[{"dataset_parameter_nid":"769454","supplied_name":"cruise_no","supplied_units":"integer","value_format":null,"description":"\u003Cp\u003Enumber of CARIACO cruise\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":null,"parameter_nid":"1073","parameter_description":"\u003Cp\u003EAn association with a community-wide standard parameter has not yet been made.\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":null,"parameter_official_name":"no_bcodmo_term","parameter_external_identifier":null,"parameter_short_description":"No BCO-DMO term","parameter_short_name":"no_bcodmo_term","parameter_units":null,"parameter_units_external_identifier":null,"order":null,"types":[{"type":"profile","rank":"1","dataset_parameter_type_nid":"769488","type_rankable":"1","type_tid":"16"},{"type":"aggregate values","dataset_parameter_type_nid":"769489","type_rankable":"0","type_tid":"28"}]},{"dataset_parameter_nid":"769455","supplied_name":"Cruise_ID1","supplied_units":"alphanumeric","value_format":null,"description":"\u003Cp\u003Ecruise ID for OCB\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"1073","parameter_description":"\u003Cp\u003EAn association with a community-wide standard parameter has not yet been made.\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":null,"parameter_official_name":"no_bcodmo_term","parameter_external_identifier":null,"parameter_short_description":"No BCO-DMO term","parameter_short_name":"no_bcodmo_term","parameter_units":null,"parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"769456","supplied_name":"Cruise_ID2","supplied_units":"alphanumeric","value_format":null,"description":"\u003Cp\u003Ecruise ID for the CARIACO project\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"1073","parameter_description":"\u003Cp\u003EAn association with a community-wide standard parameter has not yet been made.\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":null,"parameter_official_name":"no_bcodmo_term","parameter_external_identifier":null,"parameter_short_description":"No BCO-DMO term","parameter_short_name":"no_bcodmo_term","parameter_units":null,"parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"769457","supplied_name":"Year","supplied_units":"unitless","value_format":null,"description":"\u003Cp\u003Eyear of sampling\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"1062","parameter_description":"\u003Cp\u003Eyear, reported as YYYY, e.g. 1995\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":"nd","parameter_official_name":"year","parameter_external_identifier":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/YEARXXXX\/","parameter_short_description":"year","parameter_short_name":"year","parameter_units":null,"parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"769458","supplied_name":"Month","supplied_units":"unitless","value_format":null,"description":"\u003Cp\u003Emonth of sampling\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"1115","parameter_description":"\u003Cp\u003EMonth of year; numeric 1 to 12.\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":"nd","parameter_official_name":"month","parameter_external_identifier":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/MNTHXXXX\/","parameter_short_description":"month of year","parameter_short_name":"month","parameter_units":"dimensionless","parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"769459","supplied_name":"Day","supplied_units":"unitless","value_format":null,"description":"\u003Cp\u003Eday of sampling\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"1113","parameter_description":"\u003Cp\u003Eday of month; numeric 1 to 31\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":"nd","parameter_official_name":"day","parameter_external_identifier":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/DAYXXXXX\/","parameter_short_description":"day of month","parameter_short_name":"day","parameter_units":"dimensionless","parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"769460","supplied_name":"Date","supplied_units":"unitless","value_format":null,"description":"\u003Cp\u003Edate of sampling (local time)\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"1070","parameter_description":"\u003Cp\u003Edate; generally reported in GMT as YYYYMMDD (year; month; day); also as MMDD (month; day); EqPac dates are local Hawaii time. ISO_Date format is YYYY-MM-DD (\u003Ca href=\u0022http:\/\/www.iso.org\/iso\/home\/standards\/iso8601.htm\u0022 target=\u0022_blank\u0022\u003Ehttp:\/\/www.iso.org\/iso\/home\/standards\/iso8601.htm\u003C\/a\u003E)\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":null,"parameter_official_name":"date","parameter_external_identifier":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/ADATAA01\/","parameter_short_description":"date","parameter_short_name":"date","parameter_units":null,"parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"769461","supplied_name":"press","supplied_units":"decibars","value_format":null,"description":"\u003Cp\u003Epressure from CTD\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"732","parameter_description":"\u003Cp\u003Ewater pressure at measurement; depth reported as pressure; positive number increasing with water depth\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":"nd","parameter_official_name":"pressure","parameter_external_identifier":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/PRESPR01\/","parameter_short_description":"water pressure","parameter_short_name":"press","parameter_units":"various","parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"769462","supplied_name":"depth","supplied_units":"meters","value_format":null,"description":"\u003Cp\u003Edepth from CTD\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"808","parameter_description":"\u003Cp\u003EObservation\/sample depth below the sea surface. Units often reported as: meters, feet.