[{"dataset_parameter_nid":"773804","supplied_name":"sample_id","supplied_units":"unitless","value_format":null,"description":"\u003Cp\u003ESample ID\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"960","parameter_description":"\u003Cp\u003Eunique sample identification or number; any combination of alpha numeric characters; precise definition is file dependent\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":null,"parameter_official_name":"sample","parameter_external_identifier":"http:\/\/vocab.nerc.ac.uk\/collection\/P02\/current\/ACYC\/","parameter_short_description":"sample identification","parameter_short_name":"sample","parameter_units":"dimensionless","parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"773805","supplied_name":"sample_date","supplied_units":"unitless","value_format":null,"description":"\u003Cp\u003EDate sample measured\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"1070","parameter_description":"\u003Cp\u003Edate; generally reported in GMT as YYYYMMDD (year; month; day); also as MMDD (month; day); EqPac dates are local Hawaii time. ISO_Date format is YYYY-MM-DD (\u003Ca href=\u0022http:\/\/www.iso.org\/iso\/home\/standards\/iso8601.htm\u0022 target=\u0022_blank\u0022\u003Ehttp:\/\/www.iso.org\/iso\/home\/standards\/iso8601.htm\u003C\/a\u003E)\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":null,"parameter_official_name":"date","parameter_external_identifier":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/ADATAA01\/","parameter_short_description":"date","parameter_short_name":"date","parameter_units":null,"parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"773806","supplied_name":"days","supplied_units":"unitless","value_format":null,"description":"\u003Cp\u003EDays of incubation in day-month-year\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"473067","parameter_description":"\u003Cp\u003EDays as in days spent sampling or days post treatment for sampling\u003C\/p\u003E\n","parameter_max_value":"","parameter_min_value":"","parameter_nd_value":"nd","parameter_official_name":"days","parameter_external_identifier":"","parameter_short_description":"days","parameter_short_name":"days","parameter_units":"days","parameter_units_external_identifier":"","order":null},{"dataset_parameter_nid":"773807","supplied_name":"growth","supplied_units":"unitless","value_format":null,"description":"\u003Cp\u003ETime point of experiment\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"1073","parameter_description":"\u003Cp\u003EAn association with a community-wide standard parameter has not yet been made.\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":null,"parameter_official_name":"no_bcodmo_term","parameter_external_identifier":null,"parameter_short_description":"No BCO-DMO term","parameter_short_name":"no_bcodmo_term","parameter_units":null,"parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"773808","supplied_name":"label_time_rep","supplied_units":"unitless","value_format":null,"description":"\u003Cp\u003EExtra sample information\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"1073","parameter_description":"\u003Cp\u003EAn association with a community-wide standard parameter has not yet been made.\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":null,"parameter_official_name":"no_bcodmo_term","parameter_external_identifier":null,"parameter_short_description":"No BCO-DMO term","parameter_short_name":"no_bcodmo_term","parameter_units":null,"parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"773809","supplied_name":"bottle_nr","supplied_units":"unitless","value_format":null,"description":"\u003Cp\u003EIncubation bottle number\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"1107","parameter_description":"\u003Cp\u003Erosette Niskin bottle number\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":"nd","parameter_official_name":"bot","parameter_external_identifier":null,"parameter_short_description":"bottle number","parameter_short_name":"bot","parameter_units":"unitless","parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"773810","supplied_name":"raw_invivo_flu","supplied_units":"arbitrary","value_format":null,"description":"\u003Cp\u003ERaw in vivo fluorescence\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"835","parameter_description":"\u003Cp\u003EFluorescence. Indirect measure of pigment concentration.\u003C\/p\u003E\n\u003Cp\u003EUnits and collection method may vary. Units often reported in\u00a0milligrams\/meter^3 (mg\/m3) or micromoles per liter (ug\/L). Sometimes reported after being calibrated against extracted pigment concentrations.\u003C\/p\u003E\n\u003Cp\u003EIn JGOFS\/GLOBEC projects\u00a0fluorescence is measured from CTD instrument sensor.