Parameter: fluorescence counts

Short Description: fluorescence counts
Short Name: flr
Official Name: fluorescence counts
Units: counts

Description

Output of a WetLabs fluorometer passed through a MetraByte A/D converter to convert the 0-5 volt dc fluorometer output to serial (count) data. The MetraByte device sets the output decimal point as necessary for best resolution, which results in a 1 volt dc fluorometer value being represented as +01000.00 in the raw MetraByte serial stream. (from Calliope metadata file KN207-01)

DatasetPI-Supplied DescriptionPI-Supplied Name
Experimental results describing copepod gut evacuation time from species collected in the San Francisco estuary during 2013fluorescence value fluorescence
Experimental results describing the minimum time for copepod gut fluorescence by plate reader method analyzed at San Francisco State University during 2013fluorescence value fluorescence
Experimental results describing if sonication is needed for chlorophyll extraction by copepods in the San Francisco estuary conducted during 2013fluorescence of blank control samples fluor_blank
Experimental results describing if sonication is needed for chlorophyll extraction by copepods in the San Francisco estuary conducted during 2013fluorescence of non-sonicated samples fluor_no_soni
Experimental results describing if sonication is needed for chlorophyll extraction by copepods in the San Francisco estuary conducted during 2013fluorescence of samples manually daubed with sonicator probe but not sonicated fluor_probe
Experimental results describing if sonication is needed for chlorophyll extraction by copepods in the San Francisco estuary conducted during 2013fluorescence of sonicated samples fluor_sonic
Alongtrack data collected continuously by the ship's underway acquisition system from R/V Knorr cruise KN207-01 in the southern tip of Nova Scotia to Bermuda in 2012 (SargassoSeaLipids project)Fluorescence measured by WetLabs Wet-Star fluorometer located in the Hydro Lab clean seawater piping. Measured in volts dc converted to MetraByte serial (count) data. 1 volt dc = +0100.00 counts. flr
Alongtrack data collected continuously by the ship's underway acquisition system from R/V Knorr cruise KN207-03 in the North Atlantic (transect from Ponta Delgada, Azores to Reykjavik, Iceland) in 2012 (NA-VICE project)Fluorescence measured by WetLabs Wet-Star fluorometer located in the Hydro Lab clean seawater piping. Measured in volts dc converted to MetraByte serial (count) data. 1 volt dc = +0100.00 counts. flr
Cross shelf undulating towed vehicle (Acrobat with MIDAS) survey data from R/V Pelican PE08-54, PE10-01, PE09-12 in the Northwest Florida shelf off Panama City, FL. from 2008-2009 (BenDiM project)Wetlabs raw counts fl_counts
Alongtrack data collected continuously by the ship's underway acquisition system from R/V Oceanus OC473 in the western North Atlantic, 35-50 degrees North in 2011 (OAPS project)Fluorescence measured by WetLabs Wet-Star fluorometer located in the Wet Lab clean seawater piping. Units are counts (1 volt dc = 1000). FLR
Alongtrack data from RV/Tioga cruise TI668, full water-column to the Wilkinson Basin, Gulf of Maine, May 2013 (Gulf of Maine Pteropods project, GoME OA Pteropods project)Fluorescence measured by WetLabs Wet-Star fluorometer located in the Wet Lab clean seawater piping. Units are counts (1 volt dc = 1000). flr
Alongtrack data from RV/Tioga cruise TI700 to the Gulf of Maine, August 2013 (Gulf of Maine Pteropods project)Fluorescence measured by WetLabs Wet-Star fluorometer located in the Wet Lab clean seawater piping. Units are counts (1 volt dc = 1000). flr
Alongtrack data from RV/Tioga cruise TI715 to the Gulf of Maine, October 2013 (Gulf of Maine Pteropods project)Fluorescence measured by WetLabs Wet-Star fluorometer located in the Wet Lab clean seawater piping. Units are counts (1 volt dc = 1000). flr
Alongtrack data from R/V Tioga TI725 in the Gulf of Maine from January 2014 (Gulf of Maine Pteropods project)Fluorescence measured by WetLabs Wet-Star fluorometer located in the Wet Lab clean seawater piping. Units are counts (1 volt dc = 1000). flr
Alongtrack data from R/V Tioga TI729 in the Gulf of Maine from January 2014 (Gulf of Maine Pteropods project)Fluorescence measured by WetLabs Wet-Star fluorometer located in the Wet Lab clean seawater piping. Units are counts (1 volt dc = 1000). flr
Alongtrack data from RV/Tioga cruise TI746 to the Gulf of Maine, April 2014 (Gulf of Maine Pteropods project)Fluorescence measured by WetLabs Wet-Star fluorometer located in the Wet Lab clean seawater piping. Units are counts (1 volt dc = 1000). flr