A laboratory instrument used for quantifying organic elements. It can measure C, H, N and S and optionally O, Cl and TIC. It was first developed in 2006 as a successor to the vario EL III. It uses a high-temperature combustion unit that is able to complete sample digestion at up to 1200 deg C (or 1800 deg C at the point of combustion when tin foil is used) and a jet injection of oxygen directly to the sample during combustion. Separation of gas components are performed on up to 3 gas-selective columns which trap gases until they are heated up and the prior gas peak has reached the baseline during detection. It uses a Thermal Conductivity Detector (TCD) as standard. An infrared (IR) detector for sulfur and oxygen and electrochemical detector for chlorine are optionally available. The instrument can measure C / N elemental ratios of up to 12,000:1 and provides an elemental detection limit of < 40 ppm (TCD).
Dataset Name | PI-Supplied Description | PI-Supplied Name |
---|---|---|
Size fractionated organic carbon and nitrogen concentration and stable isotopes from water column of the East Pacific Rise in April 2019 on the R/V Atlantis cruise AT42-09 | UC Davis Stable Isotope Facility did the C and N analysis utilizing an Elemental Analyzer (Elementar Vario EL Cube) attached to an Isotope Ratio Mass Spectrometer (Isoprim VisION). | |
Suspended Organic Particle concentration and stable C and N isotopes (collected with McClane Pumps and GF/F filters) from the Eastern Tropical North Pacific on the R/V Thompson cruise TN278 in April 2012 | UC Davis Stable Isotope Facility (Davis, CA) analysed for C and N utilizing an elemental analyzer (Elementar Vario EL Cube) attached to an isotope ratio mass spectrometer (Isoprim VisION). | |
Suspended Organic Particle concentration and stable C and N isotopes from the Eastern Tropical North Pacific in April 2018 (R/V Roger Revelle RR1805) and October 2019 (R/V Kilo Moana KM1920) | At the UC Davis Stable Isotope Facility (Davis, CA), they used an elemental analyzer (Elementar Vario EL Cube) attached to an isotope ratio mass spectrometer (Isoprim VisION). | |
Size fractionated organic C and N concentrations and stable isotopes from the Eastern Tropical North Pacific on the R/V Kilo Moana cruise KM1920 in October 2019 | At the UC Davis Stable Isotope Facility samples were analyzed utilizing an Elemental Analyzer (Elementar Vario EL Cube) attached to an Isotope Ratio Mass Spectrometer (Isoprim VisION). | |
Polyphosphate and associated measurements from water and particulate samples collected from 13 locations in the Great Lakes in July-Aug 2018 on R/V Blue Heron cruise BH18-09 | Particulate carbon and nitrogen (PC and PN) were analyzed by using an Elemental Analyzer | CHNS Elemental Analyzer (Vario EL Cube, Elementar) |