\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":null,"parameter_official_name":"fluorescence","parameter_external_identifier":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/CPHLPM01\/","parameter_short_description":"fluorescence","parameter_short_name":"fluor","parameter_units":"various","parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"773811","supplied_name":"bact_abund","supplied_units":"cells per mL","value_format":null,"description":"\u003Cp\u003EBacteria Abundance\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"735","parameter_description":"\u003Cp\u003EAmount (number, mass, diversity\/species variation) of the specific taxa\/group counted per unit area or volume\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":"nd","parameter_official_name":"abundance","parameter_external_identifier":"http:\/\/vocab.nerc.ac.uk\/collection\/P03\/current\/B070\/","parameter_short_description":"abundance ","parameter_short_name":"abundance","parameter_units":"various","parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"773812","supplied_name":"doc","supplied_units":"micromoles per Liter (umol\/L)","value_format":null,"description":"\u003Cp\u003Edissolved organic carbon\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":null,"parameter_nid":"1188","parameter_description":"\u003Cp\u003Edissolved organic Carbon\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":"nd","parameter_official_name":"DOC","parameter_external_identifier":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/CORGZZZX\/","parameter_short_description":"dissolved organic Carbon","parameter_short_name":"DOC","parameter_units":"various","parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"773813","supplied_name":"dom_b","supplied_units":"quinine sulfate units","value_format":null,"description":"\u003Cp\u003EDOM fluorescence peak B\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"835","parameter_description":"\u003Cp\u003EFluorescence. Indirect measure of pigment concentration.\u003C\/p\u003E\n\u003Cp\u003EUnits and collection method may vary. Units often reported in\u00a0milligrams\/meter^3 (mg\/m3) or micromoles per liter (ug\/L). Sometimes reported after being calibrated against extracted pigment concentrations.\u003C\/p\u003E\n\u003Cp\u003EIn JGOFS\/GLOBEC projects\u00a0fluorescence is measured from CTD instrument sensor.\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":null,"parameter_official_name":"fluorescence","parameter_external_identifier":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/CPHLPM01\/","parameter_short_description":"fluorescence","parameter_short_name":"fluor","parameter_units":"various","parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"773814","supplied_name":"dom_t","supplied_units":"quinine sulfate units","value_format":null,"description":"\u003Cp\u003EDOM fluorescence peak T\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"835","parameter_description":"\u003Cp\u003EFluorescence. Indirect measure of pigment concentration.\u003C\/p\u003E\n\u003Cp\u003EUnits and collection method may vary. Units often reported in\u00a0milligrams\/meter^3 (mg\/m3) or micromoles per liter (ug\/L). Sometimes reported after being calibrated against extracted pigment concentrations.\u003C\/p\u003E\n\u003Cp\u003EIn JGOFS\/GLOBEC projects\u00a0fluorescence is measured from CTD instrument sensor.\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":null,"parameter_official_name":"fluorescence","parameter_external_identifier":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/CPHLPM01\/","parameter_short_description":"fluorescence","parameter_short_name":"fluor","parameter_units":"various","parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"773815","supplied_name":"dom_a","supplied_units":"quinine sulfate units","value_format":null,"description":"\u003Cp\u003EDOM fluorescence peak A\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"835","parameter_description":"\u003Cp\u003EFluorescence. Indirect measure of pigment concentration.\u003C\/p\u003E\n\u003Cp\u003EUnits and collection method may vary. Units often reported in\u00a0milligrams\/meter^3 (mg\/m3) or micromoles per liter (ug\/L). Sometimes reported after being calibrated against extracted pigment concentrations.\u003C\/p\u003E\n\u003Cp\u003EIn JGOFS\/GLOBEC projects\u00a0fluorescence is measured from CTD instrument sensor.\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":null,"parameter_official_name":"fluorescence","parameter_external_identifier":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/CPHLPM01\/","parameter_short_description":"fluorescence","parameter_short_name":"fluor","parameter_units":"various","parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"773816","supplied_name":"dom_c","supplied_units":"quinine sulfate units","value_format":null,"description":"\u003Cp\u003EDOM fluorescence peak C\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"835","parameter_description":"\u003Cp\u003EFluorescence. Indirect measure of pigment concentration.\u003C\/p\u003E\n\u003Cp\u003EUnits and collection method may vary. Units often reported in\u00a0milligrams\/meter^3 (mg\/m3) or micromoles per liter (ug\/L). Sometimes reported after being calibrated against extracted pigment concentrations.\u003C\/p\u003E\n\u003Cp\u003EIn JGOFS\/GLOBEC projects\u00a0fluorescence is measured from CTD instrument sensor.\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":null,"parameter_official_name":"fluorescence","parameter_external_identifier":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/CPHLPM01\/","parameter_short_description":"fluorescence","parameter_short_name":"fluor","parameter_units":"various","parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"773817","supplied_name":"dom_m","supplied_units":"quinine sulfate units","value_format":null,"description":"\u003Cp\u003EDOM fluorescence peak M\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"835","parameter_description":"\u003Cp\u003EFluorescence. Indirect measure of pigment concentration.