This dataset includes the concentrations of in-situ dissolved (< 0.2 micrometers (μm)) and soluble (< 0.02 μm) iron, iron bound to electroactive humic-like substances, total electroactive iron-binding humic-like substances, and total organic iron-binding ligands from discrete depth profile samples collected on the NBP16-08 cruise on the R/V IB Nathaniel B. Palmer in the Southern Ocean on 10 October 2016. This project investigates the impact of iron-binding humic-like substances and total iron...
Views
Downloads
These numbers come from web analytics and reflect real user activity on the site. Download counts include both page-based interactions and direct file downloads. They reliably show dataset usage and are mostly free of bot traffic.
Water column sampling:
The full water column at the site named Station 21 in the Drake Passage was sampled on 10 October 2016 aboard the R/V IB Nathaniel B. Palmer. 12-liter (L) Niskin bottles (OceanTestEquipment, Inc.) mounted on a trace metal clean rosette sampling system (SBE32, Seabird; TMC CTD) were used to collect depth profile samples.
Samples for dissolved humic-like substances, total dissolved organic iron-binding ligands, and dissolved iron were filtered through pre-cleaned 0.2-micrometer (µm) polyethersulfone membrane filters (Acropak 200, Pall Corporation) from the trace metal clean rosette (Sterling et al., 2023). Samples for soluble humic-like substances, soluble total organic iron-binding ligands, and soluble iron were additionally filtered through 0.02 µm filters (Anopore; Fitzsimmons and Boyle 2014) on a custom vacuum filtration setup (Burns et al., 2023). Prior to sample collection, each 0.02 µm filter was rinsed with three ~50-milliliter (mL) aliquots of Milli-Q (18.2 MW cm) followed by three ~30-mL rinses with the seawater sample; a new filter was used for each sample. Humic-like substance and total organic ligand samples were collected in acid-cleaned, narrow mouth 500 mL fluorinated high-density polyethylene bottles (FLPE; Nalgene) and stored at -20 degrees Celsius (ºC) until shore-based analyses at Oregon State University. Samples for iron were collected into 125 mL acid-cleaned low-density polyethylene bottles (LDPE; Nalgene), acidified to 0.024 M final concentration with ultrapure hydrochloric acid (HCl; Optima, Fisher), then stored at room temperature prior to shore-based analysis.
Sample analyses – dissolved and soluble humic-like substances:
Electroactive, Fe-binding humic-like substances were measured using adsorptive cathodic stripping voltammetry based on the method first developed by Laglera et al. (2007), updated by Sukekava et al. (2018), and described in Moore et al. (in review). Samples were analyzed using a polarographic 797 VA Computrace (Metrohm) stand equipped with a hanging mercury drop electrode, Ag/AgCl reference electrode, platinum rod auxiliary electrode, and an acid-cleaned Teflon analytical cell. Briefly, frozen samples were set out to thaw overnight at room temperature in the dark. The following day, samples were inverted several times to homogenize, and 10 mL sub-samples were aliquoted into each of 2 paired acid-cleaned, pre-conditioned 50 mL polypropylene vials (MetalFree, Labcon). Boric acid buffer (7.5 mM final concentration; Mahieu et al., 2024) was added to maintain a solution pH of 8.2. Iron standard was added into vial "B" (final concentration 60 nanomolar (nM)) to saturate all the Fe-binding ligands in the solution, whereas vial A remained with ambient Fe conditions. Vial A represented the ambient concentration of Fe bound to humic-like substances in situ, and vial B represented the total concentration of Fe-binding electroactive ligands in the sample. Both aliquots were left to equilibrate for a minimum of 14 hours.
After the equilibration period, vial A was added to the Teflon voltametric cell with an addition of 500 microliters (μL) of 0.4M KBrO₃⁻ catalyst. The sample was then purged for 300 seconds with high-purity N₂ gas, and then electrochemical analysis was performed with a 60-120 second deposition period with stirring at -0.1 volts (V) followed by linear sweep voltammetry (-0.1 to -1V, scan rate 50 millivolts per second (mV s⁻¹)). Vial B was analyzed immediately following vial A under the same conditions and deposition time, then three successive standard additions of Fe-saturated Suwannee River Fulvic Acid (SRFA, International Humic Substance Society #2S101F) standard were added. Default standard additions were 0.1, 0.2, and 0.3 mg SRFA per liter. A 70 s N₂ purge was included after each addition to ensure oxygen removal. Triplicate scans were performed for all measurements. Teflon analytical cell and polypropylene vials were rinsed thoroughly with Milli-Q water between samples to minimize carryover.
