater quantum sensor (LI-COR LI-193SA) coupled to a LI-COR LI-1000 datalogger. Beginning on the 07/30/2003 sampling date, a flat underwater quantum sensor (LI-COR LI-193SA) attached to a Yellow Springs Instruments YSI 6600 or YSI 6600 EDS-S sonde was used to measure PAR. Instrument Name: LI-COR LI-193 PAR Sensor Instrument Short Name:LI-COR LI-193 PAR Instrument Description: The LI-193 Underwater Spherical Quantum Sensor uses a Silicon Photodiode and glass filters encased in a waterproof housing to measure PAR (in the 400 to 700 nm waveband) in aquatic environments. Typical output is in micromol s-1 m-2. The LI-193 Sensor gives an added dimension to underwater PAR measurements as it measures photon flux from all directions. This measurement is referred to as Photosynthetic Photon Flux Fluence Rate (PPFFR) or Quantum Scalar Irradiance. This is important, for example, when studying phytoplankton, which utilize radiation from all directions for photosynthesis. LI-COR began producing Spherical Quantum Sensors in 1979; serial numbers for the LI-193 begin with SPQA-XXXXX (licor.com). Community Standard Description: http://vocab.nerc.ac.uk/collection/L22/current/TOOL0458/
HPLC system
HPLC system
PI Supplied Instrument Name: HPLC system PI Supplied Instrument Description:Two hundred microliters of extractant from each vial was injected into the HPLC system using a Spectra Physics (now Thermo Separations Products) AS3000 autosampler and SP8800 pump, running a non-linear, 55 minute, 2-solvent gradient adapted from Van Heukelem et.al. 1994 or 1995?. Instrument Name: High-Performance Liquid Chromatograph Instrument Short Name:HPLC Instrument Description: A High-performance liquid chromatograph (HPLC) is a type of liquid chromatography used to separate compounds that are dissolved in solution. HPLC instruments consist of a reservoir of the mobile phase, a pump, an injector, a separation column, and a detector. Compounds are separated by high pressure pumping of the sample mixture onto a column packed with microspheres coated with the stationary phase. The different components in the mixture pass through the column at different rates due to differences in their partitioning behavior between the mobile liquid phase and the stationary phase. Community Standard Description: http://vocab.nerc.ac.uk/collection/L05/current/LAB11/
Lachat/Zellweger Analytics QuikChem 8000 flow injection autoanalyzer
Lachat/Zellweger Analytics QuikChem 8000 flow injection autoanalyzer
PI Supplied Instrument Name: Lachat/Zellweger Analytics QuikChem 8000 flow injection autoanalyzer PI Supplied Instrument Description:Nitrate/nitrite (NO3- / NO2-) concentration was determined using a Lachat/Zellweger Analytics QuikChem 8000 flow injection autoanalyzer (Milwaukee, WI, USA) using method FIA 31-107-04-1-C.
Ammonium (NH4+) concentration was determined using a Lachat/Zellweger Analytics QuikChem 8000 flow injection autoanalyzer (Milwaukee, WI) using method FIA 31-107-06-1-A/B.
Total dissolved nitrogen (TDN) was measured by in-line digestion using the Lachat/Zellweger Analytics QuikChem 8000 flow injection autoanalyzer (Milwaukee, WI, USA) using method FIA 31-107-04-3-B for low total nitrogen for brackish/fresh waters (detection level: 0.1 - 5.0 milligrams nitrogen per liter).