\u003C\/p\u003E\n\u003Cp\u003EUnits and collection method may vary. Units often reported in\u00a0milligrams\/meter^3 (mg\/m3) or micromoles per liter (ug\/L). Sometimes reported after being calibrated against extracted pigment concentrations.\u003C\/p\u003E\n\u003Cp\u003EIn JGOFS\/GLOBEC projects\u00a0fluorescence is measured from CTD instrument sensor.\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":null,"parameter_official_name":"fluorescence","parameter_external_identifier":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/CPHLPM01\/","parameter_short_description":"fluorescence","parameter_short_name":"fluor","parameter_units":"various","parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"773818","supplied_name":"dom_n","supplied_units":"quinine sulfate units","value_format":null,"description":"\u003Cp\u003EDOM fluorescence peak N\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"835","parameter_description":"\u003Cp\u003EFluorescence. Indirect measure of pigment concentration.\u003C\/p\u003E\n\u003Cp\u003EUnits and collection method may vary. Units often reported in\u00a0milligrams\/meter^3 (mg\/m3) or micromoles per liter (ug\/L). Sometimes reported after being calibrated against extracted pigment concentrations.\u003C\/p\u003E\n\u003Cp\u003EIn JGOFS\/GLOBEC projects\u00a0fluorescence is measured from CTD instrument sensor.\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":null,"parameter_official_name":"fluorescence","parameter_external_identifier":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/CPHLPM01\/","parameter_short_description":"fluorescence","parameter_short_name":"fluor","parameter_units":"various","parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"773819","supplied_name":"dom_bix","supplied_units":"unitless","value_format":null,"description":"\u003Cp\u003EBiological index\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"1073","parameter_description":"\u003Cp\u003EAn association with a community-wide standard parameter has not yet been made.\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":null,"parameter_official_name":"no_bcodmo_term","parameter_external_identifier":null,"parameter_short_description":"No BCO-DMO term","parameter_short_name":"no_bcodmo_term","parameter_units":null,"parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"773820","supplied_name":"dom_hix","supplied_units":"unitless","value_format":null,"description":"\u003Cp\u003EHumificaiton index\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"1073","parameter_description":"\u003Cp\u003EAn association with a community-wide standard parameter has not yet been made.\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":null,"parameter_official_name":"no_bcodmo_term","parameter_external_identifier":null,"parameter_short_description":"No BCO-DMO term","parameter_short_name":"no_bcodmo_term","parameter_units":null,"parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"773821","supplied_name":"dom_a254","supplied_units":"inverse meters","value_format":null,"description":"\u003Cp\u003EDOM absorption coefficient at 254 nm\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"1956","parameter_description":"\u003Cp\u003EThe fraction of incident flux which is absorbed, divided by the thickness of the medium layer.\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":"nd","parameter_official_name":"absorption coefficient","parameter_external_identifier":null,"parameter_short_description":"absorption coefficient","parameter_short_name":"absorption_coefficient","parameter_units":"1\/m","parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"773822","supplied_name":"dom_a300","supplied_units":"inverse meters","value_format":null,"description":"\u003Cp\u003EDOM absorption coefficient at 300 nm\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"1956","parameter_description":"\u003Cp\u003EThe fraction of incident flux which is absorbed, divided by the thickness of the medium layer.\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":"nd","parameter_official_name":"absorption coefficient","parameter_external_identifier":null,"parameter_short_description":"absorption coefficient","parameter_short_name":"absorption_coefficient","parameter_units":"1\/m","parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"773823","supplied_name":"dom_a320","supplied_units":"inverse meters","value_format":null,"description":"\u003Cp\u003EDOM absorption coefficient at 320 nm\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"1956","parameter_description":"\u003Cp\u003EThe fraction of incident flux which is absorbed, divided by the thickness of the medium layer.