A device that collects an in-situ discrete water sample from any depth and returns it to the surface without contamination by the waters through which it passes, such as a water bottle.
| Dataset Name | PI-Supplied Description | PI-Supplied Name |
|---|---|---|
| 16S rRNA gene amplicon sequences metadata collected from water samples and biofilms on mineral substrates deployed in the Lau Basin (Tonga) during R/V Thompson cruise TN401 from Mar to Apr 2022 | We sequenced the 16S V4 hypervariable region of deep-water samples collected with a Suspended Particulate Rosette Sampler (SuPR) (Mclane Research Laboratories, Inc. Falmouth, MA USA) or Universal Fluid Obtainer (UFO) (National Deep Submergence Facility, Falmouth, MA, USA). | Suspended Particulate Rosette Sampler (SuPR) or Universal Fluid Obtainer (UFO) |
| Under the ice bacterial cultures and genome sequences from the R/V Kronprins Haakon in the Arctic Ocean from May 18 to 21, 2023 | Hydro-Bios 2 L water sampler | |
| Description of Axial Seamount hydrothermal sampling sites from 5 cruises to the Axial Seamount, Juan de Fuca Ridge from 2012 to 2015 (NeMO2015 project) | Pumps vent fluid through a titanium nozzle and records the temperature of the fluid within the intake nozzle once every second during pumping. http://www.pmel.noaa.gov/edd/hydrothermal-fluid-and-particle-sampler | NOAA Hydrothermal Fluid and Particle Sampler |
| Environmental data from experimental aquaria during a laboratory experiment testing the effects of pH, light availability and biotic interaction on coralline algae calcification and productivity at the Sitka Sound Science Center in 2017 | To monitor treatment conditions, we used a handheld meter (YSI) to take daily temperature readings in the replicate aquaria and measure salinity of incoming seawater daily just upstream of our experimental system. YSI handheld meter used to measure dissolved oxygen, pH, salinity, and temperature. | YSI handheld meter |
| Chemistry from discrete samples of hydrothermal springs sampled by the HOV Alvin during R/V Atlantis cruise AT26-24 at Dorado Outcrop in December of 2014 | syringe sample taken by Alvin | |
| Dissolved trace metal concentrations, nickel speciation, and pH in shipboard incubations conducted on FeOA project cruise SKQ202209S on the R/V Sikuliaq between June 4 2022 to July 1 2022 in the NE Pacific. | Seawater for the incubations was collected with a custom surface sampling system, “towfish” (Mellett and Buck 2020), comprised of acid cleaned Bev-A-Line-IV tubing and an Almatec Double PTFE Diaphragm Pump. | Towfish |
| Flow cytometry data from Incurrent and Excurrent flow samples collected from shallow artificial reef sponges and seawater in the Florida Keys, USA from Apr 2021 to Aug 2021 | One milliliter of seawater samples were collected via VacuSIP and preserved in paraformaldehyde (0.5% final concentration), flash frozen in liquid nitrogen, and then shipped to Bigelow Laboratory for Ocean Sciences. | VacuSIP |
| Metabarcoding data from microbial diversity survey at Axial Seamount aboard the R/V Thompson cruise TN420 in Jul 2022 and Jul 2023 | Collection of diffuse vent fluid and nearby seawater (background) was conducted using the Universal Fluid Obtainer (UFO) and the SUPR sampler. | Universal Fluid Obtainer (UFO) and the SUPR sampler |
| Metabarcoding data from microbial diversity survey at Axial Seamount aboard the R/V Thompson cruise TN420 in Jul 2022 and Jul 2023 | A subset of samples from a prior year's expedition to Axial Seamount (TN405) was also included in the analysis. During TN405 (July 2022), one ROV Jason dive collected diffuse vent fluid using the Hydrothermal Fluid and Particle Sampler (labeled "HFS" in the dataset; designed by David Butterfield) and seawater from the plume was collected via Niskin bottles during CTD casts. | Hydrothermal Fluid and Particle Sampler |
| Discrete sample measurements of dissolved oxygen, dissolved inorganic carbon, and total alkalinity from the Seven Mile Island Innovation Laboratory (SMIIL) from Aug 2022 to Jun 2024 | During field maintenance trips that included discrete sample collection, samples were collected at the last measurement before removal of instruments for maintenance and again upon first available measurement once the sensors were re-deployed.Sample bottles were held by hand under ~0.2 m of seawater for 30 seconds to equilibrate with surrounding seawater before capping. | Sample bottles |
| Spring 2012 - d13C and d2H Stable Isotope Composition | Collection Type: Point Water sampler (PWS), Grab Core, Gravity Core, Drill Core | Point Water sampler (PWS) |
| Dissolved Macronutrient Concentrations from Depth Profiles and Incubation Experiments from STING I Cruise AE2305 on R/V Atlantic Explorer in the Gulf of Mexico from February to March 2023 | Seawater samples were collected with a custom surface sampling system, “towfish” (Mellett and Buck 2020), comprised of acid cleaned Bev-A-Line-IV tubing and an Almatec Double PTFE Diaphragm Pump. | Towfish |
| Dissolved trace metal and macronutrient concentration data from incubation experiments conducted during the May 2021 EXPORTS North Atlantic cruise (DY131) | Seabird SBE 32 trace metals frame and rosette sampling system were used for depth profile sample collection. | Seabird SBE 32 |
| Depth profiles of oceanographic parameters in spring and summer from R/V Terrapin, R/V Hugh R. Sharp multiple cruises in Chesapeake Bay, 2010-2011 (LiDZ project) | Samples were collected at 7 depths across the oxycline using a syringe-sampling device that simultaneously fills a total of 28 syringes (4 syringes every 20cm vertically) using a mechanical feature that gradually pulls the water into the syringes when triggered. In 2012, a new “oxycline sampling device” was developed that uses a multi-channel peristaltic pump to draw water from 8 depths across a 3m range. | oxycline sampling device |