Orthophosphate (PO43-) was determined using a Lachat/Zellweger Analytics QuikChem 8000 flow injection autoanalyzer (Milwaukee, WI) using method FIA 31-115-01-1-F/G. Instrument Name: Nutrient Autoanalyzer Instrument Short Name:Nutrient Autoanalyzer Instrument Description: Nutrient Autoanalyzer is a generic term used when specific type, make and model were not specified. In general, a Nutrient Autoanalyzer is an automated flow-thru system for doing nutrient analysis (nitrate, ammonium, orthophosphate, and silicate) on seawater samples. Community Standard Description: http://vocab.nerc.ac.uk/collection/L05/current/LAB04/
Shimadzu TOC-5000A Analyzer
Shimadzu TOC-5000A Analyzer
PI Supplied Instrument Name: Shimadzu TOC-5000A Analyzer PI Supplied Instrument Description:Dissolved organic carbon (DOC) concentration was measured using a Shimadzu TOC-5000A Analyzer: Water samples were vacuum filtered (less than 25 kilopascal) using pre-combusted Whatman glass microfibre filters (GF/F). The filtrate was stored in pre-combusted glass scintillation vials with Teflon closures and frozen at -20 degrees Celsius until analysis. The Shimadzu TOC-5000A Analyzer uses high temperature catalytic oxidation followed by non-dispersive infrared analysis of the CO2 produced. Samples were acidified to a pH less than 2 and sparged with air before they were analyzed for non-volatile organic carbon. DOC values in 1996 were run from previously run nutrient samples. Starting February 2018, all stations were collected. Prior to Feb. 2018 only NR 0, 30, 70, 100, 120, and 160 surface and bottom stations were measured. Instrument Name: UV Spectrophotometer-Shimadzu Instrument Short Name:UV Spectrophotometer-Shimadzu Instrument Description: The Shimadzu UV Spectrophotometer is manufactured by Shimadzu Scientific Instruments (ssi.shimadzu.com). Shimadzu manufacturers several models of spectrophotometer; refer to dataset for make/model information. Community Standard Description: http://vocab.nerc.ac.uk/collection/L05/current/LAB20/
secchi disk
secchi disk
PI Supplied Instrument Name: secchi disk PI Supplied Instrument Description:The secchi disk was deployed off of the sunlit side of the research vessel. The depth (in meters) at which the secchi disk was no longer visible by the naked eye was recorded as the secchi depth. Instrument Name: Secchi Disc Instrument Short Name:Secchi Disc Instrument Description: Typically, a 16 inch diameter white/black quadrant disc used to measure water optical clarity Community Standard Description: http://vocab.nerc.ac.uk/collection/L22/current/TOOL0430/
PE 2400 Series II CHNS/O Analyzer
PE 2400 Series II CHNS/O Analyzer
PI Supplied Instrument Name: PE 2400 Series II CHNS/O Analyzer PI Supplied Instrument Description: After drying at 60 0C, the filters were rolled in tin disks and injected into a PE 2400 Series II CHNS/O Analyzer calibrated with acetanilide ending in June 2014. Starting on the Neuse River sample date of June 2, 2014, a Costech Analytical Technologies, Inc. Elemental Combustion System CHNS-O ECS 4010 was used for elemental analysis by "flash combustion/chromatographic separation and multi-detector techniques". The Costech Instrument utilizes EAS Clarity Software. Atropine standards are used to develop a calibration curve (C 70.56%, N 4.84%, and carbon response ratio of 0.025 +/-0.003). NIST Buffalo River Sediment Reference Material 8704 (C 3.351% +/-0.017, N 0.20% +/-0.04) and/or Acetanilide Bypass (C 71.09%, N 10.36%, carbon response ratio of 0.055 +/- 0.003) may used for calibration or a check standard. Instrument Name: CHN Elemental Analyzer Instrument Short Name:CHN_EA Instrument Description: A CHN Elemental Analyzer is used for the determination of carbon, hydrogen, and nitrogen content in organic and other types of materials, including solids, liquids, volatile, and viscous samples.
Hydrolab Data Sonde 3
Hydrolab Data Sonde 3
PI Supplied Instrument Name: Hydrolab Data Sonde 3 PI Supplied Instrument Description:Prior to the 09/13/2000 sampling date, in situ measurements were performed at discrete depths using a Hydrolab Data Sonde 3 equipped with a multiprobe and SVR3 display logger. Instrument Name: HydroLab DataSonde Instrument Short Name: Instrument Description: Hydrolab DataSonde Multiparameter Probes have sensors for temperature, conductivity, salinity, specific conductance, TDS, pH, ORP, dissolved oxygen, turbidity, chlorophyll a, blue-green algae, Rhodamine WT, ammonium, nitrate, chloride, ambient light (PAR), and total dissolved gas.