\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":"nd","parameter_official_name":"absorption coefficient","parameter_external_identifier":null,"parameter_short_description":"absorption coefficient","parameter_short_name":"absorption_coefficient","parameter_units":"1\/m","parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"773824","supplied_name":"dom_slope","supplied_units":"inverse micrometer","value_format":null,"description":"\u003Cp\u003ESlope of DOM absorption from 300 to 650 nm\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"1956","parameter_description":"\u003Cp\u003EThe fraction of incident flux which is absorbed, divided by the thickness of the medium layer.\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":"nd","parameter_official_name":"absorption coefficient","parameter_external_identifier":null,"parameter_short_description":"absorption coefficient","parameter_short_name":"absorption_coefficient","parameter_units":"1\/m","parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"773825","supplied_name":"dom_S275_295","supplied_units":"inverse nanometer","value_format":null,"description":"\u003Cp\u003ESlope of DOM absorption from 275 to 295 nm\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"1956","parameter_description":"\u003Cp\u003EThe fraction of incident flux which is absorbed, divided by the thickness of the medium layer.\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":"nd","parameter_official_name":"absorption coefficient","parameter_external_identifier":null,"parameter_short_description":"absorption coefficient","parameter_short_name":"absorption_coefficient","parameter_units":"1\/m","parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"773826","supplied_name":"dom_S350_400","supplied_units":"inverse nanometer","value_format":null,"description":"\u003Cp\u003ESlope of DOM absorption from 350 to 400 nm\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"1956","parameter_description":"\u003Cp\u003EThe fraction of incident flux which is absorbed, divided by the thickness of the medium layer.\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":"nd","parameter_official_name":"absorption coefficient","parameter_external_identifier":null,"parameter_short_description":"absorption coefficient","parameter_short_name":"absorption_coefficient","parameter_units":"1\/m","parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"773827","supplied_name":"dom_SR","supplied_units":"unitless","value_format":null,"description":"\u003Cp\u003ERatio of S275-295 to S350-400\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"1073","parameter_description":"\u003Cp\u003EAn association with a community-wide standard parameter has not yet been made.\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":null,"parameter_official_name":"no_bcodmo_term","parameter_external_identifier":null,"parameter_short_description":"No BCO-DMO term","parameter_short_name":"no_bcodmo_term","parameter_units":null,"parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"773828","supplied_name":"BEPOC","supplied_units":"micromoles per Liter (umol\/L)","value_format":null,"description":"\u003Cp\u003Ebase-extracted POC concentration\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":null,"parameter_nid":"934","parameter_description":"\u003Cp\u003EParticulate Organic Carbon. Units may be micrograms\/Liter, milligrams\/Liter or milligrams\/meter^3\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":null,"parameter_official_name":"POC","parameter_external_identifier":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/CORGCAP1\/","parameter_short_description":"particulate organic Carbon (POC)","parameter_short_name":"POC","parameter_units":"various","parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"773829","supplied_name":"bepom_b","supplied_units":"quinine sulfate units","value_format":null,"description":"\u003Cp\u003EBEPOM fluorescence peak B\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"835","parameter_description":"\u003Cp\u003EFluorescence. Indirect measure of pigment concentration.\u003C\/p\u003E\n\u003Cp\u003EUnits and collection method may vary. Units often reported in\u00a0milligrams\/meter^3 (mg\/m3) or micromoles per liter (ug\/L). Sometimes reported after being calibrated against extracted pigment concentrations.\u003C\/p\u003E\n\u003Cp\u003EIn JGOFS\/GLOBEC projects\u00a0fluorescence is measured from CTD instrument sensor.\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":null,"parameter_official_name":"fluorescence","parameter_external_identifier":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/CPHLPM01\/","parameter_short_description":"fluorescence","parameter_short_name":"fluor","parameter_units":"various","parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"773830","supplied_name":"bepom_t","supplied_units":"quinine sulfate units","value_format":null,"description":"\u003Cp\u003EBEPOM fluorescence peak T\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"835","parameter_description":"\u003Cp\u003EFluorescence. Indirect measure of pigment concentration.\u003C\/p\u003E\n\u003Cp\u003EUnits and collection method may vary. Units often reported in\u00a0milligrams\/meter^3 (mg\/m3) or micromoles per liter (ug\/L). Sometimes reported after being calibrated against extracted pigment concentrations.\u003C\/p\u003E\n\u003Cp\u003EIn JGOFS\/GLOBEC projects\u00a0fluorescence is measured from CTD instrument sensor.