These data are from laboratory barite–fluid isotope-tracer experiments conducted with synthetic barite and natural pelagic barite in artificial seawater and filtered seawater. Experiments were performed as a four-condition matrix combining two fluid types and two barite types, and measured the temporal evolution of the 138Ba:136Ba ratio in filtered fluid samples over 174 days. Filtered seawater was collected from Vineyard Sound, Massachusetts, and the natural pelagic barite was isolated from Equ...
Views
Downloads
These numbers come from web analytics and reflect real user activity on the site. Download counts include both page-based interactions and direct file downloads. They reliably show dataset usage and are mostly free of bot traffic.
Laboratory barite–fluid isotope-tracer experiments were conducted in the NIRVANA Labs at the Woods Hole Oceanographic Institution. A four-condition matrix combined two fluid types, artificial seawater and filtered seawater from Vineyard Sound, Massachusetts, with two barite types, synthetic barium sulfate and natural pelagic barite isolated from Equatorial Pacific sediments. Artificial seawater was prepared following Smith & Chanley (1975) and adjusted to approximately pH 8.1 with concentrated potassium hydroxide. Filtered seawater was collected using the flow-through seawater system at the Environmental Systems Laboratory at the Woods Hole Oceanographic Institution (Huguenin, 1975), collected into 1 liter acid-washed high-density polyethylene bottles, and filtered through a 0.4 micrometer acid-washed polyethersulfone membrane in a clean room. Synthetic barite was Alfa Aesar barium sulfate powder, Lot 24177, and natural pelagic barite was isolated from Equatorial Pacific sediments. Known quantities of barite powder were added to each fluid and kept under constant agitation for up to six months. In each experiment, the dissolved pool was amended with a 136Ba-enriched solution such that the initial fluid 138Ba:136Ba ratio was approximately 0.35 ± 0.03 (±2 standard error, n = 4). Barium-136 additions were adjusted to achieve an initial barite saturation state of 1.3, calculated using PHREEQC. Aliquots of 2 milliliters were sampled over 174 days and filtered through a 0.22 micrometer polyethersulfone membrane filter prior to analysis of the fluid 138Ba:136Ba ratio.
Same experiment series
Same experiment series
Horner, T. J., Middleton, J. (2026). Barium isotope tracer experiment results from natural and synthetic barite–fluid laboratory equilibration experiments in artificial and filtered seawater. Biological and Chemical Oceanography Data Management Office (BCO-DMO). (Version 1) Version Date 2026-08-12 [if applicable, indicate subset used]. http://lod.bco-dmo.org/id/dataset/1004882 [access date]
Terms of Use
This dataset is licensed under Creative Commons Attribution 4.0.
If you wish to use this dataset, it is highly recommended that you contact the original principal investigators (PI). Should the relevant PI be unavailable, please contact BCO-DMO (info@bco-dmo.org) for additional guidance. For general guidance please see the BCO-DMO Terms of Use document.