Yellow Springs Instruments (YSI Incoporated, Ohio) multiparameter sonde (Model 6600 or 6600 EDS-S Extended Deployment System)
Yellow Springs Instruments (YSI Incoporated, Ohio) multiparameter sonde (Model 6600 or 6600 EDS-S Extended Deployment System)
PI Supplied Instrument Name: Yellow Springs Instruments (YSI Incoporated, Ohio) multiparameter sonde (Model 6600 or 6600 EDS-S Extended Deployment System) PI Supplied Instrument Description:Beginning on the 09/13/2000 sampling date, in situ measurements were performed at discrete depths on the sunlit side of the research vessel using a Yellow Springs Instruments (YSI Incoporated, Ohio) multiparameter sonde (Model 6600 or 6600 EDS-S Extended Deployment System) equipped with a YSI conductivity/temperature probe (Model 6560), a YSI chlorophyll probe (Model 6025), a YSI pH probe (Model 6561 or 6566), a YSI pulsed dissolved oxygen probe (Model 6562), a self cleaning YSI turbidity probe (Model 6026 or 6136), and beginning on the 07/30/2003 sampling date, a flat Li-Cor sensor (UWQ-PAR 6067). Instrument Name: YSI Sonde 6-Series Instrument Short Name:YSI Sonde 6-Series Instrument Description: YSI 6-Series water quality sondes and sensors are instruments for environmental monitoring and long-term deployments. YSI datasondes accept multiple water quality sensors (i.e., they are multiparameter sondes). Sondes can measure temperature, conductivity, dissolved oxygen, depth, turbidity, and other water quality parameters. The 6-Series includes several models. More from YSI. Community Standard Description: http://vocab.nerc.ac.uk/collection/L22/current/TOOL0737/
Turner Designs TD-700 fluorometer
Turner Designs TD-700 fluorometer
PI Supplied Instrument Name: Turner Designs TD-700 fluorometer PI Supplied Instrument Description:Colored dissolved organic matter (CDOM) was measured using a Turner Designs TD-700 fluorometer configured with a near-UV mercury vapour lamp, a 350 nm excitation filter, and a 410–600 nm emission filter. Instrument Name: Turner Designs 700 Laboratory Fluorometer Instrument Short Name:TD-700 Instrument Description: The TD-700 Laboratory Fluorometer is a benchtop fluorometer designed to detect fluorescence over the UV to red range. The instrument can measure concentrations of a variety of compounds, including chlorophyll-a and fluorescent dyes, and is thus suitable for a range of applications, including chlorophyll, water quality monitoring and fluorescent tracer studies. Data can be output as concentrations or raw fluorescence measurements. Community Standard Description: http://vocab.nerc.ac.uk/collection/L22/current/TOOL0510/
in-line photodiode array spectrophotometer
in-line photodiode array spectrophotometer
PI Supplied Instrument Name: in-line photodiode array spectrophotometer PI Supplied Instrument Description:Diagnostic phytoplankton photopigments were identified, separated and quantified by high performance liquid chromatography coupled to an in-line photodiode array spectrophotometer (Jeffrey et al. 1997) Instrument Name: Spectrophotometer Instrument Short Name:Spectrophotometer Instrument Description: An instrument used to measure the relative absorption of electromagnetic radiation of different wavelengths in the near infra-red, visible and ultraviolet wavebands by samples. Community Standard Description: http://vocab.nerc.ac.uk/collection/L05/current/LAB20/
plastic Van Dorn sampler
plastic Van Dorn sampler
PI Supplied Instrument Name: plastic Van Dorn sampler PI Supplied Instrument Description:Bottom water samples were collected with a horizontal plastic Van Dorn sampler. Instrument Name: Van Dorn water sampler Instrument Short Name: Instrument Description: A free-flushing water sample bottle comprising a cylinder (polycarbonate, acrylic or PVC) with a stopper at each end. The bottle is closed by means of a messenger from the surface releasing the tension on a latex band and thus pulling the two stoppers firmly into place. A thermometer can be mounted inside the bottle. One or more bottles can be lowered on a line to allow sampling at a single or multiple depth levels. Van Dorn samplers are suitable for for physical (temperature), chemical and biological sampling in shallow to very deep water. Bottles are typically lowered vertically through the water column although a horizontal version is available for sampling near the seabed or at thermoclines or chemoclines. Because of the lack of metal parts the bottles are suitable for trace metal sampling, although the blue polyurethane seal used in the Alpha version may leach mercury. The Beta version uses white ASA plastic seals that do not leach mercury but are less durable.