\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":null,"parameter_official_name":"fluorescence","parameter_external_identifier":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/CPHLPM01\/","parameter_short_description":"fluorescence","parameter_short_name":"fluor","parameter_units":"various","parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"773831","supplied_name":"bepom_a","supplied_units":"quinine sulfate units","value_format":null,"description":"\u003Cp\u003EBEPOM fluorescence peak A\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"835","parameter_description":"\u003Cp\u003EFluorescence. Indirect measure of pigment concentration.\u003C\/p\u003E\n\u003Cp\u003EUnits and collection method may vary. Units often reported in\u00a0milligrams\/meter^3 (mg\/m3) or micromoles per liter (ug\/L). Sometimes reported after being calibrated against extracted pigment concentrations.\u003C\/p\u003E\n\u003Cp\u003EIn JGOFS\/GLOBEC projects\u00a0fluorescence is measured from CTD instrument sensor.\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":null,"parameter_official_name":"fluorescence","parameter_external_identifier":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/CPHLPM01\/","parameter_short_description":"fluorescence","parameter_short_name":"fluor","parameter_units":"various","parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"773832","supplied_name":"bepom_c","supplied_units":"quinine sulfate units","value_format":null,"description":"\u003Cp\u003EBEPOM fluorescence peak C\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"835","parameter_description":"\u003Cp\u003EFluorescence. Indirect measure of pigment concentration.\u003C\/p\u003E\n\u003Cp\u003EUnits and collection method may vary. Units often reported in\u00a0milligrams\/meter^3 (mg\/m3) or micromoles per liter (ug\/L). Sometimes reported after being calibrated against extracted pigment concentrations.\u003C\/p\u003E\n\u003Cp\u003EIn JGOFS\/GLOBEC projects\u00a0fluorescence is measured from CTD instrument sensor.\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":null,"parameter_official_name":"fluorescence","parameter_external_identifier":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/CPHLPM01\/","parameter_short_description":"fluorescence","parameter_short_name":"fluor","parameter_units":"various","parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"773833","supplied_name":"bepom_m","supplied_units":"quinine sulfate units","value_format":null,"description":"\u003Cp\u003EBEPOM fluorescence peak M\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"835","parameter_description":"\u003Cp\u003EFluorescence. Indirect measure of pigment concentration.\u003C\/p\u003E\n\u003Cp\u003EUnits and collection method may vary. Units often reported in\u00a0milligrams\/meter^3 (mg\/m3) or micromoles per liter (ug\/L). Sometimes reported after being calibrated against extracted pigment concentrations.\u003C\/p\u003E\n\u003Cp\u003EIn JGOFS\/GLOBEC projects\u00a0fluorescence is measured from CTD instrument sensor.\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":null,"parameter_official_name":"fluorescence","parameter_external_identifier":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/CPHLPM01\/","parameter_short_description":"fluorescence","parameter_short_name":"fluor","parameter_units":"various","parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"773834","supplied_name":"bepom_n","supplied_units":"quinine sulfate units","value_format":null,"description":"\u003Cp\u003EBEPOM fluorescence peak N\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"835","parameter_description":"\u003Cp\u003EFluorescence. Indirect measure of pigment concentration.\u003C\/p\u003E\n\u003Cp\u003EUnits and collection method may vary. Units often reported in\u00a0milligrams\/meter^3 (mg\/m3) or micromoles per liter (ug\/L). Sometimes reported after being calibrated against extracted pigment concentrations.\u003C\/p\u003E\n\u003Cp\u003EIn JGOFS\/GLOBEC projects\u00a0fluorescence is measured from CTD instrument sensor.\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":null,"parameter_official_name":"fluorescence","parameter_external_identifier":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/CPHLPM01\/","parameter_short_description":"fluorescence","parameter_short_name":"fluor","parameter_units":"various","parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"773835","supplied_name":"bepom_bix","supplied_units":"unitless","value_format":null,"description":"\u003Cp\u003EBiological index\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"1073","parameter_description":"\u003Cp\u003EAn association with a community-wide standard parameter has not yet been made.\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":null,"parameter_official_name":"no_bcodmo_term","parameter_external_identifier":null,"parameter_short_description":"No BCO-DMO term","parameter_short_name":"no_bcodmo_term","parameter_units":null,"parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"773836","supplied_name":"bepom_hix","supplied_units":"unitless","value_format":null,"description":"\u003Cp\u003EHumificaiton index\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"1073","parameter_description":"\u003Cp\u003EAn association with a community-wide standard parameter has not yet been made.