Peak heights were extracted from scans using ECDSOFT software (Omanović, 2025; Omanović and Branica, 1998). The peak heights from vial A and vial B were converted into ambient Fe-bound humic-like substance and total Fe-binding humic-like substance concentrations, respectively in μg SRFA eq per liter using the slope of curve generated by the three standard additions. Units were then converted to nM Fe eq using the measured binding capacity of SRFA in seawater 14.6 ± 0.7 nmol Fe mg⁻¹ SRFA (Sukekava et al., 2018).
Sample analyses: dissolved and soluble iron:
Dissolved and soluble Fe measurements were performed as described in Lagerström et al., (2013) and Burns et al., (2023). Trace metal analyses were performed using an automated SeaFAST pico in line with a Thermo Scientific iCAP-RQ Quadrupole CCT ICP-MS. Quantification was performed with external nine-point calibration curves and matrix match. Subsamples of internal standards and reference materials were measured at each run including NASS-7 (consensus Fe = 6.29 ± 0.47 nM; measured value = 5.19 ± 0.44 nM, n = 14), GSC (consensus Fe = 2.07 nM; measured value = 1.97 ± 0.02 nM, n = 3), SAFE D1 (consensus Fe = 0.69 ± 0.04 nM; measured value = 0.61 ± 0.00 nM, n = 3), SAFE D2 (consensus Fe = 0.96 ± 0.02 nM; measured value = 1.03 ± 0.02 nM, n = 3)
The detection limit for Fe was determined from three times the standard deviation of replicate lowest standards and was equivalent to 0.048 nM.
Sample analyses: dissolved and soluble total organic iron-binding ligands:
Samples were analyzed using competitive ligand exchange-adsorptive cathodic stripping voltammetry (CLE-adCSV; Buck et al., 2012, 2007; Mahieu et al., 2024; Rue and Bruland, 1995). The samples were thawed overnight at room temperature in the dark prior to analysis. Thawed samples were inverted several times to homogenize, then 10 mL was aliquoted into each of 16 conditioned tubes (50 mL, MetalFree, Labcon) along with 7.5 millimolar (mM) boric acid-ammonium hydroxide buffer (Mahieu et al., 2024). Iron standard (prepared by dilution of atomic absorption spectrometry grade, AA; Fisher Chemical™ in 0.024 M trace metal grade HCl) was then added to aliquots to final concentrations 0, 0, 0.1, 0.25, 0.5, 0.75, 1, 1.5, 2, 2.5, 3, 4, 5, 7.5, 10, and 15 nM. After at least 2 hours of equilibration, salycilaldoxime (98 + %, TCI America™) solution made in methanol (LC/MS Grade Optima, Fisher Chemical™) was added to each vial for a final concentration of 25 micromolar (µM) and left to equilibrate for at least 15 minutes before analysis.
Aliquots were analyzed in a fluorinated ethylene propylene cell (FEP; Princeton Applied Research) on a controlled mercury growth electrode (CGME) from BioAnalytical Systems, Inc. (BASi) equipped with a platinum wire counter electrode, a Ag/AgCl reference electrode, and quadruple-distilled elemental mercury (Bethlehem Apparatus) as working electrode. Analyses were run in Static Mercury Drop Electrode (SMDE) mode with a size 14 drop. The CGME was controlled by an EClipse potentiostat (BASi) or an Epsilon Ɛ2 electrochemical analyzer (BASi; 2 systems were used simultaneously). The following parameters were applied through the software EpsilonEC (BASi): differential pulse adsorptive cathodic stripping voltammetry (DP-AdCSV), deposition at +0.05 V while stirring, 15 seconds of equilibration (no stirring), stripping from 0 to -0.85 V with a 6 mV step, 50 mV amplitude, 35 milliseconds (ms) pulse width, and 200 ms pulse period (Mahieu et al., 2024).
The reduction peak heights were determined using an automated procedure presented in Mahieu et al. (2024). Briefly, the 4ᵗʰ derivative of the scan was produced through the software ECDSoft (Omanović and Branica, 1998), and then the peak height was defined using a linear baseline on the adaptive scan. The peak heights were then compiled in a custom-made Excel spreadsheet, and the data fitted on the software ProMCC (Omanović et al., 2015) using complete complexation fitting model and detection window αAL of 79 e.g. Buck et al. (2007).
Buck, K. N., Moore, L. E., Mahieu, L., Caprara, S., Freiberger, R. B., Chappell, P. D., Jenkins, B. D. (2026). Size-fractionated Fe speciation. Biological and Chemical Oceanography Data Management Office (BCO-DMO). (Version 1) Version Date 2026-10-23 [if applicable, indicate subset used]. http://lod.bco-dmo.org/id/dataset/1010687 [access date]
Terms of Use
This dataset is licensed under Creative Commons Attribution 4.0.
If you wish to use this dataset, it is highly recommended that you contact the original principal investigators (PI). Should the relevant PI be unavailable, please contact BCO-DMO (info@bco-dmo.org) for additional guidance. For general guidance please see the BCO-DMO Terms of Use document.