\u003C\/p\u003E\n\u003Cp\u003E\nWhen used in a JGOFS\/GLOBEC dataset the depth is a best estimate; usually but not always calculated from pressure; calculated either from CTD pressure using Fofonoff and Millard (1982; UNESCO Tech Paper #44) algorithm adjusted for 1980 equation of state for seawater (EOS80) or simply equivalent to nominal depth as recorded during sampling if CTD pressure was unavailable.\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":"nd","parameter_official_name":"depth","parameter_external_identifier":"http:\/\/vocab.nerc.ac.uk\/collection\/P09\/current\/DEPH\/","parameter_short_description":"depth","parameter_short_name":"depth","parameter_units":"various","parameter_units_external_identifier":null,"order":null,"types":[{"type":"Primary depth variable","dataset_parameter_type_nid":"769477","type_rankable":"0","type_tid":"22"}]},{"dataset_parameter_nid":"769463","supplied_name":"temp","supplied_units":"degrees Celsius","value_format":null,"description":"\u003Cp\u003Etemperature from CTD ITS-90\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"733","parameter_description":"\u003Cp\u003Ewater temperature at measurement depth\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":null,"parameter_official_name":"temperature","parameter_external_identifier":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/TEMPP901\/","parameter_short_description":"water temperature at measurement depth","parameter_short_name":"temp","parameter_units":"degrees Celsius, ITS 90","parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"769464","supplied_name":"sal","supplied_units":"PSU","value_format":null,"description":"\u003Cp\u003Esalinity from CTD PSS-78 (PSU)\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"955","parameter_description":"\u003Cp\u003ESalinity: The amount (mass or quantity of matter) of salt per amount (volume or mass) of a body of water.\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":null,"parameter_official_name":"sal","parameter_external_identifier":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/PSALST01\/","parameter_short_description":"salinity","parameter_short_name":"sal","parameter_units":"dimensionless","parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"769465","supplied_name":"potemp","supplied_units":"degrees Celsius","value_format":null,"description":"\u003Cp\u003Epotential temperature ITS-90\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"936","parameter_description":"\u003Cp\u003Epotential temperature (International Practical Temperature Scale - 68 ,or 90). When known, the scale will be reported in the units field of the documentation file.\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":null,"parameter_official_name":"potemp","parameter_external_identifier":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/POTMCV01\/","parameter_short_description":"potential temperature","parameter_short_name":"potemp","parameter_units":"degrees Celsius","parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"769466","supplied_name":"sigma_t","supplied_units":"kilograms\/meter^3","value_format":null,"description":"\u003Cp\u003Edensity sigma-t\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"734","parameter_description":"\u003Cp\u003ESigma-t density, often reported in kg\/m^3 - 1000. \u0027Sigma-t\u0027 is density minus 1000 (without the effect of pressure). It is normally calculated from observations of temperature and salinity. (See \u003Ca href=\u0022http:\/\/globec.whoi.edu\/globec-dir\/sea_water_density_description.html\u0022 target=\u0022_blank\u0022\u003EHow do we measure the density of sea water?\u003C\/a\u003E)\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":"nd","parameter_official_name":"sigma-t","parameter_external_identifier":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/SIGTEQST\/","parameter_short_description":"sigma-t","parameter_short_name":"sigma_t","parameter_units":"various","parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"769467","supplied_name":"sigma_0","supplied_units":"kilograms\/meter^3","value_format":null,"description":"\u003Cp\u003Esigma theta (potential density)\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"971","parameter_description":"\u003Cp\u003Esigma-theta (potential density), often reported in kg\/m^3. Sigma-theta is denoted \u0027sigma_0\u0027, where the last digit, a zero, is used to represent the Greek letter theta. This altered density which takes into account adiabatic heating\/cooling with changes in pressure is called the \u0027potential density\u0027. (See \u003Ca href=\u0022http:\/\/globec.whoi.edu\/globec-dir\/sea_water_density_description.html\u0022 target=\u0022_blank\u0022\u003EHow do we measure the density of sea water?