\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":null,"parameter_official_name":"no_bcodmo_term","parameter_external_identifier":null,"parameter_short_description":"No BCO-DMO term","parameter_short_name":"no_bcodmo_term","parameter_units":null,"parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"773837","supplied_name":"bepom_a254","supplied_units":"inverse meters","value_format":null,"description":"\u003Cp\u003EBEPOM absorption coefficient at 254 nm\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"1956","parameter_description":"\u003Cp\u003EThe fraction of incident flux which is absorbed, divided by the thickness of the medium layer.\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":"nd","parameter_official_name":"absorption coefficient","parameter_external_identifier":null,"parameter_short_description":"absorption coefficient","parameter_short_name":"absorption_coefficient","parameter_units":"1\/m","parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"773838","supplied_name":"bepom_a300","supplied_units":"inverse meters","value_format":null,"description":"\u003Cp\u003EBEPOM absorption coefficient at 300 nm\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"1956","parameter_description":"\u003Cp\u003EThe fraction of incident flux which is absorbed, divided by the thickness of the medium layer.\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":"nd","parameter_official_name":"absorption coefficient","parameter_external_identifier":null,"parameter_short_description":"absorption coefficient","parameter_short_name":"absorption_coefficient","parameter_units":"1\/m","parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"773839","supplied_name":"bepom_a320","supplied_units":"inverse meters","value_format":null,"description":"\u003Cp\u003EBEPOM absorption coefficient at 320 nm\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"1956","parameter_description":"\u003Cp\u003EThe fraction of incident flux which is absorbed, divided by the thickness of the medium layer.\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":"nd","parameter_official_name":"absorption coefficient","parameter_external_identifier":null,"parameter_short_description":"absorption coefficient","parameter_short_name":"absorption_coefficient","parameter_units":"1\/m","parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"773840","supplied_name":"bepom_slope","supplied_units":"inverse micrometer","value_format":null,"description":"\u003Cp\u003ESlope of BEPOM absorption from 300 to 650 nm\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"1956","parameter_description":"\u003Cp\u003EThe fraction of incident flux which is absorbed, divided by the thickness of the medium layer.\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":"nd","parameter_official_name":"absorption coefficient","parameter_external_identifier":null,"parameter_short_description":"absorption coefficient","parameter_short_name":"absorption_coefficient","parameter_units":"1\/m","parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"773841","supplied_name":"bepom_S275_295","supplied_units":"inverse nanometer","value_format":null,"description":"\u003Cp\u003ESlope of BEPOM absorption from 275 to 295 nm\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"1956","parameter_description":"\u003Cp\u003EThe fraction of incident flux which is absorbed, divided by the thickness of the medium layer.\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":"nd","parameter_official_name":"absorption coefficient","parameter_external_identifier":null,"parameter_short_description":"absorption coefficient","parameter_short_name":"absorption_coefficient","parameter_units":"1\/m","parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"773842","supplied_name":"bepom_S350_400","supplied_units":"inverse nanometer","value_format":null,"description":"\u003Cp\u003ESlope of BEPOM absorption from 350 to 400 nm\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"1956","parameter_description":"\u003Cp\u003EThe fraction of incident flux which is absorbed, divided by the thickness of the medium layer.\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":"nd","parameter_official_name":"absorption coefficient","parameter_external_identifier":null,"parameter_short_description":"absorption coefficient","parameter_short_name":"absorption_coefficient","parameter_units":"1\/m","parameter_units_external_identifier":null,"order":null},{"dataset_parameter_nid":"773843","supplied_name":"bepom_SR","supplied_units":"unitless","value_format":null,"description":"\u003Cp\u003ERatio of S275-295 to S350-400\u003C\/p\u003E\n","no_data_value":"nd","conversion_necessary":"no","conversion_utility":"","parameter_nid":"1073","parameter_description":"\u003Cp\u003EAn association with a community-wide standard parameter has not yet been made.\u003C\/p\u003E\n","parameter_max_value":null,"parameter_min_value":null,"parameter_nd_value":null,"parameter_official_name":"no_bcodmo_term","parameter_external_identifier":null,"parameter_short_description":"No BCO-DMO term","parameter_short_name":"no_bcodmo_term","parameter_units":null,"parameter_units_external_identifier":null,"order":null}]