Water Sampling
Discrete water samples collected during two Octopus Odyssey expeditions aboard R/V Falkor (too) in June (FKT230602) and December (FKT231202) 2023. The data consists mainly of near-the-surface sampling events, with some take from the bottom at Dorado Outcrop and Pampa Submarina, hydrothermally active areas off Costa Rica’s Pacific margin.
Discrete water samples were collected from 12 L Niskin bottles (24 Niskin bottles-CTD rosette) and in situ physicochemical parameters (temperature, salinity) were measured with CTD.
Laboratory analyses
Carbonate chemistry
Carbonate chemistry samples were collected first, as soon as the Niskin bottle was opened and before any other samples (e.g., phytoplankton, nutrients, microplastics, etc.) The sampling order was 1) dissolved inorganic carbon (DIC) and 2) total alkalinity (TA). DIC and TA samples were collected, poisoned and stored following procedures from SOP 3b (Dickson et al. 2007) and REMARCO-AO-P-01 (Sánchez-Noguera 2021). Water was collected from the Niskin bottle using a Tygon tubing. The water flow was constant during the process of rinsing the sample containers/syringes (x3) to remove bubbles from the draw Tygon tubing. Samples were stored in the dark at 4 ºC until analysis at Centro de Investigación en Ciencias del Mar y Limnología (CIMAR-UCR). NOTE: TA is not included in Version 1 of this dataset. The dataset will be updated when the results are available.
DIC: water was slowly drawn from the Niskin with a 60 mL syringe plugged into the Tygon tube. Sample from the syringe was filtered through a 0.45-micron filter and transferred with a smaller Tygon tube into a 40 mL amber borosilicate vial (acid-washed and combusted), rinsed three times with the sample. Sample was poisoned with 50 µL of saturated HgCl2 and vial closed with PTFE septum.
TA: 250 mL borosilicate bottles with glass stopper were rinsed (3x) with flowing water and filled directly from the Niskin. Each bottle was allowed to overflow approximately 1.5 times the filling time. Headspace was adjusted with a plastic syringe (10 mL), sample was poisoned with 100 µL of saturated HgCl2 and bottle sealed with a greased stopper (Apiezon-L). NOTE: TA is not included in Version 1 of this dataset. The dataset will be updated when the results are available.
Nutrients
Water was collected from the Niskin with a 60 mL syringe plugged into the Tygon tube. Sample from the syringe was filtered through a 0.45-micron filter and transferred with a smaller Tygon tube to a 60 mL plastic vial, rinsed three times with the filtered sample. Samples were frozen and stored at -20 ºC until analysis.