\u003C\/a\u003E)\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":"nd","parameter_official_name":"sigma_0","parameter_external_identifier":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/SIGTPR01\/","parameter_short_description":"sigma-theta","parameter_short_name":"sigma_0","parameter_units":"various","parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"769468","supplied_name":"O2_ml_L","supplied_units":"milliliters\/liter","value_format":null,"description":"\u003Cp\u003Eoxygen dissolved from SBE 43 CTD\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"1198","parameter_description":"\u003Cp\u003EOxygen; dissolved; reported in units of milliliters\/liter\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":"nd","parameter_official_name":"O2_ml_L","parameter_external_identifier":null,"parameter_short_description":"dissolved Oxygen","parameter_short_name":"O2_ml_L","parameter_units":"milliliters\/liter","parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"769469","supplied_name":"beam_cp","supplied_units":"1\/meter","value_format":null,"description":"\u003Cp\u003Eparticulate beam attenuation\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"1147","parameter_description":"\u003Cp\u003Eattenuation (loss of light) of a narrow, well collimated beam of light;  beam attenuation due to particles;  the particulate beam attenuation coefficient (cp)\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":"nd","parameter_official_name":"beam_cp","parameter_external_identifier":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/ATTNZZ01\/","parameter_short_description":"beam attenuation","parameter_short_name":"beam_cp","parameter_units":"1\/m","parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"769470","supplied_name":"beam_att","supplied_units":"1\/meter","value_format":null,"description":"\u003Cp\u003Ebeam attenuation coefficient\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"1147","parameter_description":"\u003Cp\u003Eattenuation (loss of light) of a narrow, well collimated beam of light;  beam attenuation due to particles;  the particulate beam attenuation coefficient (cp)\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":"nd","parameter_official_name":"beam_cp","parameter_external_identifier":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/ATTNZZ01\/","parameter_short_description":"beam attenuation","parameter_short_name":"beam_cp","parameter_units":"1\/m","parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"769471","supplied_name":"fluor_CTD","supplied_units":"RFU","value_format":null,"description":"\u003Cp\u003ECTD relative fluorescence\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"835","parameter_description":"\u003Cp\u003EFluorescence. Indirect measure of pigment concentration.\u003C\/p\u003E\n\u003Cp\u003EUnits and collection method may vary. Units often reported in\u00a0milligrams\/meter^3 (mg\/m3) or micromoles per liter (ug\/L). Sometimes reported after being calibrated against extracted pigment concentrations.\u003C\/p\u003E\n\u003Cp\u003EIn JGOFS\/GLOBEC projects\u00a0fluorescence is measured from CTD instrument sensor.\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":null,"parameter_official_name":"fluorescence","parameter_external_identifier":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/CPHLPM01\/","parameter_short_description":"fluorescence","parameter_short_name":"fluor","parameter_units":"various","parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"769472","supplied_name":"fluor_chla","supplied_units":"micrograms\/meter^3","value_format":null,"description":"\u003Cp\u003Efluorescence rescaled units are numerically equivalent to chlorophyll-a concentrations\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"766","parameter_description":"\u003Cp\u003ETotal chlorophyll a pigment. See dataset for units of measurement; often reported in:\u00a0milligrams per cubic meter (mg\/m3); micrograms\/liter (ug\/L); nanograms\/liter\u00a0(ng\/L).\u003C\/p\u003E\n\u003Cp\u003ECAUTION Within JGOFS MERGED water column products: this parameter is derived from HPLC methodology and the units are nanograms\/liter; however; this parameter name is also used for a variety of water and nonwater column sampling; derived via the fluorometric method; units will also vary.\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":null,"parameter_official_name":"chlorophyll a","parameter_external_identifier":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/CPHLHPP1\/","parameter_short_description":"chlorophyll a","parameter_short_name":"chl_a","parameter_units":"various","parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"769473","supplied_name":"Latitude","supplied_units":"decimal degrees","value_format":null,"description":"\u003Cp\u003Elatitude with positive values indicating North\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"730","parameter_description":"\u003Cp\u003Elatitude, in decimal degrees, North is positive, negative denotes South; Reported in some datasets as degrees, minutes\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":"nd","parameter_official_name":"latitude","parameter_external_identifier":"http:\/\/vocab.nerc.ac.uk\/collection\/P09\/current\/LATX\/","parameter_short_description":"latitude","parameter_short_name":"lat","parameter_units":"decimal degrees","parameter_units_external_identifier":null,"order":null,"types":[{"type":"Primary latitude variable","dataset_parameter_type_nid":"769475","type_rankable":"0","type_tid":"23"}]},{"dataset_parameter_nid":"769474","supplied_name":"Longitude","supplied_units":"decimal degrees","value_format":null,"description":"\u003Cp\u003Elongitude with positive values indicating East\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"731","parameter_description":"\u003Cp\u003Elongitude, in decimal degrees, East is positive, negative denotes West; Reported in some datsets as degrees, minutes\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":"nd","parameter_official_name":"longitude","parameter_external_identifier":"http:\/\/vocab.nerc.ac.uk\/collection\/P09\/current\/LONX\/ ","parameter_short_description":"longitude","parameter_short_name":"lon","parameter_units":"decimal degrees","parameter_units_external_identifier":null,"order":null,"types":[{"type":"Primary longitude variable","dataset_parameter_type_nid":"769476","type_rankable":"0","type_tid":"24"}]}]